Allen-Bradley Kinetix 3 Servo Drive Fault Codes & Diagnostic Guide
Complete fault code reference directory, trip alarm causes, and step-by-step troubleshooting procedures for the Allen-Bradley Kinetix 3 component servo drive series (Bulletin 2071). Search or filter through the complete fault code directory below.
Power Range
0.05 – 1.5 kW (50 – 1500 W)
Supply Voltage
120V / 240V AC (1-Ph & 3-Ph)
Control Modes
Position (Indexing), Velocity & Torque
Operator Interface
4-Digit Display / CCW / Modbus RTU
Complete Allen-Bradley Kinetix 3 Servo Drive Fault Code Directory
Use the search box in the table below to quickly find your code (e.g., type E03, E05, E14, or Overload).
| Fault Code and Meaning | Cause and Remedy |
|---|---|
| Pot Positive Overtravel | Cause: A Positive Overtravel condition is detected. Remedy:
|
| not Negative Overtravel | Cause: A Negative Overtravel condition is detected. Remedy:
|
| Cnt Absolute Encoder Counter Overflow | Cause: The Absolute Encoder has exceeded its rotational limit. Remedy:
|
| bAt Absolute Encoder Battery | Cause: Low battery warning, less than 3.2V is being supplied. Remedy:
|
| PrE Power Up Overspeed | Cause: Control power is applied to the drive while the motor is in motion. Remedy:
|
| oCC Over Current Command | Cause: Improper setting of analog current scale. Remedy:
Cause: System cannot meet motion profile. Remedy:
Cause: Incorrect current limit settings. Remedy:
|
| oSC Over Speed Command | Cause: Improper setting of analog velocity scale. Remedy:
Cause: System cannot meet motion profile. Remedy:
|
| PIn Digital I/O Assignment | Cause: Inappropriate assignment of digital inputs or outputs. Remedy:
|
| CAP Motor Over Rated Output Power | Cause: Motor rating larger than drive rating. Remedy:
|
| E004 (Entrot) Motor Overtemperature | Cause: Motor thermal switch trips due to: High motor ambient temperature or Excessive current. Remedy:
Cause: Motor wiring error. Remedy:
Cause: Incorrect motor selection. Remedy:
|
| E005 (EIPMFL) IPM Error | Cause: Motor power cables shorted. Remedy:
Cause: Motor winding shorted internally. Remedy:
Cause: Operation above continuous power rating. Remedy:
Cause: Drive has a bad IPM output, short circuit, or overcurrent. Remedy:
|
| E009 (Eudolt) Bus Undervoltage | Cause: Low AC line/AC power input. Remedy:
Cause: Attempted to enable drive without main power active. Remedy:
|
| E010 (Eouolt) Bus Overvoltage | Cause: Excessive regeneration of power (motor driven by external force/regenerating too much peak energy). Remedy:
Cause: Excessive AC input voltage. Remedy:
|
| E012 (EHFAiL) Home Search Failed | Cause: Homing is not complete within the time defined in Homing time limit (IN-01.11) is elapsed. Remedy:
|
| E018 (EovSPd) Motor Overspeed | Cause: Motor speed exceeds maximum. Remedy:
|
| E019 (EPoSEr) Excess Position Error | Cause: Position error exceeds permitted value. Remedy:
|
| E022 Motor Continuous Current Overload | Cause: The internal filter protecting the motor from overheating has tripped. Remedy:
|
| E023 Drive Overload | Cause: The motion application requires average drive current in excess of rated capability. Remedy:
|
| E028 Encoder Data Range Error | Cause: Encoder not programmed correctly or Encoder memory corrupted. Remedy:
|
| E030 Encoder Cable Open | Cause: Communication not established with an intelligent encoder, Hall error, or encoder wiring issue. Remedy:
|
| E031 Encoder Data Parameter Error | Cause: Encoder not programmed correctly or Encoder memory corrupted. Remedy:
|
| E036 Drive Overtemperature | Cause: Excessive heat exists in the drive. Remedy:
|
| E037 AC Line Loss | Cause: Poor quality power, attempted enable without main power, missing phase connection, or Fault Delay too short. Remedy:
|
| E053 User Parameter Initialization Error | Cause: Error in parameter memory storage. Remedy:
|
| E054 Current Feedback Offset | Cause: Defective hardware. Remedy:
|
| E055 User Parameter Checksum Error | Cause: Checksum error. Remedy:
|
