Allen-Bradley Kinetix 3 servo drive

Home / Allen-Bradley / Allen-Bradley Kinetix 3 servo drive

Allen-Bradley Kinetix 3 Servo Drive Fault Codes & Diagnostic Guide

Complete fault code reference directory, trip alarm causes, and step-by-step troubleshooting procedures for the Allen-Bradley Kinetix 3 component servo drive series (Bulletin 2071). Search or filter through the complete fault code directory below.

Component Servo Drive (Bulletin 2071) Power: 50 W to 1.5 kW (0.05 to 1.5 kW) Indexing, Velocity & Torque Control
Power Range 0.05 – 1.5 kW (50 – 1500 W)
Supply Voltage 120V / 240V AC (1-Ph & 3-Ph)
Control Modes Position (Indexing), Velocity & Torque
Operator Interface 4-Digit Display / CCW / Modbus RTU

Complete Allen-Bradley Kinetix 3 Servo Drive Fault Code Directory

Use the search box in the table below to quickly find your code (e.g., type E03, E05, E14, or Overload).

Fault Code and MeaningCause and Remedy
Pot

Positive Overtravel

Cause:

A Positive Overtravel condition is detected.



Remedy:


  • Apply motion in a negative direction to move off of overtravel limit switch.


not

Negative Overtravel

Cause:

A Negative Overtravel condition is detected.



Remedy:


  • Apply motion in a positive direction to move off of overtravel limit switch.


Cnt

Absolute Encoder Counter Overflow

Cause:

The Absolute Encoder has exceeded its rotational limit.



Remedy:


  • Reset the absolute encoder.


bAt

Absolute Encoder Battery

Cause:

Low battery warning, less than 3.2V is being supplied.



Remedy:


  • Replace battery or verify external power supply.

  • (Note: Battery replacement causes loss of absolute position. Homing can be necessary).


PrE

Power Up Overspeed

Cause:

Control power is applied to the drive while the motor is in motion.



Remedy:


  • After verifying motor has stopped, recycle control power.


oCC

Over Current Command

Cause:

Improper setting of analog current scale.



Remedy:


  • Verify scaling parameter corresponds to analog signal range.





Cause:

System cannot meet motion profile.



Remedy:


  • Verify velocity loop tuning.

  • Verify system sizing.





Cause:

Incorrect current limit settings.



Remedy:


  • Verify current limits do not restrict current to less than system capabilities.


oSC

Over Speed Command

Cause:

Improper setting of analog velocity scale.



Remedy:


  • Verify scaling parameter corresponds to analog signal range.





Cause:

System cannot meet motion profile.



Remedy:


  • Verify position loop tuning.

  • Verify system sizing.


PIn

Digital I/O Assignment

Cause:

Inappropriate assignment of digital inputs or outputs.



Remedy:


  • If operated in preset mode, verify presets are assigned.

  • If operated in a normal/override mode, verify the override function is assigned.


CAP

Motor Over Rated Output Power

Cause:

Motor rating larger than drive rating.



Remedy:


  • Match motor and drive sizing.


E004 (Entrot)

Motor Overtemperature

Cause:

Motor thermal switch trips due to: High motor ambient temperature or Excessive current.



Remedy:


  • Operate within (not above) the continuous torque rating for the ambient temperature.

  • Lower ambient temperature, or increase motor cooling.





Cause:

Motor wiring error.



Remedy:


  • Check motor wiring.





Cause:

Incorrect motor selection.



Remedy:


  • Verify the proper motor has been selected.


E005 (EIPMFL)

IPM Error

Cause:

Motor power cables shorted.



Remedy:


  • Verify continuity of motor power cable and connector.





Cause:

Motor winding shorted internally.



Remedy:


  • Disconnect motor power cables from the motor. If the motor is difficult to turn by hand, it can need to be replaced.





Cause:

Operation above continuous power rating.



Remedy:


  • Verify ambient temperature is not too high.

  • Operate within the continuous power rating.

  • Reduce acceleration rates.





Cause:

Drive has a bad IPM output, short circuit, or overcurrent.



Remedy:


  • Remove all power and motors connections, then perform a continuity check from the DC bus to the U, V, and W motor terminals.

  • If continuity exists, check for wire strands between terminals, or replace the drive.


E009 (Eudolt)

Bus Undervoltage

Cause:

Low AC line/AC power input.



Remedy:


  • Verify voltage level of the incoming AC power.

  • Check AC power sources for glitches or line drop.

  • Install uninterruptible power supply (UPS) on the AC input.





Cause:

Attempted to enable drive without main power active.



