Industrial VFD & Drive Fault Code Lookup

Select your drive brand and model below to view troubleshooting guides and fault codes.

Common Industrial Drive Trip Categories

Quick diagnosis guides for universal electrical and mechanical failure modes

⚡ Overcurrent (OC / F0001 / E.OC)

Triggered by short acceleration ramps, jammed motor bearings, sudden load spikes, or internal IGBT transistor damage.

📈 DC Bus Overvoltage (OV / F0002)

Occurs during fast motor deceleration when regeneration pumps voltage back into the DC link. Requires longer decel time or braking resistors.

🌍 Ground / Earth Fault (GF / 2330)

Detects current leakage to protective earth. Often caused by damp motor terminal boxes, degraded cable insulation, or stator winding breakdown.

🔥 Motor Overload (OL / OL1 / 7121)

Continuous operation above rated motor Full Load Amps (FLA). Inspect mechanical gearboxes, cooling fan operation, and thermal sensor wiring.

🌡️ Heatsink Overtemperature (OH / 4310)

Elevated power module temperature resulting from clogged cabinet filters, failed enclosure cooling fans, or excessive carrier switching frequency.

🔌 Input / Output Phase Loss (PHL / 3130)

Loss of a 3-phase supply line or disconnected motor conductor (U, V, W). Check incoming line fuses, disconnect switches, and output contactors.

⚠️

High-Voltage Electrical Safety Notice

Industrial Variable Frequency Drives operate on hazardous line voltages ranging from 200V to 690VAC. Internal DC bus capacitors can hold lethal charges for up to 15 minutes after line power is disconnected. Always use a calibrated multimeter to verify that DC link voltage is below 50VDC before opening terminal covers or performing insulation resistance (Megger) checks.

Frequently Asked Questions

Expert answers to common inverter diagnostics and fault clearance procedures

How do I clear or reset an industrial VFD fault code?

Most drives can be cleared by pressing the STOP/RESET key on the digital keypad, cycling incoming 3-phase line power, or activating a programmed digital input (DI) reset contact. If the fault persists immediately after clearing, the hardware short circuit, line imbalance, or motor sensor failure remains active.

What is the primary difference between a VFD Warning and a Fault Trip?

A Warning or Alarm indicates that operating parameters (such as heatsink temperature or current limit) are reaching threshold boundaries, but the inverter continues running. A Fault Trip instantly terminates gate pulses to protect IGBT transistors and coasts the motor to a stop.

Why does a VFD trip on DC bus overvoltage during deceleration?

When a motor decelerates faster than mechanical friction allows, the motor turns into a generator and pumps kinetic energy back into the drive’s DC link capacitors. This causes DC bus voltage to exceed safe levels, requiring a longer deceleration ramp or an external dynamic braking resistor.