Allen-Bradley Kinetix 5300 drive

Home / Allen-Bradley / Allen-Bradley Kinetix 5300 drive

Allen-Bradley Kinetix 5300 Drive Fault Codes & Diagnostic Guide

Complete fault code reference directory, trip alarm causes, and step-by-step diagnostic procedures for Rockwell Automation Allen-Bradley Kinetix 5300 single-axis EtherNet/IP servo drives. Search or filter through the complete diagnostic directory below.

CIP Motion on EtherNet/IP Power: 0.05 to 7.5 kW (50W to 7.5 kW) Hardwired Safe Torque Off (STO)
Power Range 0.05 – 7.5 kW (50W – 7.5 kW)
Supply Voltage 115V / 230V / 480V AC
Motion Control CIP Motion on EtherNet/IP
Operator Interface Studio 5000 Logix Designer

Complete Allen-Bradley Kinetix 5300 Drive Fault Code Directory

Use the search box in the table below to quickly find your code (e.g., type FLT M04, FLT S05, Overcurrent, or STO).

Fault Code and MeaningCause and Remedy
F02

Motor Commutation Fault

Cause:

Motor Commutation Fault detected.



Remedy:


  • Best Available Stopping Action: Disable/Coast.

  • Fault Action: Major Fault (Not configurable).


F03

Motor Overspeed Factory Limit Fault

Cause:

Motor Overspeed Factory Limit Fault.

Note: The loss of A/B signals from a TTL encoder isn't detected directly. Typically detected through excessive position/velocity error or motor overspeed.



Remedy:


  • Best Available Stopping Action: Disable/Coast.

  • Fault Action: Major Fault (Not configurable).


F04

Motor Overspeed User Limit Fault

Cause:

Motor Overspeed User Limit Fault.

Note: The loss of A/B signals from a TTL encoder isn't detected directly.



Remedy:


  • Best Available Stopping Action: Ramped Decel/Hold (Available in Velocity Control mode).

  • Fault Action: Configurable (Ignore, Alarm, Minor Fault, Major Fault).


F05

Motor Overtemperature Factory Limit Fault

Cause:

Motor Overtemperature Factory Limit Fault.



Remedy:


  • If #589 vertical load control: Current Decel/Disable.

  • If not #589 vertical load control: Disable/Coast.

  • Fault Action: Major Fault.


F07

Motor Thermal Overload Factory Limit Fault

Cause:

Motor Thermal Overload Factory Limit Fault.



Remedy:


  • Best Available Stopping Action: Ramped Decel/Disable (Available in Velocity Control mode).

  • Fault Action: Major Fault.


F08

Motor Thermal Overload User Limit Fault

Cause:

Motor Thermal Overload User Limit Fault.



Remedy:


  • Best Available Stopping Action: Ramped Decel/Hold (Available in Velocity Control mode).

  • Fault Action: Configurable (Ignore, Alarm, Minor Fault, Major Fault).


F09

Motor Phase Loss

Cause:

Motor Phase Loss detected.



Remedy:


  • Best Available Stopping Action: Disable/Coast.

  • Fault Action: Configurable (Ignore, Alarm, Minor Fault, Major Fault).


F10

Inverter Overcurrent Fault

Cause:

Inverter Overcurrent Fault.



Remedy:


  • Best Available Stopping Action: Disable/Coast.

  • Fault Action: Major Fault.


F11

Inverter Overtemperature Factory Limit Fault

Cause:

Inverter Overtemperature Factory Limit Fault.



Remedy:


  • If #589 vertical load control: Current Decel/Disable.

  • If not #589 vertical load control: Disable/Coast.

  • Fault Action: Major Fault.


F13

Inverter Thermal Overload Factory Limit Fault

Cause:

Inverter Thermal Overload Factory Limit Fault.



Remedy:


  • Best Available Stopping Action: Current Decel/Disable.

  • Fault Action: Major Fault.


F14

Inverter Thermal Overload User Limit Fault

Cause:

Inverter Thermal Overload User Limit Fault.



Remedy:


  • Best Available Stopping Action: Ramped Decel/Hold.

  • Fault Action: Configurable (Ignore, Alarm, Minor Fault, Major Fault).


F15

Converter Overcurrent Fault

Cause:

Converter Overcurrent Fault.



Remedy:


  • Best Available Stopping Action: Disable/Coast.

  • Fault Action: Major Fault.


F18

Converter OverTemp Factory Limit Fault

Cause:

Converter OverTemp Factory Limit Fault.



Remedy:


  • Best Available Stopping Action: Disable/Coast.

  • Fault Action: Major Fault.


F20

Converter Thermal Overload Factory Limit Fault

Cause:

Converter Thermal Overload Factory Limit Fault.



Remedy:


  • Best Available Stopping Action: Disable/Coast.

  • Fault Action: Major Fault.


F21

Converter Thermal Overload User Limit Fault

Cause:

Converter Thermal Overload User Limit Fault.



Remedy:


  • Best Available Stopping Action: Decel/Hold.