| E056 Watchdog Timeout | Cause: Excessive electrical noise or Defective hardware. Remedy:
|
| E057 PWM Hardware Error | Cause: Defective hardware. Remedy:
|
| E058 User Parameter Range Error | Cause: Range of parameter is invalid. Remedy:
|
| E060 Drive Initialization Error | Cause: Hardware error. Remedy:
|
| E075 Shunt Overload Protection | Cause: Power at regenerative resistor exceeds permitted value, or Shunt resistor is disconnected/damaged. Remedy:
|
| E079 Shunt Overcurrent Protection | Cause: Shunt current exceeded allowable instantaneous value. Remedy:
|
| E083 Absolute Encoder Battery Error | Cause: Encoder Backup Battery parameter is set to installed but battery is missing, or battery voltage is below 2.7V DC. Remedy:
|
| E084 Absolute Encoder Overspeed | Cause: Battery powered encoder is mechanically rotated at high speed while drive is powered down. Remedy:
|
| E085 Absolute Encoder Multi-turn Count Error | Cause: Electrical noise in the encoder or Defective encoder. Remedy:
|
| E100 Drive Set Up | Cause: The drive operating mode and motor selection are incompatible. Remedy:
|
| E101 Motor Power Cable Open | Cause: Motor cable open. Remedy:
|
| E102 Motor Instantaneous Current Overload | Cause: Motion profile requires a peak current for an excessive time interval or Defective current feedback sensing. Remedy:
|
| E103 Motor Mismatch | Cause: Dynamic braking current of the selected motor exceeds twice the drive peak current rating. Remedy:
|
| E105 Encoder Type Mismatch | Cause: Motor encoder signals do not match drive configuration or Defective encoder. Remedy:
|
| E106 Encoder Communication Error | Cause: Wiring between drive and encoder is faulty or disconnected, or EMI (noise) disrupts encoder signals. Remedy:
|
| E107 Special Communication Error | Cause: Communication error between host and drive (noise). Remedy:
|
| E108 Position Command Frequency Error | Cause: Input frequency limit exceeded. Remedy:
|
| E112 Emergency Stop | Cause: Emergency stop (E-STOP) signal detected. Remedy:
|
| E113 Index Position Range Overflow | Cause: The value of a Position Parameter for indexing is out of the range. Remedy:
|
| E114 Motor Phase Over Current | Cause: Anomaly with control/main power circuitry upon power up, or excessive current to motor (>300% rated for >10ms) during operation. Remedy:
|
| E027 Axis Not Homed | Cause: A user tries any indexing without Homing operation completed. Remedy:
|
How to Clear & Reset Allen-Bradley Kinetix 3 Drive Faults
- Digital Input Reset (Alarm Reset): Pulse the digital input terminal assigned to the Alarm Reset (ARST) function on the I/O signal connector (IOD). Maintain the reset signal active for at least 100 ms to clear the condition.
- Software Reset (CCW / Ultraware): Connect your computer to the drive’s serial port (RS-232 / RS-485), open Connected Components Workbench (CCW) or Ultraware software, launch the Kinetix 3 Startup Wizard, and click “Reset Drive”.
- Front Display / Pushbutton Reset: Use the four navigation push buttons beneath the 4-digit LED status display to navigate to the fault monitor parameter, then press and hold the Enter/Set key to acknowledge and reset non-fatal error codes.
- Serial Host Command (Modbus RTU / ASCII): Write the fault clear command via the communication interface from your master controller (e.g., Micro800 PLC) to clear active drive alarms over serial network logic.
- Power Cycle: Disconnect AC line input power to the drive. Wait until the 4-digit LED display completely shuts off (allow at least 3 to 5 minutes for intermediate DC bus capacitors to discharge safely below 50VDC), then re-apply input power.
⚠️ High-Voltage Electrical Safety Warning:
Always verify with a calibrated digital multimeter that intermediate DC bus voltage measures strictly below 50VDC across terminals [+DC] and [-DC] (or shunt resistor terminals) before inspecting motor feedback cables, servicing motor power wiring, or touching motor terminals U, V, and W on the Kinetix 3 servo drive.