| WARNING / AL001 Overcurrent |
Condition/Cause: Condition: Main circuit current is greater than 1.5 times the maximum instantaneous current of the servo drive. - The servo drive output is short-circuited.
- Motor wiring is in error.
- IGBT is abnormal.
- Parameter setting is in error.
- Control command setting is in error.
Remedy: - Check the connection between the motor and servo drive and make sure that the wire is not short-circuited. Do not expose the metal part of the wiring. Check if you have followed the wiring sequence for connecting the motor to the servo drive as described in this manual.
- If the temperature of the heat sink is abnormal, send your servo drive back to the distributor or contact Delta. Check if the set value of the parameter is much greater than the default. It is recommended to reset the parameter to the factory default setting and then modify the setting gradually.
- Check if the input control command changes greatly. If so, modify the rate of change in the command or enable the filter function.
- How to clear the alarm: DI.ARST
|
| WARNING / AL002 Overvoltage |
Condition/Cause: Condition: Main circuit voltage exceeds the rated value. - The input voltage of the main circuit is higher than the allowable rated value.
- Incorrect power input (incorrect power system).
- Malfunction of the servo drive hardware.
- Incorrect selection of the regenerative resistor or no connection to an external regenerative resistor.
Remedy: - Use a voltmeter to check if the input voltage of the main circuit is within the allowable rated value. If not, use the right voltage source or connect the regulator in series. Use a voltmeter to check if the power system complies with the specifications. If not, use the right voltage source or connect the transformer in series.
- If the alarm occurs when the input voltage of the main circuit is within the allowable rated value, send your servo drive back to the distributor or contact Delta.
- Check the connection for the regenerative resistor, re-calculate the value for the regenerative resistor, and correctly set the values of P1.052 and P1.053.
- How to clear the alarm: DI.ARST
|
| WARNING / AL003 Undervoltage |
Condition/Cause: Condition: Main circuit voltage is below the rated value or DC Bus voltage is below P4.024× √2. - The input voltage of the main circuit is lower than the allowable rated value.
- No voltage input to the main circuit.
- Incorrect power input (incorrect power system).
Remedy: - Check if the voltage wiring is correct and the wiring of input voltage for the main circuit is normal.
- Check the switch of the power supply and use a voltmeter to check the main circuit voltage.
- Use a voltmeter to check if the power system complies with the specifications. Check if using the right voltage source or connecting the transformer in series.
- How to clear the alarm: Set P2.066 [Bit 2] to clear AL003. If P2.066 [Bit 2] is set to 0, use DI.ARST to clear the alarm after the voltage is back in the normal range. If P2.066 [Bit 2] is set to 1, the alarm is automatically cleared once the voltage is back in the normal range.
|
| WARNING / AL004 Motor combination error |
Condition/Cause: Condition: An incorrect motor is used with the servo drive. - Motor combination error (the servo drive is connected to the wrong motor).
- The encoder connector is loose.
- The encoder is damaged.
Remedy: - Use the right motor.
- Check and re-install the encoder connector.
- If the encoder (motor) is not operating properly, replace the motor.
- How to clear the alarm: Cycle power on the servo drive.
|
| WARNING / AL005 Regeneration error |
Condition/Cause: Condition: An error occurs during regeneration. - Incorrect selection of the regenerative resistor or no connection to an external regenerative resistor.
- P1.053 (Regenerative resistor capacity) is not set to 0 when the regenerative resistor is not connected.
- Incorrect parameter settings for P1.052 and P1.053.
Remedy: - Check the connection for the regenerative resistor, re-calculate the value for the regenerative resistor, and correctly set the values of P1.052 and P1.053. If the issue persists, send your servo drive back to Delta.
- Set P1.053 to 0 if not using a regenerative resistor.
- Correctly set the regenerative resistor value (P1.052) and the regenerative resistor capacity (P1.053).
- How to clear the alarm: DI.ARST
|
| WARNING / AL006 Overload |
Condition/Cause: Condition: Overload of motor and servo drive. - The load is over the rated range and the servo drive is in a continuous overload condition.
- Improper parameter settings.
- Incorrect wiring of motor and encoder.
- Encoder malfunction.
Remedy: - Set P0.002 to 12 for monitoring if the average load rate [%] is continuously over 100%. If so, increase the motor capacity or reduce the load.
