Allen-Bradley Drives Fault Codes & Troubleshooting
Complete diagnostic database for 24 Allen-Bradley PowerFlex & Kinetix drive series. Browse fault codes, alarms, causes, and step-by-step fixes for AC, DC, and servo motion controllers. Select your drive model series below to access parameter checks, root cause analysis, and physical inspection workflows.
PowerFlex AC Variable Frequency Drives
11 ModelsCost-Effective Standalone Drive with MainsFree USB Programming Configuration
Standard Compact Machinery Drive with Embedded EtherNet/IP & Safe Torque Off
Integrated CIP Motion Drive Exclusively Configured with Studio 5000 Logix
Space-Saving Micro Drive with Feed-Through Wiring for Compact Enclosures
Classic Economical Component Micro Drive for Basic Speed Regulation
Sensorless Vector Control AC Inverter with Auto-Tuning & Dynamic Braking
Category 3 Safe-Off Closed-Loop Machinery Drive for Machine Guarding
Dedicated HVAC & Centrifugal Fan/Pump Drive with Damper Control & Staging
High-Performance Heavy Industrial Vector Drive with Cassette Control Architecture
Compact Package Architecture Inverter with Integrated EMC Filtering & FORCE Control
Flagship Modular Industrial AC Drive Platform (PowerFlex 753 & 755 Architecture)
PowerFlex Industrial DC Drives
1 ModelKinetix Servo & Motion Drives
12 ModelsCompact Component Servo Drive for Small Point-to-Point Industrial Machines
EtherNet/IP Indexing Servo Drive for Standalone Multi-Positioning Systems
Integrated CIP Motion Drive Connecting Directly over Standard EtherNet/IP
Low-Power Multi-Axis Integrated Motion Servo Drive System with SERCOS Interface
Classic Digital Multi-Axis Servo Drive with Analog, Indexing & SERCOS Modules
Standard Integrated CIP Motion Servo Inverter for Small-to-Medium Production Lines
Shared AC/DC Bus Servo Drive with Single-Cable Technology & Dual-Port Ethernet
High-Axis Density Dual-Axis Servo System with Integrated Advanced Safety Over Network
Modular Multi-Axis SERCOS Servo System for High-Speed Packaging & Converting
Modular Multi-Axis Drive with Safe Speed & Safe Direction Monitoring Intelligence
Modular High-Performance Servo Drive Featuring CIP Motion directly on EtherNet/IP
High-Power Multi-Axis Servo System Up to 150 kW for Heavy Converting & Presses
Most Common PowerFlex & Kinetix Fault Codes
Diagnostic Quick Reference| PowerFlex Code | Kinetix Code | Fault Name | Common Root Cause |
|---|---|---|---|
| F012 / F12 | FLT M01 / E12 | HW OverCurrent | Drive hardware peak current limit exceeded due to motor short circuit, bound shaft, or aggressive acceleration. |
| F005 / F5 | FLT M02 / E02 | DC Bus OverVoltage | DC link voltage exceeded maximum trip threshold; motor regenerative power excessive during deceleration ramp. |
| F004 / F4 | FLT M03 / E03 | DC Bus UnderVoltage | DC bus voltage dropped below minimum threshold; utility voltage drop, missing incoming line phase, or blown branch fuse. |
| F013 / F13 | FLT M04 / E14 | Ground Fault | Current path detected from motor output terminals U, V, or W to protective earth; cracked insulation or motor moisture. |
| F007 / F7 | FLT M05 / E06 | Motor Overload | Continuous motor current exceeded motor rated nameplate Full Load Amps (FLA) according to thermal I²t curve. |
| F033 / F33 | FLT M18 | Auto Rstrt Tries | Drive unsuccessful in clearing fault condition after reaching maximum programmed automatic restart attempts. |
How to Clear & Reset Allen-Bradley Faults
- Keypad / HIM Reset: Press the red STOP button directly on the integral keypad or Human Interface Module (HIM) panel.
- Studio 5000 / Logix Command: Inside Studio 5000 Logix Designer or Connected Components Workbench (CCW), access the drive properties Add-On Profile (AOP) and click “Clear Fault” (or trigger a Motion Axis Fault Reset
MAFRinstruction). - Digital Input Pulse: Send a 24VDC pulse to the digital input configured for Clear Fault (e.g., Parameter t062–t068 set to option
1 "Clear Fault"on PowerFlex 520-series). - Power Disconnect Cycle: Remove main 3-phase line AC power, wait 5 minutes until all internal status LEDs and the DC bus charge indicator completely discharge, and reclose the circuit breaker.