Allen-Bradley Kinetix 300 Drive Fault Codes & Diagnostic Guide
Complete fault code reference directory, error LED indicator causes, and step-by-step diagnostic procedures for Allen-Bradley Kinetix 300 EtherNet/IP indexing servo drives. Search or filter through the complete diagnostic directory below.
Power Range
0.4 – 3.0 kW (400W – 3 kW)
Supply Voltage
115V / 230V / 480V AC
Motion Control
EtherNet/IP Indexing & Velocity
Operator Interface
Embedded Web Server & CCW
Complete Allen-Bradley Kinetix 300 Drive Fault Code Directory
Use the search box in the table below to quickly find your error code (e.g., type E04, E05, E14, or Overcurrent).
| Fault Code and Meaning | Cause and Remedy |
|---|---|
| - Status indicator not displaying any messages | Cause: No AC power or back-up power. Internal power supply malfunction. Remedy:
|
| - Motor jumps when first enabled | Cause: Motor wiring error. Incorrect motor chosen. Remedy:
|
| E04 Motor overtemperature | Cause: Motor thermostat trips due to: High motor ambient temperature or Excessive current. Motor wiring error. Incorrect motor selection. Remedy:
|
| E06 Hardware overtravel | Cause: Dedicated overtravel input is inactive. Remedy:
|
| E07 Feedback lost | Cause: The feedback wiring is open, shorted, or missing. Remedy:
|
| E09 Bus undervoltage | Cause: Low AC line/AC power input. Remedy:
|
| E10 Bus overvoltage | Cause: Excessive regeneration of power (motor driven by external source). Excessive AC input voltage. Remedy:
|
| E11 Illegal Hall state | Cause: Incorrect phasing. Bad connections. Remedy:
|
| E12 Home search failed | Cause: Home sensor and/or marker is outside the overtravel limits. Remedy:
|
| E14 Ethernet I/O connection lost | Cause: Ethernet I/O Connection lost. Remedy:
|
| E16 Software overtravel | Cause: Programmed overtravel limit has been exceeded. Remedy:
|
| E18 Overspeed fault | Cause: Motor speed has exceeded 125% of maximum rated speed. Remedy:
|
| E19 Excess position error | Cause: Position error limit was exceeded. Remedy:
|
| E23 Drive Thermal Protection | Cause: The internal filter algorithm protecting the drive from overheating has tripped. Remedy:
|
| E26 Index parameter out of range | Cause: Parameters that are specified in the index table are beyond system capabilities. Remedy:
|
| E27 Absolute move fault | Cause: Initiated move without being homed. Remedy:
|
| E30 Encoder communication fault | Cause: Communication was not established with an intelligent encoder. Remedy:
|
| E31 Encoder data | Cause: Encoder data is corrupted. Remedy:
|
| E39 Safe Torque Off while enabled | Cause: The safety circuit was opened while drive was enabled or while attempting to enable. Remedy:
|
| E43 Drive enable input | Cause: An attempt was made to enable the axis through software while the Drive Enable hardware input was inactive. The Drive Enable input transitioned from active to inactive while axis was enabled. Remedy:
|
| E44 Controller changed to PROG mode | Cause: Program downloaded or turned key on logix controller to program position. Remedy:
|
| E67 Operating system failed | Cause: Hardware or configuration failure. Remedy:
|
| E70 Memory module error | Cause: Bad memory module. Remedy:
|
| E72 Drive temperature too high | Cause: The heatsink temperature sensor has detected an overtemperature condition due to improper airflow or environmental temperature. Remedy:
|
| E74 Drive has exceeded peak current limit | Cause: Motor cables shorted. Motor winding shorted internally. Machine duty cycle requires RMS current exceeding rating. Operation above continuous power/env rating. Short circuit or failed component. Remedy:
|
| E76 Blank memory module | Cause: A Blank MEM module has been inserted into the drive. Remedy:
|
| E91 User watchdog has timed out | Cause: Ladder program error. Remedy:
|
| E92 Bad battery | Cause: Tamagawa absolute feedback battery voltage low or missing. Battery error at startup. Remedy:
|
| E93 Motion set-up parameters calculation error | Cause: Motion set-up parameters calculate an acceleration value above or below the drive capability. Remedy:
|
| E94 Motor or motor feedback cable | Cause: Motor or feedback device malfunction. Grounding instructions not followed. Remedy:
|
| E95 Wrong Indexing Mode | Cause: Index Type or ReferenceSource not supported in configured Linear/Rotary Unwind mode. Remedy:
|
How to Clear & Reset Allen-Bradley Kinetix 300 Drive Faults
- MotionView OnBoard (Web Browser): Type the drive’s assigned IP address into your web browser, navigate to the Drive Status dashboard, and click the “Clear Faults” button.
- Digital Input Reset: If an assigned digital input (IN1 through IN4 on the IOD terminal connector) is configured as
Fault Reset, pulse the input terminal with 24VDC to clear the latching condition. - Studio 5000 / CCW: Online via EtherNet/IP, issue an axis fault reset instruction (`MASR` or explicit reset message command) from your Logix controller program or through Connected Components Workbench.
- EtherNet/IP Logic Command Word: Transition the Fault Reset bit from `0` to `1` in the cyclic command output assembly tag across the EtherNet/IP network.
- Power Cycle (Control & Mains): Remove 24VDC logic control power and AC mains input power from the drive. Wait at least 5 minutes for the front 4-digit display to turn off completely and internal capacitors to discharge, then re-energize the drive.
⚠️ High-Voltage Electrical Safety Warning:
Always verify with a calibrated digital multimeter that the intermediate DC bus voltage measures strictly below 50VDC across terminals [+DC] and [-DC] before handling servo motor power wiring (U, V, W), internal shunt resistor leads, or opening terminal cover barriers on the Kinetix 300 drive.