- Check if there is any mechanical vibration or the setting for acceleration or deceleration is too drastic.
- Check if the wiring of the UVW and the encoder cables are correct.
- Send the motor back to the distributor or contact Delta if the issue persists.
- How to clear the alarm: DI.ARST
|
| WARNING / AL007 Excessive deviation of Speed command |
Condition/Cause: Condition: Difference between the command speed and the feedback speed exceeds the allowable range set by P2.034. - A drastic change in the input Speed command.
- Improper setting of P2.034.
- Incorrect wiring of the UVW and the encoder cables.
Remedy: - Use the signal detector to check if the input analog voltage signal is normal. If not, adjust the rate of change for input signals or enable the filter function.
- Check if the value of P2.034 is set properly.
- Check if the wiring of the UVW and the encoder cables is correct.
- How to clear the alarm: DI.ARST
|
| WARNING / AL008 Abnormal pulse command |
Condition/Cause: Condition: The input frequency of the pulse command is over the allowable value for the hardware interface. - The pulse command frequency is higher than the rated input frequency.
Remedy: - Use the scope to check if the input frequency is higher than the rated input frequency and correctly set the input pulse frequency.
- How to clear the alarm: DI.ARST
|
| WARNING / AL009 Excessive deviation of Position command |
Condition/Cause: Condition: Difference between the command position and the feedback position exceeds the allowable range set by P2.035. - The maximum position deviation is set too low.
- Gain value is set too low.
- Torque limit or speed limit is set too low.
- Excessive external load.
- Improper setting for the E-Gear ratio.
- The power cables are loose.
- Speed limit is set too low.
Remedy: - Check the value of the maximum deviation (P2.035). If the value is too low, set a higher value.
- Check if the gain value is appropriate for the application.
- Check if internal speed and torque limits are set correctly.
- Check the external load. Reduce the external load or re-evaluate the motor capacity if necessary.
- Check if the settings for P1.044 and P1.045 are appropriate.
- Check if the power cables are loose.
- Check if the set value of P1.055 (Maximum speed limit) is too low.
- How to clear the alarm: DI.ARST
|
| WARNING / AL010 Voltage error during regeneration |
Condition/Cause: Condition: An error occurs during regeneration. - When the regenerative resistor is incorrectly selected or not connected, the regenerative voltage remains at 400V for a period of time.
- P1.053 (Regenerative resistor capacity) is not set to 0 when the regenerative resistor is not connected.
Remedy: - Check the connection for the regenerative resistor, re-calculate the value for it, and correctly set the values of P1.052 and P1.053. If the issue persists, send your servo drive back to Delta.
- Set P1.053 to 0 if not using a regenerative resistor.
- How to clear the alarm: DI.ARST
|
| WARNING / AL011 Encoder error |
Condition/Cause: Condition: The encoder produces abnormal pulses. - Encoder wiring is incorrect.
- Encoder connector is loose.
- Encoder wiring is poor.
- Connection to the encoder is cut off due to interference.
- Encoder is damaged.
Remedy: - Check if the wiring follows the instructions in the user manual. If not, connect the wiring correctly.
- Check the connection between CN2 and encoder connector. If the connector is loose, reconnect it to CN2.
- Check for the encoder cable and connector for any poor wiring or damaged wires. If so, replace the connector and cable.
- Check the communication error rate by setting P0.002 to -80. If this value continues to accumulate, it means there is interference. Check grounding, cable separation, and use of shielded cable.
- If you took all corrective actions but the issue persists, replace the motor.
- How to clear the alarm: Cycle power on the servo drive.
|
| WARNING / AL012 Calibration error |
Condition/Cause: Condition: The calibration value exceeds the allowable value during electronic calibration. - The analog input contact is not correctly returned to zero.
- The detection device is damaged.
Remedy: - Check if the voltage level at the analog input contact is the same as the ground potential.
- Reset the power supply. If the issue persists, send your servo drive back to the distributor or contact Delta.
- How to clear the alarm: Remove the connection cable for CN1 and then execute auto calibration.
|
| WARNING / AL013 Emergency stop |
Condition/Cause: Condition: The emergency stop button is pressed. - The emergency stop button is pressed.
Remedy: - Make sure the emergency stop button is off.
