Yaskawa Drives Fault Codes & Troubleshooting
Complete diagnostic database for 20 Yaskawa drive series. Browse fault codes, alarms, causes, and step-by-step fixes for industrial AC variable speed inverters and high-performance servo motion amplifiers. Select your drive model series below to access parameter checks, root cause analysis, and physical inspection workflows.
Yaskawa AC Variable Frequency Drives
17 ModelsHigh-Performance Industrial Drive with Advanced Motor Control & Embedded Functional Safety
Premium Full-Featured Vector Control Inverter for Heavy Duty Synchronous & PM Motors
Low-Harmonic Matrix Converter Drive with Direct AC-to-AC Power Regeneration Architecture
Heavy Industrial 3-Level Inverter Platform Eliminating Motor Insulation & Bearing Stress
Compact Flexible Industrial Drive for Basic Machine Automation & Integrated Safe Torque Off
Flagship Compact Current Vector Micro Drive for Open-Loop Speed Regulation
Active Regenerative Front-End Converter for Common DC Bus Energy Recovery Systems
Dedicated HVAC & Building Automation Inverter Designed for Variable Torque Fans and Pumps
Industrial Fan and Pump Controller with Integrated Bypass and Multiplex Pumping Modes
Dedicated Variable Speed HVAC Drive Featuring BACnet/IP, DriveWizard Mobile & IP55 Options
Compact Micro Intelligent Pump Controller for Agriculture, Booster & Submersible Pumps
Intelligent Multiplex Pump Drive with Integrated Dry-Well, Pipe Fill & Flow Meter Logic
Dedicated Elevator Vector Inverter for Geared & Gearless Traction Machine Control
Custom Industrial Pump Drive Platform for Municipal Water, Wastewater & Slurry Sludge
Regenerative Braking Unit Replacing Dynamic Braking Resistors to Recycle Braking Power
Ultra-Clean Low-Harmonic Matrix Pumping Controller Operating at Near Unity Power Factor
Commercial Building HVAC Drive Engineered for Air Handling Units, Chillers & Cooling Towers
Yaskawa AC Servo Drives & Motion Systems
3 ModelsHigh-End AC Servo System with 3.1 kHz Frequency Response & 24-Bit Optical Encoders
Classic Standard Digital Servo Drive Series for Multi-Axis Robotics and Factory Automation
Advanced Motion Servo Amplifier Series with MECHATROLINK & Auto-Tuning Architecture
Most Common Yaskawa Drive Fault Codes
Diagnostic Quick Reference| Fault Code | Servo Alarm | Fault Name | Common Root Cause |
|---|---|---|---|
| oC | A.100 | Overcurrent | Drive output current exceeded peak rating; rapid acceleration ramp, mechanical load lockup, or short circuit on U, V, W lines. |
| ov | A.400 | DC Bus Overvoltage | DC link voltage exceeded upper trip threshold; rapid deceleration without braking resistor, high incoming line voltage, or heavy inertial overhauling. |
| Uv1 | A.410 | DC Bus Undervoltage | Intermediate DC bus dropped below minimum trip point; power loss, utility phase voltage sag, or damaged soft-charge relay/contactor. |
| oH / oH1 | A.020 | Heatsink Overheat | Internal heatsink temperature exceeded allowable threshold; obstructed ventilation louvers, defective cooling fan, or high enclosure ambient (>50°C). |
| oL1 | A.710 | Motor Overload | Motor electronic thermal overload calculated via I²t curve; sustained operation exceeding motor nameplate Full Load Amps (FLA). |
| oL2 | A.720 | Drive Overload | Continuous current exceeded inverter maximum rated capacity; incorrect carrier frequency or undersized drive for continuous load. |
| GF | A.040 | Ground Fault | Ground leakage current detected at drive output; motor cable moisture, damaged cable tray insulation, or stator ground puncture. |
| PF | A.420 | Input Phase Loss | Excessive DC bus ripple detected due to open phase on incoming AC power lines (R/L1, S/L2, T/L3) or blown line supply fuse. |
How to Clear & Reset Yaskawa Faults
- Digital Operator Reset: Press the red RESET key directly on the front LED or LCD digital operator keypad once the root cause has been addressed.
- Multi-Function Digital Input: Send a 24VDC pulse to the multi-function input terminal configured for fault reset (Parameter H1-01 to H1-08 set to function
14: Fault Reset). - DriveWizard / SigmaWin+ Software: Connect via USB or serial port to DriveWizard Plus / Industrial or SigmaWin+ and click the “Fault Reset” button on the status monitor toolbar.
- Power Disconnect Cycle: Turn off main incoming AC power, wait until the internal red CHARGE LED completely turns off (minimum 5 minutes), and reapply utility power.