Lenze

Home / Lenze

Lenze Drives Fault Codes & Troubleshooting

Complete diagnostic database for 24 Lenze drive series. Browse fault codes, trip errors, causes, and step-by-step fixes for industrial AC variable speed inverters and high-performance servo motion amplifiers. Select your drive model series below to access parameter checks, root cause analysis, and physical inspection workflows.

16 AC Inverter Series 8 Servo Motion Drives 24 Total Series

Lenze AC Drives & Inverters

16 Models
8200 Motec →

Decentralized IP65 Motor-Mounted Frequency Inverter for Distributed Automation

8200 Vector →

Modular Classic Vector Frequency Inverter with Plug-In Function Modules

8400 BaseLine →

Compact Entry-Level Inverter for Basic Controlled Motion & Conveyor Systems

8400 StateLine →

Universal Frequency Inverter with Integrated Logic Control & Point-to-Point Positioning

9300 Vector →

Heavy-Duty Vector Control Inverter for Complex Production & Material Web Handling

MC 1000 →

Classic Compact Micro Inverter for Low-Power Conveyors & Packaging Machines

MC 3000 →

Robust General-Purpose Frequency Converter for Centrifugal Pumps & Blowers

SCF Series →

Compact Sub-Micro Frequency Inverter with Quick Parameter Memory Technology

SCL Series →

DIN-Rail Mounted Sub-Compact AC Drive for Fractional Horsepower Motor Regulation

SCM Series →

Sub-Micro Drive Featuring EPM (Electronic Programmable Module) Chip Architecture

SM Vector →

Dynamic Sensorless Flux Vector Inverter Available in NEMA 1 (IP31) & NEMA 4X (IP65)

SMD Series →

Cost-Effective Micro Drive with Simple Dial Operation & Fast EPM Programming

i510 Cabinet →

Slim Booksize Space-Saving Inverter (0.25 to 15 kW) for Cabinet Machine Integration

i550 Cabinet →

Versatile Industrial Inverter Supporting Multi-Fieldbus, Integrated STO & Vector Control

i550 Motec →

Rugged Decentralized IP66 Motor-Mounted Inverter with IO-Link & Energy Regeneration

i550 Protec →

High IP-Protection (IP66) Wall-Mount Inverter for Extreme Wet & Dusty Factory Environments

Lenze Servo Drives & Motion Systems

8 Models

Most Common Lenze Drive Fault Codes

Diagnostic Quick Reference
Fault Code Hex / CANopen Fault Description Common Root Cause
OC1 / OC2 0x2310 Short Circuit / Overcurrent Peak instantaneous motor current exceeded; phase-to-phase short on U, V, W, mechanical jam, or damaged motor windings.
OU 0x3210 DC Bus Overvoltage DC link voltage exceeded upper trip threshold; rapid deceleration without braking resistor or regenerative overhauling load.
LU 0x3220 DC Bus Undervoltage DC link voltage dropped below allowable limit; mains power blackout, utility phase dip, or blown line protection fuse.
OH / OH1 0x4310 Heatsink Over-Temperature Internal power module temperature exceeded safety limits; clogged heatsink fins, cooling fan failure, or high ambient (>50°C).
OC6 0x2330 Ground / Earth Fault Current leakage detected from motor output phases to protective earth (PE); degraded cable jacket or damp motor terminals.
CE0 / CE1 0x8100 Communication Error Fieldbus watchdog timeout (CANopen, EtherCAT, PROFINET); severed communication cable, bus noise, or master PLC cycle stop.
OL 0x7122 Motor Thermal Overload (I²t) Sustained operation above continuous rated Full Load Amps (FLA); mechanical binding or inadequate forced motor cooling.

How to Clear & Reset Lenze Faults

  1. Keypad Reset: Press the STOP / RESET key directly on the plug-in keypad (Keypad XT or i500 keypad module) once the fault cause has been removed.
  2. Digital Input Terminal: Apply a 24VDC pulse to the digital input configured for error reset (e.g., parameter 0x2631:004 set to Reset Error on i500 series, or parameter C0410 on 8200/9300 series).
  3. EASY Starter / Engineer Software: Connect via USB diagnostic adapter or Ethernet, navigate to the diagnostic tab inside Lenze EASY Starter or Global Drive Control (GDC), and click “Reset Fault”.
  4. Mains Power Cycle: Disconnect the incoming 3-phase AC line supply, wait until all diagnostic LEDs turn completely off (minimum 5 minutes), and reclose the circuit breaker.
⚠️ High-Voltage Safety Warning: Intermediate circuit DC bus capacitors remain charged at lethal voltage levels after mains disconnection. Wait at least 5 to 10 minutes and verify with a calibrated digital multimeter across terminals (+UG) and (-UG) that the voltage is below 50VDC before inspecting internal components or touching power terminals.