Schneider

Home / Schneider

Schneider Electric Drives Fault Codes & Troubleshooting

Technical diagnostic reference for Schneider Electric Altivar (ATV) process drives, machine inverters, compact building drives, and Lexium high-precision servo systems. Select your drive model series below to access parameter checks, trip code descriptions, and physical test sequences.

20 Altivar Drive Series 7 Lexium Servo Systems Services & Process Ready

Schneider Altivar (ATV) Variable Speed Drives

20 Models
ATV320 →

Machine Inverter with Embedded Safety (STO, SS1, SLS, SMS, GDL) & Book/Compact Form

ATV630 →

Process Drive with Embedded Web Server & Asset Monitoring for Pumps and Fans (0.75 to 315 kW)

ATV930 →

Heavy Process Drive for Severe Industrial Applications, Hoisting, Cranes & Dynamic Loads

ATV12 →

Compact Micro Drive for Small Commercial Machines and Conveyors (0.18 to 4 kW)

ATV310 →

Easy Altivar General Purpose Inverter with High Robustness for Harsh Environments

ATV340 →

High-Performance Machine Drive Engineered for Fast Dynamic Response & Heavy Torque

ATV610 →

Easy Altivar Dedicated Inverter for Heavy Industrial Fan, Pump & Blower Operations

ATV212 →

Dedicated HVAC Inverter for Building Automation, Damper Control & Smoke Extraction

ATV650 →

IP55 / NEMA 12 Protected Wall-Mounted Variable Speed Process Drive for Harsh Sites

ATV950 →

IP55 High-Protection Process Drive for Heavy Outdoor and Dusty Mining Installations

ATV600 →

Services-Oriented Process Drive Platform with Embedded Power & Energy Monitoring

ATV900 →

Services-Oriented Industrial Platform Engineered for Maximum Dynamic Shaft Efficiency

ATV320 Solar →

Solar-Powered Agricultural & Water Pumping Micro Drive with Auto-MPPT Algorithm

ATV312 →

Classic Robust Machine Inverter with Integrated Modbus & CANopen Interfaces

ATV312 Solar →

Classic Photovoltaic Hybrid Pumping Inverter with Grid Backup Switching

ATV71 →

Classic High-Torque Heavy Industrial Inverter for Hoisting, Winches & Extruders

ATV61 →

Classic Industrial Fan and Pump Controller with Multi-Pump Staging Cards

ATV32 →

Ultra-Slim Book-Format Machine Drive with Embedded ATV Logic (Programmable PLC)

ATV31 →

Legacy General Purpose Industrial Frequency Inverter for 3-Phase Induction Motors

ATV303 →

Standard Compact Machine Inverter with Coated Electronic Printed Circuit Boards

Schneider Lexium AC Servo Systems

7 Models

Most Common Schneider Altivar Fault Codes

Diagnostic Quick Reference
Trip Code Trip Name Common Physical Trigger Recommended First Check
OCF Overcurrent Fault Output current exceeded safe electronic threshold due to rapid accel, mechanical jam, or short circuit. Extend acceleration ramp time (ACC) and check motor terminal box for phase-to-phase shorts.
OSF Mains Overvoltage Line voltage too high or motor regenerative energy during braking pushing DC bus voltage over limit. Verify incoming line voltage across L1, L2, L3 and extend deceleration ramp (DEC) or add dynamic braking.
USF Mains Undervoltage Supply voltage dropped below operating trip threshold (line sag, blown fuse, or power outage). Measure mains input voltage and verify that the main line supply contactor is not chattering.
OHF Drive Overheating Internal thermal sensor measuring heatsink temperature higher than permissible operating limit. Check cooling fan rotation, clear cabinet air vents, and blow accumulated lint/dust from heatsink fins.
OLF Motor Overload Motor thermal state exceeding 118% of rated current based on internal calculated thermal curve. Verify motor rated current setting (ItH) matches physical motor nameplate FLA; check mechanical load.
SCF1 / SCF3 Motor Short Circuit / Ground Fault Output phase short-circuit or high ground leakage current detected at motor terminals (U, V, W). Disconnect motor leads from drive; if drive still trips on OCF/SCF without motor, IGBT bridge is shorted.
OPF1 / OPF2 Output Phase Loss One or all three motor phase output lines disconnected or motor drawing zero current on one phase. Inspect output contactors, motor disconnect switches, and terminal screw torques on U, V, and W.
PHF Mains Phase Loss Supply line missing one phase or line voltage unbalance exceeding allowable limit. Check line supply fuses and upstream circuit breakers for single-phasing conditions.

How to Clear & Reset Schneider Altivar Faults

  1. Keypad Reset: Press the red STOP/RESET button directly on the front operator display or the Graphic Display Terminal.
  2. Digital Input Reset (rSt): Pulse the digital input terminal assigned to the “Fault Reset” function (configured in menu [FAULT MANAGEMENT] $\rightarrow$ [FAULT RESET] (rSt), typically assigned to LI1–LI6).
  3. SoMove Commissioning Software: Connect via Modbus serial/USB cable or Ethernet, open the diagnostic dashboard, and click “Fault Clear”.
  4. Communication Control Word: Write bit 7 (Fault Acknowledge) from `0` to `1` in the CANopen, Modbus/TCP, or Ethernet/IP drive command word (CMD).
  5. Power Cycle: Disconnect the incoming 3-phase mains supply, wait until the display screen and internal green charging LED turn off completely, and reapply power.
⚠️ High-Voltage Safety Warning: Always verify with a calibrated digital multimeter that intermediate DC bus capacitor voltage measures strictly below 50VDC across terminals [PA/+] and [PC/-] before opening terminal covers or servicing output terminals U, V, and W on any Schneider Altivar drive.