Yaskawa Drives Fault Codes & Troubleshooting

Complete diagnostic database for 20 Yaskawa drive series. Browse fault codes, alarms, causes, and step-by-step fixes for industrial AC variable speed inverters and high-performance servo motion amplifiers. Select your drive model series below to access parameter checks, root cause analysis, and physical inspection workflows.

17 AC Inverter Series 3 Servo Motion Drives 20 Total Series

Yaskawa AC Variable Frequency Drives

17 Models
GA800 →

High-Performance Industrial Drive with Advanced Motor Control & Embedded Functional Safety

A1000 →

Premium Full-Featured Vector Control Inverter for Heavy Duty Synchronous & PM Motors

U1000 →

Low-Harmonic Matrix Converter Drive with Direct AC-to-AC Power Regeneration Architecture

G7 →

Heavy Industrial 3-Level Inverter Platform Eliminating Motor Insulation & Bearing Stress

GA500 →

Compact Flexible Industrial Drive for Basic Machine Automation & Integrated Safe Torque Off

V1000 →

Flagship Compact Current Vector Micro Drive for Open-Loop Speed Regulation

D1000 →

Active Regenerative Front-End Converter for Common DC Bus Energy Recovery Systems

E7 →

Dedicated HVAC & Building Automation Inverter Designed for Variable Torque Fans and Pumps

FP605 →

Industrial Fan and Pump Controller with Integrated Bypass and Multiplex Pumping Modes

HV600 →

Dedicated Variable Speed HVAC Drive Featuring BACnet/IP, DriveWizard Mobile & IP55 Options

iQPump Micro →

Compact Micro Intelligent Pump Controller for Agriculture, Booster & Submersible Pumps

iQPump1000 →

Intelligent Multiplex Pump Drive with Integrated Dry-Well, Pipe Fill & Flow Meter Logic

L1000A →

Dedicated Elevator Vector Inverter for Geared & Gearless Traction Machine Control

P1000 →

Custom Industrial Pump Drive Platform for Municipal Water, Wastewater & Slurry Sludge

R1000 →

Regenerative Braking Unit Replacing Dynamic Braking Resistors to Recycle Braking Power

U1000 iQpump →

Ultra-Clean Low-Harmonic Matrix Pumping Controller Operating at Near Unity Power Factor

Z1000 →

Commercial Building HVAC Drive Engineered for Air Handling Units, Chillers & Cooling Towers

Yaskawa AC Servo Drives & Motion Systems

3 Models

Most Common Yaskawa Drive Fault Codes

Diagnostic Quick Reference
Fault Code Servo Alarm Fault Name Common Root Cause
oC A.100 Overcurrent Drive output current exceeded peak rating; rapid acceleration ramp, mechanical load lockup, or short circuit on U, V, W lines.
ov A.400 DC Bus Overvoltage DC link voltage exceeded upper trip threshold; rapid deceleration without braking resistor, high incoming line voltage, or heavy inertial overhauling.
Uv1 A.410 DC Bus Undervoltage Intermediate DC bus dropped below minimum trip point; power loss, utility phase voltage sag, or damaged soft-charge relay/contactor.
oH / oH1 A.020 Heatsink Overheat Internal heatsink temperature exceeded allowable threshold; obstructed ventilation louvers, defective cooling fan, or high enclosure ambient (>50°C).
oL1 A.710 Motor Overload Motor electronic thermal overload calculated via I²t curve; sustained operation exceeding motor nameplate Full Load Amps (FLA).
oL2 A.720 Drive Overload Continuous current exceeded inverter maximum rated capacity; incorrect carrier frequency or undersized drive for continuous load.
GF A.040 Ground Fault Ground leakage current detected at drive output; motor cable moisture, damaged cable tray insulation, or stator ground puncture.
PF A.420 Input Phase Loss Excessive DC bus ripple detected due to open phase on incoming AC power lines (R/L1, S/L2, T/L3) or blown line supply fuse.

How to Clear & Reset Yaskawa Faults

  1. Digital Operator Reset: Press the red RESET key directly on the front LED or LCD digital operator keypad once the root cause has been addressed.
  2. Multi-Function Digital Input: Send a 24VDC pulse to the multi-function input terminal configured for fault reset (Parameter H1-01 to H1-08 set to function 14: Fault Reset).
  3. DriveWizard / SigmaWin+ Software: Connect via USB or serial port to DriveWizard Plus / Industrial or SigmaWin+ and click the “Fault Reset” button on the status monitor toolbar.
  4. Power Disconnect Cycle: Turn off main incoming AC power, wait until the internal red CHARGE LED completely turns off (minimum 5 minutes), and reapply utility power.
⚠️ High-Voltage Safety Warning: Intermediate DC bus capacitors remain charged at lethal voltage even after main input power is removed. Wait at least 5 minutes after all indicators turn off and verify with a calibrated digital multimeter that the DC voltage across terminals (+1, +2) and (-) is below 50VDC before inspecting electrical connections.