Schneider Electric Drives Fault Codes & Troubleshooting
Technical diagnostic reference for Schneider Electric Altivar (ATV) process drives, machine inverters, compact building drives, and Lexium high-precision servo systems. Select your drive model series below to access parameter checks, trip code descriptions, and physical test sequences.
Schneider Altivar (ATV) Variable Speed Drives
20 ModelsMachine Inverter with Embedded Safety (STO, SS1, SLS, SMS, GDL) & Book/Compact Form
Process Drive with Embedded Web Server & Asset Monitoring for Pumps and Fans (0.75 to 315 kW)
Heavy Process Drive for Severe Industrial Applications, Hoisting, Cranes & Dynamic Loads
Compact Micro Drive for Small Commercial Machines and Conveyors (0.18 to 4 kW)
Easy Altivar General Purpose Inverter with High Robustness for Harsh Environments
High-Performance Machine Drive Engineered for Fast Dynamic Response & Heavy Torque
Easy Altivar Dedicated Inverter for Heavy Industrial Fan, Pump & Blower Operations
Dedicated HVAC Inverter for Building Automation, Damper Control & Smoke Extraction
IP55 / NEMA 12 Protected Wall-Mounted Variable Speed Process Drive for Harsh Sites
IP55 High-Protection Process Drive for Heavy Outdoor and Dusty Mining Installations
Services-Oriented Process Drive Platform with Embedded Power & Energy Monitoring
Services-Oriented Industrial Platform Engineered for Maximum Dynamic Shaft Efficiency
Solar-Powered Agricultural & Water Pumping Micro Drive with Auto-MPPT Algorithm
Classic Robust Machine Inverter with Integrated Modbus & CANopen Interfaces
Classic Photovoltaic Hybrid Pumping Inverter with Grid Backup Switching
Classic High-Torque Heavy Industrial Inverter for Hoisting, Winches & Extruders
Classic Industrial Fan and Pump Controller with Multi-Pump Staging Cards
Ultra-Slim Book-Format Machine Drive with Embedded ATV Logic (Programmable PLC)
Legacy General Purpose Industrial Frequency Inverter for 3-Phase Induction Motors
Standard Compact Machine Inverter with Coated Electronic Printed Circuit Boards
Schneider Lexium AC Servo Systems
7 ModelsFlagship Modular Motion Servo Drive with EtherCAT, CANopen & PROFINET Bus Interfaces
High-Performance Optimized Servo Drive with Embedded CANopen for Multi-Axis Machines
Cost-Optimized Standalone Servo System for Standard Packaging, Handling & Labeling
Standard Dynamic Servo Drive with Open Collector Pulse-Train & Analog Velocity Inputs
Classic Compact AC Servo Amplifier for BSH High-Dynamic Brushless Servo Motors
Classic Multi-Axis Digital Servo Controller for High-Inertia Precision Actuators
Digital Stepper and Servo Hybrid Drive for Low-Power Compact Positioning Axis
Most Common Schneider Altivar Fault Codes
Diagnostic Quick Reference| Trip Code | Trip Name | Common Physical Trigger | Recommended First Check |
|---|---|---|---|
| OCF | Overcurrent Fault | Output current exceeded safe electronic threshold due to rapid accel, mechanical jam, or short circuit. | Extend acceleration ramp time (ACC) and check motor terminal box for phase-to-phase shorts. |
| OSF | Mains Overvoltage | Line voltage too high or motor regenerative energy during braking pushing DC bus voltage over limit. | Verify incoming line voltage across L1, L2, L3 and extend deceleration ramp (DEC) or add dynamic braking. |
| USF | Mains Undervoltage | Supply voltage dropped below operating trip threshold (line sag, blown fuse, or power outage). | Measure mains input voltage and verify that the main line supply contactor is not chattering. |
| OHF | Drive Overheating | Internal thermal sensor measuring heatsink temperature higher than permissible operating limit. | Check cooling fan rotation, clear cabinet air vents, and blow accumulated lint/dust from heatsink fins. |
| OLF | Motor Overload | Motor thermal state exceeding 118% of rated current based on internal calculated thermal curve. | Verify motor rated current setting (ItH) matches physical motor nameplate FLA; check mechanical load. |
| SCF1 / SCF3 | Motor Short Circuit / Ground Fault | Output phase short-circuit or high ground leakage current detected at motor terminals (U, V, W). | Disconnect motor leads from drive; if drive still trips on OCF/SCF without motor, IGBT bridge is shorted. |
| OPF1 / OPF2 | Output Phase Loss | One or all three motor phase output lines disconnected or motor drawing zero current on one phase. | Inspect output contactors, motor disconnect switches, and terminal screw torques on U, V, and W. |
| PHF | Mains Phase Loss | Supply line missing one phase or line voltage unbalance exceeding allowable limit. | Check line supply fuses and upstream circuit breakers for single-phasing conditions. |
How to Clear & Reset Schneider Altivar Faults
- Keypad Reset: Press the red STOP/RESET button directly on the front operator display or the Graphic Display Terminal.
- Digital Input Reset (rSt): Pulse the digital input terminal assigned to the “Fault Reset” function (configured in menu [FAULT MANAGEMENT] $\rightarrow$ [FAULT RESET] (rSt), typically assigned to LI1–LI6).
- SoMove Commissioning Software: Connect via Modbus serial/USB cable or Ethernet, open the diagnostic dashboard, and click “Fault Clear”.
- Communication Control Word: Write bit 7 (Fault Acknowledge) from `0` to `1` in the CANopen, Modbus/TCP, or Ethernet/IP drive command word (CMD).
- Power Cycle: Disconnect the incoming 3-phase mains supply, wait until the display screen and internal green charging LED turn off completely, and reapply power.