Inovance SV820 Multi-Axis Servo Drive Fault Codes & Diagnostic Guide
Complete fault code reference directory, multi-axis alarm causes, and step-by-step troubleshooting procedures for the Inovance SV820 multi-axes AC servo system. Search or filter through the complete error code directory below.
Power Range
0.1 – 3.0 kW (100W – 750W/Axis)
Supply Voltage
1PH / 3PH 200–240V AC
Control Networks
EtherCAT (CiA 402) & CANopen
Operator Interface
LED Display / InoDriveStudio
Complete Inovance SV820 Servo Drive Fault Code Directory
Use the search box in the table below to quickly find your code (e.g., type Er.101, Er.201, or Overcurrent).
| Fault Code and Meaning | Cause and Remedy |
|---|---|
| E3.101 System parameter error | Cause: The total number of parameters changes or values exceed limits (often after software update). Specific causes include: 1. Control power voltage drops instantaneously. 2. Instantaneous power failure during parameter storage. 3. Excessive write operations by host controller. 4. Software was updated. 5. The servo drive is faulty. Remedy:
|
| E3.102 Abnormal communication initialization of coprocessor | Cause: Multi-core communication initialization fault or CPU core software version mismatch. 1. Software version of FPGA and CPU cores do not match. 2. The FPGA is faulty. Remedy:
|
| E3.104 Abnormal communication or interrupt timeout of coprocessor | Cause: Interrupt timeout on coprocessor/FPGA or cyclic access timeout. 1. The FPGA is faulty. 2. Abnormal communication handshake between FPGA and MCU. 3. Interrupt timeout on the MCU. Remedy:
|
| E3.105 Internal program error | Cause: Abnormal parameter count during EEPROM read/write or abnormal value range. 1. An EEPROM fault occurs. 2. The servo drive is faulty. Remedy:
|
| E3.106 Abnormal communication handshake of main processor | Cause: Internal communication handshake issue. To distinguish specific causes, view internal fault codes in 200B-2Eh. Remedy:
|
| E3.107 Main processor communication loss | Cause: Cyclic handshake communication loss between main processor and coprocessor. 1. Internal communication failure. Remedy:
|
| E3.108 Parameter storage fault | Cause: Parameter values cannot be written to or read from EEPROM. 1. Write operation is abnormal. 2. Read operation is abnormal. Remedy:
|
| E3.111 Abnormal parameters in group 2000h/2001h | Cause: Parameter changes or limits exceeded in group 2000/2001. 1. Instantaneous power failure during parameter storage. 2. Power failure during writing serial encoder motor parameters. 3. Software is updated. 4. Servo drive is faulty. Remedy:
|
| E3.120 Mismatch of the product model | Cause: Motor/Drive model mismatch, improper parameters, or wrong auto-tuned drive model. 1. Product (encoder, motor, drive) code does not exist (Internal code 1120 or 2120). 2. Power ratings do not match (Internal code 3120). 3. Drive unit model set improperly (mismatch with auto-tuned result). 4. FPGA software does not support motor code. Remedy:
|
| E3.121 Invalid S-ON command | Cause: A redundant S-ON signal is sent when auxiliary functions are used. 1. S-ON switched on through communication while drive is enabled internally. Remedy:
|
| E3.122 Motor mismatch in absolute position mode | Cause: 1. The motor does not match in absolute position mode. 2. The motor code is set incorrectly. Remedy:
|
| E3.130 DI function setting error | Cause:
Remedy:
|
| E3.131 DO function setting error | Cause: The DO function setting is wrong. Check set values of 2004-01h (DO1 logic) and 2004-03h (DO2 logic). Remedy:
|
| E3.136 Data check error or no parameter stored in motor encoder ROM | Cause:
Remedy:
|
| E3.150 STO input protection | Cause: The STO (Safe Torque Off) input protection applies. Remedy:
|
| E3.201 Overcurrent | Cause: Hardware overcurrent detected.
Remedy:
|
| E3.202 Soft start relay disconnected | Cause: The soft start relay is disconnected. Remedy:
|
| E3.206 Switching frequency error | Cause: The motor control is abnormal. Remedy:
|
| E3.208 FPGA sampling operation timeout | Cause: Internal fault code (200B-2Eh).