  • Fault Action: Configurable (Ignore, Alarm, Minor Fault, Major Fault).


F23

AC Single Phase Loss Fault

Cause:

AC Single Phase Loss Fault.



Remedy:


  • Best Available Stopping Action: Decel/Disable.

  • Fault Action: Configurable (Ignore, Alarm, Minor Fault, Major Fault).


F25

Pre-charge Failure Fault

Cause:

Pre-charge Failure Fault.



Remedy:


  • Best Available Stopping Action: Disable/Coast.

  • Fault Action: Major Fault.


F29

Bus Regulator Thermal Overload Factory Limit Fault

Cause:

Bus Regulator Thermal Overload Factory Limit Fault.



Remedy:


  • Best Available Stopping Action: Disable/Coast.

  • Fault Action: Major Fault.


F30

Bus Regulator Thermal Overload User Limit Fault

Cause:

Bus Regulator Thermal Overload User Limit Fault.



Remedy:


  • Best Available Stopping Action: Decel/Hold.

  • Fault Action: Configurable (Ignore, Alarm, Minor Fault, Major Fault).


F31

Bus Regulator Failure

Cause:

Bus Regulator Failure.



Remedy:


  • Best Available Stopping Action: Disable/Coast.

  • Fault Action: Major Fault.


F33

Bus Undervoltage Factory Limit Fault

Cause:

Bus Undervoltage Factory Limit Fault.



Remedy:


  • Best Available Stopping Action: Ramped Decel/Disable.

  • Fault Action: Major Fault.


F34

Bus Undervoltage User Limit Fault

Cause:

Bus Undervoltage User Limit Fault.



Remedy:


  • Best Available Stopping Action: Ramped Decel/Hold.

  • Fault Action: Configurable (Ignore, Alarm, Minor Fault, Major Fault).


F35

Bus Overvoltage Factory Limit Fault

Cause:

Bus Overvoltage Factory Limit Fault.



Remedy:


  • Best Available Stopping Action: Disable/Coast.

  • Fault Action: Major Fault.


F41

Feedback Signal Noise FL

Cause:

Feedback Signal Noise FL.



Remedy:


  • Best Available Stopping Action: Disable/Coast.

  • Fault Action: Major Fault.


F43

Feedback Signal Loss FL

Cause:

Feedback Signal Loss FL.



Remedy:


  • Best Available Stopping Action: Disable/Coast.

  • Fault Action: Major Fault.


F44

Feedback Signal Loss UL

Cause:

Feedback Signal Loss UL.



Remedy:


  • Best Available Stopping Action: Ramped Decel/Hold.

  • Fault Action: Configurable (Ignore, Alarm, Minor Fault, Major Fault).


F45

Motor Feedback Data Loss Factory Limit Fault

Cause:

Motor Feedback Data Loss Factory Limit Fault.

Note: Applies to Hiperface feedback devices.



Remedy:


  • Best Available Stopping Action: Disable/Coast.

  • Fault Action: Major Fault.


F46

Motor Feedback Data Loss User Limit Fault

Cause:

Motor Feedback Data Loss User Limit Fault.

Note: Applies to all compatible feedback devices.



Remedy:


  • Best Available Stopping Action: Ramped Decel/Hold.

  • Fault Action: Configurable (Ignore, Alarm, Minor Fault, Major Fault).


F47

Feedback Device Failure

Cause:

Feedback Device Failure.



Remedy:


  • Best Available Stopping Action: Disable/Coast.

  • Fault Action: Major Fault.


F49

Brake Slip Exception

Cause:

Brake Slip Exception.



Remedy:


  • Best Available Stopping Action: Ramped Decel/Hold.

  • Fault Action: Configurable (Ignore, Alarm, Minor Fault, Major Fault).


F50

Hardware Overtravel - Positive

Cause:

Hardware Overtravel - Positive.



Remedy:


  • Best Available Stopping Action: Ramped Decel/Hold.

  • Fault Action: Configurable (Ignore, Alarm, Minor Fault, Major Fault).


F51

Hardware Overtravel - Negative

Cause:

Hardware Overtravel - Negative.



Remedy:


  • Best Available Stopping Action: Ramped Decel/Hold.

  • Fault Action: Configurable (Ignore, Alarm, Minor Fault, Major Fault).


F54

Excessive Position Error Fault

Cause:

Excessive Position Error Fault.



Remedy:


  • If #589 vertical load control: Current Decel/Disable.

  • If not #589 vertical load control: Disable/Coast.

  • Fault Action: Configurable (Ignore, Alarm, Minor Fault, Major Fault).


F55

Excessive Velocity Error Fault

Cause:

Excessive Velocity Error Fault.



Remedy:


  • If #589 vertical load control: Current Decel/Disable.

  • If not #589 vertical load control: Disable/Coast.

  • Fault Action: Configurable (Ignore, Alarm, Minor Fault, Major Fault).


F56

Overtorque Limit Fault

Cause:

Overtorque Limit Fault.



Remedy:


  • Best Available Stopping Action: Ramped Decel/Hold.