- How to clear the alarm: Set DI.EMGS to off to clear the alarm.
|
| WARNING / AL014 Negative limit error |
Condition/Cause: Condition: Negative limit switch is triggered. - Negative limit switch is triggered.
- Servo system is unstable.
Remedy: - Make sure the negative limit switch is off.
- Check the parameter setting or re-estimate the motor capacity.
- How to clear the alarm: The alarm is automatically cleared after the motor moves away from the limit.
|
| WARNING / AL015 Positive limit error |
Condition/Cause: Condition: Positive limit switch is triggered. - Positive limit switch is triggered.
- Servo system is unstable.
Remedy: - Make sure the positive limit switch is off.
- Check the parameter setting or re-estimate the motor capacity.
- How to clear the alarm: The alarm is automatically cleared after the motor moves away from the limit.
|
| WARNING / AL016 Abnormal IGBT temperature |
Condition/Cause: Condition: Temperature of IGBT is abnormal. - The load is over the rated range and the servo drive is in a continuous overload condition.
- The servo drive output is short-circuited.
Remedy: - Check for servo drive overload or motor overcurrent. If so, try increasing the motor's capacity or reducing the load.
- Check if the wiring of servo drive output is correct.
- How to clear the alarm: DI.ARST
|
| WARNING / AL017 EEPROM error |
Condition/Cause: Condition: Error occurs when DSP accesses EEPROM. - Parameter writing error or the value exceeds the allowable range.
- When power is supplied to the servo drive, the data in ROM is damaged or there is no data in ROM.
Remedy: - Press the SHIFT key to display the parameter code. If this alarm occurs when power is supplied, modify the value and cycle power. If the alarm occurs during normal operation, use DI.ARST to clear this alarm.
- If the panel displays "E100X" or "E0001", it is usually because the data in ROM is damaged. Send your servo drive back to the distributor or contact Delta.
- How to clear the alarm: If this alarm occurs when the drive is started, reset the parameters and then cycle the power. If the alarm occurs during operation, set DI.ARST to on.
|
| WARNING / AL018 Encoder output error |
Condition/Cause: Condition: The output pulse frequency of the encoder is higher than the maximum output frequency of the hardware. - The pulse resolution of the encoder is set too high.
- There is interference or cable damage causing communication error.
- Encoder error.
Remedy: - The settings of P1.076 and P1.046 should follow the requirements specified in the manual.
- Check the communication error rate by setting P0.002 to -80. If interference is present, check motor grounding, encoder signal cable separation, and use of a shielded cable.
- Check the fault record (P4.000 - P4.004) for other alarms and take corrective actions.
- If you do not need to use the OA/OB pulse, set P2.065 [Bit 13] to 1 to disable the detection function for this error.
- How to clear the alarm: DI.ARST or Contact the distributor.
|
| WARNING / AL020 Serial communication timeout |
Condition/Cause: Condition: RS-485 communication error. - Improper parameter setting for P3.004 (Modbus communication timeout).
- Servo drive has not received the communication command for a long time and has timed out.
Remedy: - Check and correctly set the value for the communication timeout parameter.
- Check if the communication cable is loose or broken and make sure it is correctly wired.
- How to clear the alarm: DI.ARST
|
| WARNING / AL022 RST leak phase |
Condition/Cause: Condition: RST power cable is loose or there is no power. (Warning by default).
Remedy: - Check if the RST power cable is loose or there is no power. Correctly connect the power to the servo drive. If the issue persists, send your servo drive back to the distributor or contact Delta.
- How to clear the alarm: DI.ARST
|
| WARNING / AL023 Early overload warning |
Condition/Cause: Condition: Early overload warning. - Servo drive is overloaded.
- The value of P1.056 (Motor output overload warning level) is set too low.
Remedy: - Check if your servo drive is overloaded and refer to the corrective actions for AL006 for troubleshooting.
- Check if the value of P1.056 is set too low. If so, set the value higher, or set the value greater than 100 to disable the warning function.
- How to clear the alarm: DI.ARST
|
| WARNING / AL024 Encoder initial magnetic field error |
Condition/Cause: Condition: The magnetic field of the encoder U, V, W signal is in error. - The initial magnetic field of the encoder is in error (Signal U, V, W of the encoder magnetic field is in error).