Remedy:
|
| E3.210 Output shorted to ground | Cause: The servo drive detects abnormal motor phase current or bus voltage during self-check upon power-on. Root causes include shorted power cables, shorted motor, or a faulty drive. Remedy:
|
| E3.220 Wrong UVW phase sequence | Cause: Incorrect UVW phase sequence is detected during angle auto-tuning. Remedy:
|
| E3.234 Runaway | Cause: The torque reference direction is in reverse to the speed feedback. Issues may include incorrect phase sequence, interference signals, wrong encoder model/wiring, or loose connections. Remedy:
|
| E3.400 Main circuit overvoltage | Cause: DC bus voltage exceeds threshold (420V for 220V drive). Caused by high input voltage, unstable power supply, regenerative resistor failure, insufficient braking energy absorption, or abrupt deceleration. Remedy:
|
| E3.410 Main circuit undervoltage | Cause: DC bus voltage is lower than threshold (200V). Caused by unstable power, instantaneous power failure, voltage drops during running, or phase loss. Remedy:
|
| E3.420 Main circuit phase loss | Cause: Phase loss on three-phase drive. Caused by loose cables, single-phase supply used on 3-phase drive, or imbalanced supply. Remedy:
|
| E3.430 Control power undervoltage | Cause: Phase loss occurs on the AC input of the control circuit, or input is unstable. Remedy:
|
| E3.500 Motor overspeed | Cause: Actual speed exceeds threshold. Caused by incorrect phase sequence, improper threshold setting (200A-09h), input reference exceeding limits, or speed overshoot. Remedy:
|
| E3.602 Angle auto-tuning failure | Cause: Abnormal jitter occurs on the encoder feedback during angle auto-tuning, or encoder feedback data error occurs. Remedy:
|
| E3.610 Servo drive overload | Cause: The servo motor temperature reaches the over-temperature threshold. Remedy:
|
| E3.620 Motor overload | Cause: The servo motor temperature reaches the over-temperature threshold. Root causes include improper wiring, heavy load, frequent accel/decel, improper gain, incorrect model setting, or mechanical locked-rotor. Remedy:
|
| E3.630 Locked-rotor over-temperature protection | Cause: The actual motor speed is lower than 10 RPM but the torque reference reaches the limit and lasts for the defined time. Caused by phase loss, disconnected cables, or mechanical locked-rotor. Remedy:
|
| E3.650 Heatsink over-temperature | Cause: The temperature of the power module is higher than the over-temperature protection threshold. Remedy:
|
| E3.731 Encoder battery failure | Cause: The battery voltage of the absolute encoder is lower than 3.0 V, or battery was not connected during power-off. Remedy:
|
| E3.733 Encoder multi-turn counting error | Cause: The encoder multi-turn counting value is wrong (Encoder faulty). Remedy:
|
| E3.735 Encoder multi-turn counting overflow | Cause: The number of unidirectional revolutions of the absolute encoder exceeds 32767 in linear mode. Remedy:
|
| E3.740 Encoder interference | Cause: Encoder communication suffers from interference (wiring, vibration, Z signal interference, or faulty encoder). Remedy:
|
| E3.A33 Encoder data read/write error | Cause: Internal parameters of the encoder are abnormal. Remedy:
|
| E3.B00 Excessive position deviation | Cause: The position deviation is larger than the value of 6065h in position control mode. Remedy:
|
| E3.B01 Position reference incremental error | Cause: The target position increment in CSP mode is too large, or alignment issues during mode switchover. Remedy:
|
| E3.B03 Electronic gear ratio over the limit | Cause: The electronic gear ratio exceeds the limit. Remedy:
|
| E3.D09 Software position setting error | Cause: The lower limit of the software position is set to a value larger than the upper limit (Value of 607D-01 > 607D-02). Remedy:
|
| E3.D10 Home setting error | Cause: The home offset is beyond the software limit. The value of 607Ch (Home offset) is beyond the values of 607D-01 (Min. position limit) and 607D-02 (Max. position limit). Remedy:
|
| E3.601 Homing warning | Cause: The home is not found within the time defined, or the home/limit switch is abnormal. Remedy:
|