  • Fault Action: Configurable (Ignore, Alarm, Minor Fault, Major Fault).


F57

Undertorque Limit Fault

Cause:

Undertorque Limit Fault.



Remedy:


  • Best Available Stopping Action: Ramped Decel/Hold.

  • Fault Action: Configurable (Ignore, Alarm, Minor Fault, Major Fault).


F61

Enable Input Deactivated

Cause:

Enable Input Deactivated.



Remedy:


  • Best Available Stopping Action: Ramped Decel/Disable.

  • Fault Action: Configurable (Ignore, Alarm, Minor Fault, Major Fault).


Fc02

Motor Voltage Mismatch Fault

Cause:

Motor Voltage Mismatch Fault.



Remedy:


  • Best Available Stopping Action: Disable/Coast.

  • Fault Action: Configurable (Ignore, Alarm, Minor Fault, Major Fault).


Fc05

Feedback Battery Loss Fault

Cause:

Feedback Battery Loss Fault.

Note: Applies to only Kinetix TLP or Kinetix TLY-Axxxx-B encoders.



Remedy:


  • Best Available Stopping Action: Disable/Coast.

  • Fault Action: Major Fault.


Fc06

Feedback Battery Low Fault

Cause:

Feedback Battery Low Fault.

Note: Applies to only Kinetix TLP or Kinetix TLY-Axxxx-B encoders.



Remedy:


  • Best Available Stopping Action: Disable/Coast.

  • Fault Action: Configurable (Ignore, Alarm, Minor Fault, Major Fault).


Fc07

Feedback Incremental Count Error Exception

Cause:

Feedback Incremental Count Error Exception.



Remedy:


  • Best Available Stopping Action: Disable/Coast.

  • Fault Action: Major Fault.


Fc16

PWM Frequency Reduced Exception

Cause:

PWM Frequency Reduced Exception.



Remedy:


  • Best Available Stopping Action: Disable/Coast.

  • Fault Action: Configurable (Ignore, Alarm, Minor Fault, Major Fault).


Fc26

Runtime Error

Cause:

Runtime Error.



Remedy:


  • Best Available Stopping Action: Disable/Coast.

  • Fault Action: Major Fault.


nF01

Control Connection Update Fault

Cause:

Control Connection Update Fault.



Remedy:


  • Best Available Stopping Action: Ramped Decel/Disable.

  • Fault Action: Major Fault.


nF02

Processor Watchdog Fault

Cause:

Processor Watchdog Fault.



Remedy:


  • Best Available Stopping Action: Disable/Coast.

  • Fault Action: Major Fault.


nF05

Clock Skew Fault

Cause:

Clock Skew Fault.



Remedy:


  • Best Available Stopping Action: Ramped Decel/Disable.

  • Fault Action: Major Fault.


nF06

Lost Controller Connection Fault

Cause:

Lost Controller Connection Fault.



Remedy:


  • Action: Programmable per Connection Loss Stopping Action.

  • Fault Action: Major Fault.


nF07

Clock Sync Fault

Cause:

Clock Sync Fault.



Remedy:


  • Best Available Stopping Action: Ramped Decel/Disable.

  • Fault Action: Major Fault.


nF09

Duplicate IP Address Fault

Cause:

Duplicate IP Address Fault.



Remedy:


  • Best Available Stopping Action: Disable/Coast.

  • Fault Action: Major Fault.


SF09

Guard Stop Input Fault

Cause:

Guard Stop Input Fault.



Remedy:


  • Best Available Stopping Action: Disable/Coast.

  • Fault Action: Major Fault.


How to Clear & Reset Allen-Bradley Kinetix 5300 Drive Faults

  1. Studio 5000 Logix Designer: Execute a Motion Axis Fault Reset (MAFR) or Motion Axis Stop Reset (MASR) instruction in ladder logic, or open the Axis Properties window and click “Clear Faults” under the Faults & Diagnostics tab.
  2. Verify Hardwired STO Safety Inputs: Ensure dual-channel Safe Torque Off inputs (terminals STO-1 and STO-2) receive 24VDC from your safety monitoring relay or safety PLC; an open STO circuit permanently latches safe-off trip conditions.
  3. Motion Direct Commands (MDC): In Studio 5000 online mode, open the Motion Direct Commands dialog for the axis, disable servo operation (MSF), and execute a Fault Reset (MASR).
  4. Clear Active Motion & Position Planner Errors: Stop motion profiling from the Logix controller and verify that motor feedback signals (encoders/resolvers) are stable before commanding an axis re-enable (MSO).
  5. Power Cycle (Control & Mains): Remove 24VDC auxiliary control logic power and AC mains input line power. Wait at least 5 minutes until the status display and indicator LEDs completely extinguish, then restore power.
⚠️ High-Voltage Electrical Safety Warning: Always verify with a calibrated digital multimeter that intermediate DC bus voltage measures strictly below 50VDC across terminals [+DC] and [-DC] before handling motor power output connections (U, V, W), internal/external shunt resistor wiring, or opening protective covers on the Kinetix 5300 drive.