Remedy: - Check if the motor is properly grounded.
- Check the connection for the encoder signal cable is normal and separated from power or high-current cables.
- Use shielded cable for the encoder.
- For linear motors, check for wiring noise interference.
- Check the Hall sensor wiring and phase sequence.
- If the issue persists, send your servo motor back to the distributor or contact Delta.
- How to clear the alarm: Cycle power on the servo drive.
|
| WARNING / AL025 Encoder internal error |
Condition/Cause: Condition: Internal memory and counter of the encoder are in error. - Encoder internal error (internal memory and counter are in error).
- When power is applied, the motor rotates because of the inertia of the mechanism or other causes.
Remedy: - Check if the motor is properly grounded.
- Check the connection for the encoder signal cable is normal and separated from power or high-current cables.
- Use shielded cable for the encoder.
- Make sure the motor shaft does not move when power is turned on.
- How to clear the alarm: Cycle power on the servo drive.
|
| WARNING / AL026 Encoder unreliable internal data |
Condition/Cause: Condition: Internal data error occurs three consecutive times. - External interference.
- Malfunction of the encoder hardware.
Remedy: - If there is interference, check the following: motor grounding, encoder cable connection/separation, and use of shielded cable.
- Set P0.002 to -80 to monitor the communication error rate. If the value increases, re-check the interference items. If the value is 0, send your servo motor back to the distributor or contact Delta.
- How to clear the alarm: Cycle power on the servo drive.
|
| WARNING / AL027 Encoder internal reset error |
Condition/Cause: Condition: Encoder reset error.
Remedy: - Check if the encoder signal cable is firmly connected.
- Check if the power supply for the encoder is stable and use a shielded cable.
- Check if the operating temperature is over 95°C (203°F). Identify and resolve the cause for the high temperature.
- If the issue persists, send your servo motor back to the distributor or contact Delta.
- How to clear the alarm: Cycle power on the servo drive.
|
| WARNING / AL028 Battery voltage error or encoder internal error |
Condition/Cause: Condition: Battery voltage is higher than the specification (> 3.8V) or the encoder signal is in error. - Voltage level of the battery is too high.
- Encoder internal error.
Remedy: - Check if there is a charging circuit (e.g., Pin 1 of CN2 connected to BAT+ of the encoder). Avoid incorrect wiring.
- Check if the battery is correctly installed (voltage > 3.8V).
- Check if the motor is properly grounded.
- Check the encoder signal cable connection and ensure it is separated from power/high-current cables.
- Use shielded cable for the encoder.
- If the issue persists, send your servo drive and motor back.
- How to clear the alarm: Cycle power on the servo drive.
|
| WARNING / AL029 Gray code error |
Condition/Cause: Condition: Absolute position error.
Remedy: - Cycle power on the servo drive to operate the motor. Then, check if the alarm occurs again. If the issue persists, replace the encoder.
- How to clear the alarm: Cycle power on the servo drive.
|
| WARNING / AL02A Number of revolutions of the encoder is in error |
Condition/Cause: Condition: The number of revolutions of the encoder is in error. - The internal signal of the encoder is abnormal causing error in the number of revolutions.
Remedy: - Send your servo motor back to the distributor or contact Delta.
- How to clear the alarm: N/A
|
| WARNING / AL02B Motor data error |
Condition/Cause: Condition: Accessing the internal data of the motor is in error. - Accessing the internal data of the motor is in error.
Remedy: - Send your servo motor back to Delta.
- How to clear the alarm: N/A
|
| WARNING / AL030 Motor collision error |
Condition/Cause: Condition: When the motor hits the device, the torque reaches the value set by P1.057 and the duration exceeds the time set by P1.058. - The protection function of motor hard stop (P1.057) is enabled.
- The value set by P1.057 is too low and the time set by P1.058 is too short.
Remedy: - Check if P1.057 is enabled. If so, set P1.057 to 0.
- Set P1.057 according to the actual torque.
- Cycle power on the servo drive to operate the motor. If the alarm occurs again, replace the encoder.
- How to clear the alarm: DI.ARST
|
| WARNING / AL031 Motor power cable wiring error / disconnection |
Condition/Cause: Condition: Incorrect wiring or disconnection of the motor power cable (U, V, W) and ground wire (GND). - Incorrect wiring or disconnection of the power cable (U, V, W) and ground wire (GND). The detection for this is disabled by default.
