Inovance IS810N Servo Drive Fault Codes & Diagnostic Guide
Complete fault code reference directory, trip alarm causes, and step-by-step troubleshooting procedures for the Inovance IS810N multi-axis EtherCAT servo drive platform. Search or filter through the complete fault code directory below.
Power Range
0.85 – 75 kW (Rectifier Up to 355 kW)
Supply Voltage
3-Ph 380–480V AC (DC Bus 537–679V DC)
Control Modes
CSP, CSV, CST, Profile & Homing (CiA 402)
Operator Interface
Built-in 5-Digit LED / InoDriverShop PC Tool
Complete Inovance IS810N Drive Fault Code Directory
Use the search box in the table below to quickly find your code (e.g., type E1.101, E12.01, or Overcurrent).
| Fault Code and Meaning | Cause and Remedy |
|---|---|
| E12.01 Input voltage abnormal | Cause: R phase loss occurs on input voltage. Remedy:
|
| E12.02 Input voltage abnormal | Cause: S phase loss occurs on input voltage. Remedy:
|
| E12.03 Input voltage abnormal | Cause: T phase loss occurs on input voltage. Remedy:
|
| E12.04 Input voltage abnormal | Cause: The input three-phase voltage is too high. Remedy:
|
| E12.05 Input voltage abnormal | Cause: Three-phase input voltage unbalance occurs. Remedy:
|
| E14.00 SCR overheat | Cause: - The ambient temperature is too high. - The ventilation is clogged. - The fan is damaged. - The thermally sensitive resistor of SCR is damaged. - The SCR is damaged. Remedy:
|
| E16.01 Communication fault | Cause: Modbus communication times out. Remedy:
|
| E16.11 Communication fault | Cause: CANopen communication times out. Remedy:
|
| E16.12 Communication fault | Cause: The PDO mapping configured for CANopen is not consistent with the actual mapping. Remedy:
|
| E16.13 Communication fault | Cause: Data exchange times out when the drive units receive data from the power supply unit. Remedy:
|
| E16.14 Communication fault | Cause: Data exchange is abnormal when the drive units receive data from the power supply unit. Remedy:
|
| E16.21 Communication fault | Cause: The CANlink heartbeat times out. Remedy:
|
| E16.22 Communication fault | Cause: CANlink station numbers conflict. Remedy:
|
| E16.31 Communication fault | Cause: Profibus-DP communication times out (specific to Profibus-DP-to-CANopen bridge mode). Remedy:
|
| E16.34 Communication fault | Cause: A CAN slave is offline during Profibus-DP-to-CANopen bridge configuration. Remedy:
|
| E16.35 Communication fault | Cause: Parameters of Profibus-DP-to-CANopen bridge configuration are incorrectly set. Remedy:
|
| E16.41 Communication fault | Cause: Profibus-DP communication times out. Remedy:
|
| E16.42 Communication fault | Cause: Parameters of Profibus-DP-to-CANopen bridge configuration are incorrectly set. Remedy:
|
| E16.71 Communication fault | Cause: PROFINET communication times out. Remedy:
|
| E16.72 Communication fault | Cause: The CANopen slave communication times out. Remedy:
|
| E16.74 Communication fault | Cause: The configured CANopen slave is missing. Remedy:
|
| E16.75 Communication fault | Cause: CANopen mapping data does not match. Remedy:
|
| E16.76 Communication fault | Cause: The process data of the power supply unit does not match the configuration. Remedy:
|
| E16.77 Communication fault | Cause: An internal serial communication fault occurs. Remedy:
|
| E16.78 Communication fault | Cause: An internal SPI communication fault occurs. Remedy:
|
| E61.01 Braking unit fault | Cause: The braking unit is directly connected. Remedy:
|
| E61.02 Braking unit fault | Cause: Overcurrent occurs on the braking unit. Remedy:
|
| E61.03 Braking unit fault | Cause: Overload occurs on the braking unit. Remedy:
|
| E61.04 Braking unit fault | Cause: An overheat warning is detected on the braking unit. Remedy:
|
| E61.05 Braking unit fault | Cause: The braking unit overheats. Remedy:
|
| -H-C- HC Displayed | Cause: - Related components on control board are damaged. - Motor or motor cable short circuited to ground. - The hall is damaged. - Mains voltage is too low. Remedy:
|
| E23.00 Motor short circuit | Cause: - The motor or motor cable is short circuited to the ground. - The power supply unit is damaged. Remedy:
|
How to Clear & Reset Inovance IS810N Drive Faults
- Keypad Parameter Reset: Turn off the servo enable (S-ON) signal for the tripped axis. Navigate to auxiliary parameter H0d.01 or object 200D-02h (Fault reset) and set its value to 1 using the module keypad.
- Digital Input Reset (DI): With the S-ON signal removed, apply an active pulse signal (held high for at least 3 ms) to the digital input terminal configured with function FunIN.2 (ALM-RST: Fault and Warning Reset).
- InoDriverShop Commissioning Tool: Connect your PC via the dedicated RJ45 Ethernet port (Modbus TCP) or serial comms interface, launch InoDriverShop, inspect active alarms and logs in parameter group H0B, and execute the “Fault Reset” command.
- EtherCAT CiA 402 Controlword: In your master PLC or motion controller, write a rising edge transition from 0 to 1 on Bit 7 (Fault Reset) within Controlword 0x6040 for the affected axis over EtherCAT.
- Power Cycle: Disconnect both the 3-phase AC mains supply to the central rectifier unit (MD810) and the 24V DC auxiliary control power. Wait at least 15 minutes until the shared DC busbar discharges completely and the CHARGE LED turns off before restoring power.
⚠️ High-Voltage Electrical Safety Warning:
The Inovance IS810N platform operates across a high-energy common DC bus linking the rectifier and multiple drive axes (537 to 679 VDC or higher). Always isolate upstream 3-phase AC power to the central power supply module and verify with a calibrated digital multimeter that the shared DC busbar voltage across [+] and [-] has dropped strictly below 36 VDC before disconnecting modules, servicing motor power terminals (U, V, W), or removing protective shrouds.