Remedy:


  • Apply main power before enabling drive.


E010 (Eouolt)

Bus Overvoltage

Cause:

Excessive regeneration of power (motor driven by external force/regenerating too much peak energy).



Remedy:


  • Verify shunt circuit.

  • Adjust motion profile to stay within the range of the regenerative resistor.

  • Replace regenerative transistor.

  • Replace the drive.





Cause:

Excessive AC input voltage.



Remedy:


  • Verify input is within specification.


E012 (EHFAiL)

Home Search Failed

Cause:

Homing is not complete within the time defined in Homing time limit (IN-01.11) is elapsed.



Remedy:


  • Increase the time defined in Homing time limit (IN-01.11).

  • Set a value other than '0' in Homing Velocity (IN-01.02) and Creep Velocity (IN-01.03).

  • Check if there is any obstacle that disturbs Homing.

  • Check mechanical parts and parameter settings for Homing.


E018 (EovSPd)

Motor Overspeed

Cause:

Motor speed exceeds maximum.



Remedy:


  • Confirm encoder wiring.

  • Retune drive system.

  • Verify input gain of external speed or torque command.


E019 (EPoSEr)

Excess Position Error

Cause:

Position error exceeds permitted value.



Remedy:


  • Increase following error limit.

  • Check position loop tuning.


E022

Motor Continuous Current Overload

Cause: The internal filter protecting the motor from overheating has tripped.



Remedy:


  • Reduce acceleration rates.

  • Reduce duty cycle (ON/OFF) of commanded motion.

  • Increase time permitted for motion.

  • Use larger drive and motor.

  • Check tuning.


E023

Drive Overload

Cause: The motion application requires average drive current in excess of rated capability.



Remedy:


  • Reduce acceleration rates.

  • Reduce duty cycle (ON/OFF) of commanded motion.

  • Increase time permitted for motion.

  • Use larger drive and motor.

  • Check tuning.


E028

Encoder Data Range Error

Cause: Encoder not programmed correctly or Encoder memory corrupted.



Remedy:


  • Replace motor.


E030

Encoder Cable Open

Cause: Communication not established with an intelligent encoder, Hall error, or encoder wiring issue.



Remedy:


  • Verify motor selection if it does not support automatic identification.

  • Verify the motor supports automatic identification.

  • Verify encoder wiring.


E031

Encoder Data Parameter Error

Cause: Encoder not programmed correctly or Encoder memory corrupted.



Remedy:


  • Replace motor.


E036

Drive Overtemperature

Cause: Excessive heat exists in the drive.



Remedy:


  • Verify cooling fan operation (catalog numbers 2071-AP8, 2071-A10, and 2071-A15 only).

  • Check tuning.

  • Reduce acceleration rate.

  • Reduce duty cycle (ON/OFF) of commanded motion.

  • Increase time permitted for motion.

  • Use larger drive and motor.


E037

AC Line Loss

Cause: Poor quality power, attempted enable without main power, missing phase connection, or Fault Delay too short.



Remedy:


  • Increase Ride Through time.

  • Apply main power before enabling drive.

  • Remove power and verify all physical connections.

  • Increase the Fault Delay parameter setting.


E053

User Parameter Initialization Error

Cause: Error in parameter memory storage.



Remedy:


  • Reinitialize parameter.

  • Reset drive to factory defaults.


E054

Current Feedback Offset

Cause: Defective hardware.



Remedy:


  • Replace the drive.


E055

User Parameter Checksum Error

Cause: Checksum error.



Remedy:


  • Confirm and reset parameter.

  • Reset drive to factory defaults.


E056

Watchdog Timeout

Cause: Excessive electrical noise or Defective hardware.



Remedy:


  • Verify wiring, grounding and bonding.

  • Replace the drive.


E057

PWM Hardware Error

Cause: Defective hardware.



Remedy:


  • Replace the drive.


E058

User Parameter Range Error

Cause: Range of parameter is invalid.



Remedy:


  • Enter parameter with a value or values within range.

  • Reset drive to factory defaults.


E060

Drive Initialization Error

Cause: Hardware error.



Remedy:


  • Replace the drive.


E075

Shunt Overload Protection

Cause: Power at regenerative resistor exceeds permitted value, or Shunt resistor is disconnected/damaged.



Remedy:


  • Adjust motion profile to stay within the range of the regenerative resistor.

  • Verify resistor connection.

  • Verify resistance of shunt resistor.


E079

Shunt Overcurrent Protection

Cause: Shunt current exceeded allowable instantaneous value.



Remedy:


  • Verify shunt is not shorted or damaged.

