Schneider ATV310 Drive Fault Codes & Diagnostic Guide
Complete fault code reference directory, trip alarm causes, and step-by-step troubleshooting procedures for the Schneider Electric Easy Altivar ATV310 compact inverter series. Search or filter through the complete fault code directory below.
Power Range
0.37 – 11 kW (0.5 – 15 HP)
Supply Voltage
380–460V AC (3-Phase)
Control Modes
Sensorless Vector (SVC) & V/f
Operator Interface
Built-in 4-Digit Display & Dial
Complete Schneider ATV310 Drive Fault Code Directory
Use the search box in the table below to quickly find your code (e.g., type F010, F011, F018, or Overcurrent).
| Fault Code and Meaning | Cause and Remedy |
|---|---|
| ---- Problem with application firmware | Cause: Invalid application firmware update using the Multi-Loader tool. Remedy:
|
| F001 Precharge | Cause: Charging relay control fault or charging resistor damaged. Remedy:
|
| F002 Unknown drive rating | Cause: Power card and stored card versions different. Remedy:
|
| F003 Unknown or incompatible power board | Cause: The power card is incompatible with the control card. Remedy:
|
| F004 Internal serial link fault | Cause: Communication interruption between the internal cards. Remedy:
|
| F005 Invalid industrialization zone | Cause: Internal data inconsistent. Remedy:
|
| F006 Current measurement circuit | Cause: Current measurement is not correct due to hardware circuit fault. Remedy:
|
| F007 Internal thermal sensor detected fault | Cause:
Remedy:
|
| F008 Internal CPU | Cause: Internal microprocessor fault. Remedy:
|
| F010 Overcurrent | Cause:
Remedy:
|
| F018 Motor short-circuit | Cause:
Remedy:
|
| F019 Ground short-circuit | Cause:
Remedy:
|
| F020 IGBT short circuit | Cause: Internal power component short circuit detected at power on. Remedy:
|
| F025 Overspeed | Cause:
Remedy:
|
| F028 Autotuning fault | Cause:
Remedy:
|
| F036 Angle setting fault | Cause: This occurs during the phase-shift angle measurement, if the motor phase is disconnected or if the motor inductance is too high. Remedy:
|
| F009 Overbraking | Cause: Sudden braking or load inertia too high. Remedy:
|
| F011 Drive overheat | Cause: Drive temperature too high. Remedy:
|
| F012 Process overload fault | Cause: Process overload. Remedy:
|
| F013 Motor overload | Cause: Triggered by excessive motor current. Remedy:
|
| F014 1 Output phase loss | Cause: Loss of one phase on drive output. Remedy:
|
| F015 3 Output phases loss | Cause:
Remedy:
|
| F016 Main overvoltage | Cause:
Remedy:
|
| F017 Input phase loss | Cause:
Remedy:
|
| F021 Load short circuit | Cause:
Remedy:
|
| F022 Modbus interruption | Cause: Interrupted communication on the Modbus network. Remedy:
|
| F024 HMI communication | Cause: Communication interruption with the external display terminal. Remedy:
|
| F026 PI feedback fault | Cause: PID feedback below lower limit. Remedy:
|
| F027 IGBT overheat | Cause:
Remedy:
|
| F029 Process underload fault | Cause:
Remedy:
|
| F033 AI1 current loss | Cause:
Remedy:
|
| F030 Undervoltage | Cause:
Remedy:
|
| F031 Incorrect configuration | Cause:
Remedy:
|
| F032 Invalid configuration | Cause:
Remedy:
|
| F034 Download invalid configuration | Cause: When save parameter setting or restore to factory setting, the drive detects invalid configuration. Remedy:
|
InIt: Auto-initialization on start | Cause:
Remedy: |
COM.E (Flashing) Communication error | Cause:
Remedy: |
A-17 (Flashing) Key alarm | Cause:
Remedy: |
cLr (Flashing) Confirm fault reset | Cause: This message appears if the STOP key is pressed while the display terminal is displaying a fault. Remedy: |
dEU.E (Flashing) Drive mismatch | Cause: Drive type (brand) does not match display terminal type (brand). Remedy: |
rOM.E (Flashing) ROM abnormality | Cause: ROM abnormality detected by checksum calculation. Remedy: |
rAM.E (Flashing) RAM abnormality | Cause: Display terminal RAM abnormality detected. Remedy: |
CPU.E (Flashing) Other fault | Cause: The other detected fault. Remedy: |
How to Clear & Reset Schneider ATV310 Drive Faults
- Keypad Reset: Press the red STOP/RESET key on the front control panel. Ensure the cause of the fault has been removed before initiating a reset.
- Logic Input Reset (LI): If configured in parameter 601 (Fault reset assignment) in the [FAULT MANAGEMENT] (600-) menu, toggle the assigned digital input (e.g., LI1 to LI4) with a +24V transition.
- Automatic Restart: For non-critical trip conditions (e.g., supply undervoltage or transient overvoltage), enable parameter 602.0 (Automatic restart) to automatically reset the drive once line voltage stabilizes.
- Modbus Serial Network: Pulse Bit 7 (Fault Reset) from 0 to 1 in the drive Control Word (CMD / register 8501) via embedded RJ45 Modbus RTU communication.
- Power Cycle: Disconnect the incoming AC power supply, wait at least 15 minutes for internal capacitors to discharge until the 4-digit LED display goes completely dark, then reapply power.
⚠️ High-Voltage Electrical Safety Warning:
Always verify with a calibrated digital multimeter that the DC bus voltage measures strictly below 42VDC across terminals [PA/+] and [PB] (or internal DC bus test points) before opening terminal covers or servicing output terminals U, V, and W on the Schneider Easy Altivar ATV310 drive.