| E3.730 Encoder battery warning | Cause: The battery voltage of the absolute encoder is lower than 3.0 V. Remedy:
|
| E3.908 Abnormal drive unit model | Cause: The model of the drive unit detected is abnormal, contacts are poor, or EEPROM data is incorrect. Remedy:
|
| E3.909 Motor overload | Cause: Motor temperature (60Z series) reached over-temperature threshold. Causes include poor cabling, excessive load, frequent accel/decel, or improper gain. Remedy:
|
| E3.920 Regenerative resistor overload | Cause: Regenerative resistor temperature exceeds set value. Issues with cabling, settings (H02-25, H02-27), or input voltage. Remedy:
|
| E3.922 Resistance of external regenerative resistor too small | Cause: The value of H02-27 is smaller than the permissible minimum (H02-21). Remedy:
|
| E3.939 Motor power cable disconnected | Cause: Phase current < 10% of rated current, small speed but large internal torque reference. Remedy:
|
| E3.941 Parameter modifications activated at next power-on | Cause: Parameters with "Effective time: Next power-on" were modified. Remedy:
|
| E3.942 Parameter storage too frequent | Cause: Total number of parameters modified at a time exceeds 200, or frequent EEPROM writes. Remedy:
|
| E3.950 Forward overtravel | Cause: DI function 14 (P-OT) valid or position feedback exceeds positive software limit (607D-02). Remedy:
|
| E3.952 Reverse overtravel | Cause: DI function 15 (N-OT) valid or position feedback exceeds negative software limit (607D-01). Remedy:
|
| E3.980 Encoder fault | Cause: An internal encoder algorithm error occurred. Remedy:
|
| E3.990 Power input phase loss warning | Cause: A 3-phase drive is running on single-phase power while H0A-00 is set to 1. Remedy:
|
| E3.998 Homing object dictionary setting error | Cause: The homing mode (6098h) is set to a value not supported. Remedy:
|
| E3.E20 Ethernet hardware error | Cause: An Ethernet hardware fault occurred. Remedy:
|
| E3.E21 MAC address not programmed | Cause: The MAC address of the servo drive is not programmed. Remedy:
|
| E3.E08 Abnormal switchover of network status | Cause: Synchronization signal abnormal. Issues with cable, grounding, master clock, or network switchover logic. Remedy:
|
| E3.E09 No synchronization signal | Cause: Clock not configured, improper master config, or reversed IN/OUT ports. Remedy:
|
| E3.E11 ESI configuration file not programmed | Cause: ESI file missing (Slave ID is null) or drive is faulty. Remedy:
|
| E3.E13 Synchronization cycle configuration error | Cause: Sync cycle is not an integer multiple of the command scheduling cycle. Remedy:
|
| E3.E15 Synchronization cycle error too large | Cause: The error of the controller synchronization cycle exceeds the threshold. Remedy:
|
How to Clear & Reset Inovance SV820 Multi-Axis Servo Drive Faults
- EtherCAT / Motion Controller Reset: Trigger an alarm reset command via the motion bus by transitioning Bit 7 of the CiA 402 Controlword (
0x6040) from 0 to 1 for the specific tripped axis. - Digital Input Reset (ALM-RST): Pulse the digital input terminal assigned to the Fault Reset function (ALM-RST) configured within the multi-axis I/O allocation group.
- InoDriveStudio PC Software: Connect via the USB or diagnostic communication port, launch InoDriveStudio, view the multi-axis status overview, and execute the “Fault Reset” function.
- Integrated Keypad Reset: Use the front navigation buttons on the central LED module to access auxiliary parameter menus and reset non-critical faults.
- Common DC Bus Power Cycle: Switch off the main incoming AC power supply to the central power unit. Wait 10 to 15 minutes for the shared DC bus capacitors to fully bleed down and for all status LEDs to turn completely off, then re-energize.
⚠️ Shared DC Bus & Multi-Axis Robotic Safety Warning:
The Inovance SV820 shares a high-voltage common DC link across all coordinated axes. Always verify with a calibrated digital multimeter that intermediate DC bus voltage across terminals P(+) and (-) has discharged completely below 36VDC before disconnecting any motor power leads (U, V, W), servicing absolute encoder connectors, or working near suspended mechanical robot arms.