Industrial VFD & Drive Fault Code Lookup
Select your drive brand and model below to view troubleshooting guides and fault codes.
Browse VFD Fault Codes by Manufacturer
Select your drive manufacturer to access dedicated fault code lists, error tables, and diagnostic guides
View Full Manufacturer Directory (/brand) →ACS880, ACS580, ACS355, ACH580, ACS150
PowerFlex 525, PowerFlex 753, PowerFlex 755
Commander C200, Unidrive M700, Digitax HD
VLT FC302, FC280, Aqua FC202, Micro FC51
MS300, C2000, VFD-E, CP2000, ME300
VFX48/52, FDU48/52, VSS, VSM Series
FRENIC-Mini, Multi, Ace, FRENIC-MEGA
WJ200, NES1, SJ700D, WL200 Series
MD200, MD310, MD500, CS710 Inverters
Goodrive GD20, GD200A, GD350, GD10
Combivert F5, F6, G6, S6 Servo Drives
Sx2000, Ex2000, Cx2000, Hx2000 Series
i510, i550, 8400 TopLine, 9300 Vector
iG5A, S100, H100, iS7, M100 Inverters
FR-A800, FR-D700, FR-E700, FR-F800
Commander C200, C300, Unidrive M Series
3G3MX2, 3G3RX2, Q2V, Sysmac Drives
Minas A6, VF0, VF-8Z, Compact AC Series
AC10, AC30, 890 Series, 690+ Inverters
Altivar ATV320, ATV630, ATV930, ATV12
Sinamics G120, S120, V20, Micromaster
TOSVERT VF-AS3, VF-S15, VF-nC3, VF-MB1
CFW500, CFW11, CFW700, CFW100
GA700, V1000, A1000, J1000, GA500
Common Industrial Drive Trip Categories
Quick diagnosis guides for universal electrical and mechanical failure modes
⚡ Overcurrent (OC / F0001 / E.OC)
Triggered by short acceleration ramps, jammed motor bearings, sudden load spikes, or internal IGBT transistor damage.
📈 DC Bus Overvoltage (OV / F0002)
Occurs during fast motor deceleration when regeneration pumps voltage back into the DC link. Requires longer decel time or braking resistors.
🌍 Ground / Earth Fault (GF / 2330)
Detects current leakage to protective earth. Often caused by damp motor terminal boxes, degraded cable insulation, or stator winding breakdown.
🔥 Motor Overload (OL / OL1 / 7121)
Continuous operation above rated motor Full Load Amps (FLA). Inspect mechanical gearboxes, cooling fan operation, and thermal sensor wiring.
🌡️ Heatsink Overtemperature (OH / 4310)
Elevated power module temperature resulting from clogged cabinet filters, failed enclosure cooling fans, or excessive carrier switching frequency.
🔌 Input / Output Phase Loss (PHL / 3130)
Loss of a 3-phase supply line or disconnected motor conductor (U, V, W). Check incoming line fuses, disconnect switches, and output contactors.
High-Voltage Electrical Safety Notice
Industrial Variable Frequency Drives operate on hazardous line voltages ranging from 200V to 690VAC. Internal DC bus capacitors can hold lethal charges for up to 15 minutes after line power is disconnected. Always use a calibrated multimeter to verify that DC link voltage is below 50VDC before opening terminal covers or performing insulation resistance (Megger) checks.
Frequently Asked Questions
Expert answers to common inverter diagnostics and fault clearance procedures
How do I clear or reset an industrial VFD fault code?
Most drives can be cleared by pressing the STOP/RESET key on the digital keypad, cycling incoming 3-phase line power, or activating a programmed digital input (DI) reset contact. If the fault persists immediately after clearing, the hardware short circuit, line imbalance, or motor sensor failure remains active.
What is the primary difference between a VFD Warning and a Fault Trip?
A Warning or Alarm indicates that operating parameters (such as heatsink temperature or current limit) are reaching threshold boundaries, but the inverter continues running. A Fault Trip instantly terminates gate pulses to protect IGBT transistors and coasts the motor to a stop.
Why does a VFD trip on DC bus overvoltage during deceleration?
When a motor decelerates faster than mechanical friction allows, the motor turns into a generator and pumps kinetic energy back into the drive’s DC link capacitors. This causes DC bus voltage to exceed safe levels, requiring a longer deceleration ramp or an external dynamic braking resistor.