Inovance Drives Fault Codes & Troubleshooting
Complete diagnostic database for 20 Inovance drive series. Browse fault codes, alarms, causes, and step-by-step fixes for AC & servo drives. Select your drive model series below to access parameter checks, root cause analysis, and physical inspection workflows.
Inovance AC Variable Frequency Drives
12 ModelsCompact Multi-Drive System Designed for Multi-Axis Booksize Cabinet Integration
Compact Open-Loop V/f Micro Inverter for Small Power Machine Automation
High-Performance Open & Closed-Loop Vector Drive for Asynchronous & PM Motors
Flagship Heavy-Duty Industrial Vector Drive with Advanced Motor Auto-Tuning
Economical General-Purpose Vector Control Inverter for Demanding Plant Machinery
Enhanced Dynamic Vector Drive Featuring Dual-Rating and High Starting Torque
Standard Compact Open-Loop Vector Drive for Conveyors, Mixers & Machine Tools
Specialized High-Response Servo Inverter for Hydraulic Injection Molding Systems
Universal Standard Variable Frequency Drive for Constant and Variable Torque Loads
Dedicated Crane and Hoist Frequency Inverter with Integrated Brake Logic Control
Dedicated Fan and Water Pump Application Inverter with Multi-Pump Sleep Control
Heavy Industrial Common DC Bus Modular Multi-Drive System for Continuous Processing
Inovance AC Servo Drives & Motion Systems
8 ModelsEtherCAT Real-Time Bus Servo Drive with Integrated STO (SIL3) Safety Architecture
Compact Pulse Train and Analog Direction Control High-Speed AC Servo Drive
PROFINET Real-Time Communication Servo Drive with PROFIdrive Support
High-Performance Pulse Servo Drive with 23-Bit Encoder and Dynamic Load Adaptation
Multi-Axis Servo System with Common DC Bus Design for Heavy Machine Automation
Compact Dual-Axis Servo Drive with Shared DC Power Stage for Compact Panels
High-End EtherCAT Communication AC Servo Drive for Precision Robotics and CNC
Standard Industrial Pulse / Direction Servo Drive for Electronic Assembly Lines
Most Common Inovance Drive Fault Codes
Diagnostic Quick Reference| Inovance Fault Code | Servo Code | Fault Name | Common Root Cause |
|---|---|---|---|
| Err02 / Err03 | Er.102 | Overcurrent (Accel / Decel) | Acceleration or deceleration ramp too fast, mechanical jam, or short circuit across motor phases U, V, and W. |
| Err05 / Err06 | Er.120 | Overvoltage (Accel / Decel) | Excess regenerative energy during deceleration; check braking resistor connection or lengthen deceleration ramp. |
| Err09 | Er.130 | Undervoltage | DC link voltage dropped below trip limit; supply grid sag, blown line fuse, or faulty main circuit contactor. |
| Err10 / Err11 | Er.400 | Drive / Motor Overload | Continuous operation exceeding rated current; mechanical binding or improper motor parameter configuration in Group F1. |
| Err14 | Er.420 | Module Overheat (IGBT) | Air duct clogged, cooling fan malfunction, high ambient temperature (>50°C), or loose heatsink mounting screws. |
| Err23 | Er.104 | Output Ground Fault | Leakage current detected from motor phases to earth; inspect cable insulation breakdown or damp motor terminal box. |
| Err12 | Er.131 | Input Phase Loss | Missing phase on incoming power lines R, S, T; loose supply terminals or blown upstream circuit breaker. |
How to Clear & Reset Inovance Faults
- Keypad Reset: Press the red STOP/RESET key on the physical operating keypad once the fault cause has been removed.
- Digital Input (DI) Terminal: Send an external pulse to the digital input configured for fault reset (set multi-function terminal parameter F4-00 to F4-04 to function
9: Fault reset (RESET)). - Software / Fieldbus Reset: Reset via Inovance commissioning software (InoDriverShop or InoShop) by clicking “Fault Reset”, or write the reset bit via Modbus/EtherCAT communication control word.
- Mains Power Cycle: Turn off main input AC power, wait 5 minutes until the charge indicator LED turns completely off, and restore power.