Delta ASDA-A+ Servo Drive Alarm Codes & Diagnostic Guide
Complete alarm code reference directory, trip causes, and step-by-step diagnostic procedures for the Delta ASDA-A+ high-power AC servo drive series. Search or filter through the complete alarm code directory below.
Power Range
3.0 – 7.5 kW (4 – 10 HP)
Supply Voltage
200–230V AC (3-Phase)
Control Modes
Position (Pt/Pr), Speed, Torque
Operator Interface
Integrated 5-Digit 7-Segment Keypad
Complete Delta ASDA-A+ Servo Drive Alarm Code Directory
Use the search box in the table below to quickly find your alarm code (e.g., type AL001, AL003, or Overcurrent).
| Fault Code and Meaning | Cause and Remedy |
|---|---|
| ALE01 Overcurrent | Cause:
Remedy:
|
| ALE02 Overvoltage | Cause:
Remedy:
|
| ALE03 Undervoltage | Cause:
Remedy:
|
| ALE05 Regeneration error | Cause:
Remedy:
|
| ALE06 Overload | Cause:
Remedy:
|
| ALE07 Overspeed | Cause:
Remedy:
|
| ALE08 Abnormal pulse control command | Cause:
Remedy:
|
| ALE09 Excessive deviation | Cause:
Remedy:
|
| ALE10 Watch dog execution time out | Cause:
Remedy:
|
| ALE11 Encoder error (Position detector fault) | Cause:
Remedy:
|
| ALE12 Adjustment error | Cause:
Remedy:
|
| ALE13 Emergency stop activated | Cause:
Remedy:
|
| ALE14 Reverse (CWL) limit switch error | Cause:
Remedy:
|
| ALE15 Forward (CCWL) limit switch error | Cause:
Remedy:
|
| ALE16 IGBT temperature error | Cause:
Remedy:
|
| ALE17 Memory error | Cause: Data error in Memory read-out / write-in. Remedy: If the error does not clear after resetting the power supply, please contact your distributor for assistance or contact with Delta. |
| ALE18 DSP communication error | Cause: Control power is in error. Remedy: If the error does not clear after resetting the power supply, please contact your distributor for assistance or contact with Delta. |
| ALE19 Serial communication error | Cause:
Remedy:
|
| ALE20 Serial communication time out | Cause:
Remedy:
|
| ALE21 Command write-in error | Cause: Control power is in error. Remedy: If the error does not clear after resetting the power supply, please contact your distributor for assistance or contact with Delta. |
| ALE22 Input power phase loss | Cause: Control power supply is in error. Remedy: If the fault does not clear even when the three-phase power is connected correctly, please contact your distributor for assistance or contact with Delta. |
| ALE23 Pre-overload warning | Cause: The drive is going to overload. Remedy:
|
| ALE97 Internal command execution time out | Cause: An error occurs when internal command is executing. Remedy: If the error does not clear after resetting the power supply, please contact your distributor for assistance or contact with Delta. |
| ALE98 DSP communication error | Cause: Maybe the hardware is damaged. Remedy: If the error does not clear after resetting the power supply, please contact your distributor for assistance or contact with Delta. |
| ALE99 DSP communication error | Cause: Maybe the hardware is damaged. Remedy: If the error does not clear after resetting the power supply, please contact your distributor for assistance or contact with Delta. |
| ALE04 "Mismatch" error | Cause: The type of the servo motor is incorrect. Remedy: Repair or replace the servo drive or the servo motor. |
| ALE24 Encoder error (Position detector fault) | Cause: Maybe the Encoder is damaged. Remedy: If the error does not clear after resetting the power supply, please contact your distributor for assistance or contact with Delta. |
| ALE25 Encoder error (Position detector fault) | Cause: The servo drive automatically detect the servo motor is in error. Remedy:
|
How to Clear & Reset Delta ASDA-A+ Servo Drive Alarms
- Digital Input Reset (ARST): Apply a momentary contact pulse to the external digital input configured as ARST (Alarm Reset, function code 0x02) via parameters P2-10 to P2-17 for at least 100 milliseconds.
- Keypad Reset: Diagnose and resolve the cause of the alarm trip, navigate to parameter P0-01 on the front 5-digit LED keypad, and enter value 1 (or execute the keypad reset sequence) to clear the error.
- Delta ASDA-Soft PC Tool: Connect your PC via the RS-232 / RS-485 serial communication port, launch ASDA-Soft, navigate to the Alarm Information / Diagnostics tab, and click “Clear Alarm”.
- Modbus Serial Reset: Transmit an alarm clear command by writing value 0x0001 to parameter address 0001H (P0-01) over the built-in RS-485 / RS-422 Modbus serial communication link.
- Power Cycle: Disconnect AC main circuit line power (R, S, T) and control circuit power (L1c, L2c), wait until the internal CHARGE LED and keypad display turn completely off (approx. 5 minutes for bus capacitor discharge), then restore mains power.
⚠️ High-Voltage Electrical Safety Warning:
Always verify with a calibrated digital multimeter that intermediate DC bus voltage measures strictly below 25VDC across terminals [P+] and [-] (or [P+] and [D]) and ensure that the red CHARGE LED is completely extinguished before opening terminal covers or servicing motor power terminals U, V, and W on the Delta ASDA-A+ servo drive.