  • Verify load energy is not excessive during deceleration.


E083

Absolute Encoder Battery Error

Cause: Encoder Backup Battery parameter is set to installed but battery is missing, or battery voltage is below 2.7V DC.



Remedy:


  • Set Encoder Backup Battery parameter to Not Installed (if applicable).

  • Confirm battery voltage and connection.

  • Replace battery.


E084

Absolute Encoder Overspeed

Cause: Battery powered encoder is mechanically rotated at high speed while drive is powered down.



Remedy:


  • Mechanically disengage motor from system.

  • Cycle power to drive and reset alarm.


E085

Absolute Encoder Multi-turn Count Error

Cause: Electrical noise in the encoder or Defective encoder.



Remedy:


  • Cycle power to drive and reset alarm.

  • Replace motor.


E100

Drive Set Up

Cause: The drive operating mode and motor selection are incompatible.



Remedy:


  • Change the operating mode and/or the motor selection, and reset the drive.


E101

Motor Power Cable Open

Cause: Motor cable open.



Remedy:


  • Verify power connection between motor and drive.


E102

Motor Instantaneous Current Overload

Cause: Motion profile requires a peak current for an excessive time interval or Defective current feedback sensing.



Remedy:


  • Verify motor wiring.

  • Adjust accel/decel time.

  • Confirm motor selection.

  • Verify phase currents.


E103

Motor Mismatch

Cause: Dynamic braking current of the selected motor exceeds twice the drive peak current rating.



Remedy:


  • Install a different motor.


E105

Encoder Type Mismatch

Cause: Motor encoder signals do not match drive configuration or Defective encoder.



Remedy:


  • Verify motor selection.

  • Replace motor.


E106

Encoder Communication Error

Cause: Wiring between drive and encoder is faulty or disconnected, or EMI (noise) disrupts encoder signals.



Remedy:


  • Verify encoder wiring.


E107

Special Communication Error

Cause: Communication error between host and drive (noise).



Remedy:


  • Verify serial cable.

  • Check for noise on serial communication interface.


E108

Position Command Frequency Error

Cause: Input frequency limit exceeded.



Remedy:


  • Verify hardware type selected in the drive matches the physical hardware.

  • Change from open collector to line drive.

  • Reduce the speed command.

  • Apply gearing.


E112

Emergency Stop

Cause: Emergency stop (E-STOP) signal detected.



Remedy:


  • Remove Emergency stop conditions.

  • Clear E-STOP.


E113

Index Position Range Overflow

Cause: The value of a Position Parameter for indexing is out of the range.



Remedy:


  • Use a value within the range of -231...+231.


E114

Motor Phase Over Current

Cause: Anomaly with control/main power circuitry upon power up, or excessive current to motor (>300% rated for >10ms) during operation.



Remedy:


  • Check wiring and power.

  • Check power and set/adjust acceleration/deceleration time.


E027

Axis Not Homed

Cause: A user tries any indexing without Homing operation completed.



Remedy:


  • Complete homing before indexing.


How to Clear & Reset Allen-Bradley Kinetix 3 Drive Faults

  1. Digital Input Reset (Alarm Reset): Pulse the digital input terminal assigned to the Alarm Reset (ARST) function on the I/O signal connector (IOD). Maintain the reset signal active for at least 100 ms to clear the condition.
  2. Software Reset (CCW / Ultraware): Connect your computer to the drive’s serial port (RS-232 / RS-485), open Connected Components Workbench (CCW) or Ultraware software, launch the Kinetix 3 Startup Wizard, and click “Reset Drive”.
  3. Front Display / Pushbutton Reset: Use the four navigation push buttons beneath the 4-digit LED status display to navigate to the fault monitor parameter, then press and hold the Enter/Set key to acknowledge and reset non-fatal error codes.
  4. Serial Host Command (Modbus RTU / ASCII): Write the fault clear command via the communication interface from your master controller (e.g., Micro800 PLC) to clear active drive alarms over serial network logic.
  5. Power Cycle: Disconnect AC line input power to the drive. Wait until the 4-digit LED display completely shuts off (allow at least 3 to 5 minutes for intermediate DC bus capacitors to discharge safely below 50VDC), then re-apply input power.
⚠️ High-Voltage Electrical Safety Warning: Always verify with a calibrated digital multimeter that intermediate DC bus voltage measures strictly below 50VDC across terminals [+DC] and [-DC] (or shunt resistor terminals) before inspecting motor feedback cables, servicing motor power wiring, or touching motor terminals U, V, and W on the Kinetix 3 servo drive.