Nidec Control Techniques

Home / Nidec Control Techniques

Nidec Control Techniques Drives Fault Codes & Troubleshooting

Complete diagnostic database for 23 Nidec Control Techniques drive series. Browse fault codes, trip codes, causes, and step-by-step fixes for industrial AC variable speed drives and high-performance servo motion amplifiers. Select your drive model series below to access parameter checks, root cause analysis, and physical inspection workflows.

18 AC / Industrial Series 5 Servo Motion Drives 23 Total Series

Nidec Control Techniques AC & Industrial Drives

18 Models
Commander C200 & C300 →

Standard Industrial General Purpose Machinery Inverters with Dual STO Safety

Commander S →

Compact Micro Drive with Integrated NFC Interface & Marshal App Commissioning

Commander SE →

Classic Open-Loop Vector Control Component Micro Drive for General Machinery

Commander SK →

Proven Compact AC Variable Frequency Inverter with SmartStick Parameter Cloning

Commander SX →

Rugged IP66 / NEMA 4X Protected Inverter for Harsh Washdown Environments

HVAC Drive H300 →

Dedicated Building Automation Inverter with Embedded BACnet & Fire Mode Override

NE200 & NE300 →

Cost-Effective Open and Closed-Loop Sensorless Vector General Purpose Inverters

Powerdrive F300 →

High-Power Modular Fan, Pump & Compressor Inverter up to 2.8 MW (Modular Power)

Pump Drive F600 →

Dedicated Water & Wastewater Inverter with Multi-Pump Assist & Pipe Fill Intelligence

Unidrive HS30 →

High-Speed Frequency Inverter Supporting Up to 3,000 Hz Output Frequency

Unidrive HS70 →

Ultra-High Speed Inverter for Centrifugal Compressors, Test Benches & Spindles

Unidrive M100 →

Value AC Drive for Open-Loop Applications with Fast Parameter Setup

Unidrive M200 →

Standard Open-Loop Machinery Drive with Flexible SI Option Module Connectivity

Unidrive M300 →

Machinery Open-Loop AC Drive with Dual Integrated Safe Torque Off (SIL3/PLe)

Unidrive M400 →

Advanced Open-Loop Inverter with On-Board PLC (CODESYS) & Multi-Line Display

Unidrive M600 →

High-Performance Vector Drive with Sensorless Permanent Magnet Motor Control (RFC-S)

Unidrive M700 →

Flagship Universal AC & Servo Drive with Real-Time Ethernet & Advanced Motion Control

Unidrive SP →

Legendary Universal Industrial Inverter Platform Supporting AC Induction & Servo Motors

Digitax AC Servo Drives & Motion Systems

5 Models

Most Common Control Techniques Trip Codes

Diagnostic Quick Reference
Trip String Trip No. Trip Description Common Root Cause
OI.AC 1 Instantaneous Output Overcurrent Peak instantaneous current limit exceeded; short circuit across motor terminals (U, V, W), jammed mechanism, or high motor inertia.
OV 2 DC Bus Overvoltage Intermediate DC bus voltage exceeded trip threshold; rapid deceleration without braking resistor, or defective braking transistor.
UU 3 DC Bus Undervoltage DC link voltage dropped below operating threshold; mains power interruption, blown incoming branch fuse, or severe AC voltage sag.
OI.SC 8 Drive Output Short Circuit Direct low-impedance short circuit detected at inverter motor output or earth leakage; verify phase-to-phase and phase-to-ground resistance.
It.AC 6 Inverter Thermal Overload (I²t) Continuous current exceeded drive rated capacity over time; inspect mechanical binding or improper motor nameplate configuration.
OHt.Inverter 21 Heatsink Over-Temperature Heatsink or power module temperature sensor exceeded trip limit; blocked airflow louvers, failing cooling fan, or high enclosure ambient (>50°C).
PH.Lo 32 Input Phase Loss High DC link voltage ripple detected due to an open phase on the AC line power supply or an unseated disconnect switch contact.

How to Clear & Reset Control Techniques Trips

  1. Keypad Reset: Press the red STOP / RESET key directly on the front-mounted keypad or remote CI-Keypad.
  2. Digital Input Terminal: Apply a momentary 24VDC pulse to the digital input configured for drive reset (default Terminal T5 or parameter Pr 10.038 / Pr 10.38).
  3. Connect / Machine Control Studio Software: Connect via USB (CT Comms Cable) or Ethernet and click the “Reset Drive” button on the dashboard toolbar.
  4. Power Disconnect Cycle: Remove main 3-phase AC power, wait 5 minutes until the display goes completely blank and DC bus capacitors fully discharge, and restore power.
⚠️ High-Voltage Safety Warning: Hazardous electrical voltages up to 1,000 VDC remain present across the intermediate DC bus capacitors after mains supply disconnection. Wait at least 5 to 10 minutes and use a calibrated digital multimeter across terminals (+DC) and (-DC) to confirm the voltage is strictly below 50VDC before inspecting internal connections or motor terminals.