Remedy: - Check if the motor power cable (U, V, W) and ground wire (GND) are firmly connected. Follow the instructions in the user manual for correct wiring and proper grounding.
- How to clear the alarm: Cycle power on the servo drive.
|
| WARNING / AL032 Abnormal encoder vibration |
Condition/Cause: Condition: Abnormal vibration occurred in the encoder. - The internal signal or mechanical part of the encoder is abnormal, so the encoder returns an error signal.
Remedy: - Check if the motor vibration range is within 2.5 G. If the vibration is within the range, send your servo motor back to the distributor or contact Delta.
- How to clear the alarm: DI.ARST or cycle power on the servo drive.
|
| WARNING / AL033 26-pin connector for the converter box is disconnected or motor is abnormal |
Condition/Cause: Condition: 26-pin connector for the converter box is disconnected or motor is abnormal. - The 26-pin connector for the converter box is wired incorrectly or disconnected.
- The motor is abnormal.
Remedy: - Check the status of the converter box and check the specified pins for disconnection depending on the mode (Switch Mode or Drive Mode).
- If the servo system is not connected to the converter box, but AL033 still occurs, send the servo motor back to Delta.
- How to clear the alarm: After connecting the disconnected pins, cycle power on the servo drive.
|
| WARNING / AL034 Encoder internal communication error |
Condition/Cause: Condition: Internal communication error for the absolute or other types of encoder. - Encoder internal communication error.
Remedy: - Check if the battery wiring is correct or loose. If it is loose, wire it again and cycle power on the system.
- Check if the battery voltage is within the normal range.
- If an internal communication error for the absolute encoder occurs, replace the motor.
- How to clear the alarm: Cycle power on the servo drive.
|
| WARNING / AL035 Encoder temperature exceeds the protective range |
Condition/Cause: Condition: Encoder temperature is over the upper limit of 100°C (212°F). - Encoder temperature is over 100°C.
Remedy: - Set P0.002 to -124 to read the temperature and check if it is below 100°C.
- If the encoder temperature is higher than 100°C, improve the heat dissipation to lower the temperature.
- If the temperature difference between the encoder and motor is over 30°C (86°F), send the servo motor back to Delta.
- How to clear the alarm: After the temperature detector shows a temperature below 100°C, cycle power on the servo drive.
|
| WARNING / AL036 Encoder alarm status error |
Condition/Cause: Condition: Abnormal state occurred in the encoder. - The encoder sends out an alarm signal, but the alarm status of the encoder read by the servo drive shows no error.
Remedy: - Check if the motor is properly grounded.
- Check if the connection for the encoder signal cable is normal and separated from power/high-current cables.
- Use shielded cable for the encoder.
- Check the motor speed and make sure it is within the rated range.
- If the issue persists, send your servo motor back to the distributor or contact Delta.
- How to clear the alarm: DI.ARST or cycle power on the servo drive.
|
| WARNING / AL040 Excessive position error of full-closed loop control |
Condition/Cause: Condition: Excessive position error of full-closed loop control. - The setting value of P1.073 is too low.
- The connector may be loose or there is a problem with the mechanical connection.
- The number of A/B pulses in a full-closed loop is not an integer, causing position error to accumulate.
Remedy: - Check the value for P1.073. If the value is too low, set a higher value.
- Make sure the connector is firmly connected and there is no problem with the mechanical connection.
- Check if the value of P1.085 is set properly to avoid triggering AL040.
- How to clear the alarm: DI.ARST
|
| WARNING / AL041 CN5 is disconnected |
Condition/Cause: Condition: The communication of CN5 is disconnected. - The communication of CN5 is disconnected.
Remedy: - Check the communication circuit of CN5.
- When CN5 is not in use, check if both P1.074.X and PM.003.U are set to 0.
- How to clear the alarm: DI.ARST
|
| WARNING / AL042 Analog voltage input for Speed command is too high |
Condition/Cause: Condition: Analog voltage input for the Speed command is higher than the level specified by P1.083. - Analog voltage input for the Speed command is higher than the level specified by P1.083.
Remedy: - Check and make sure the voltage source for the analog Speed command is correct. Check the value of P1.083, and if this function is not required, set it to 0.
- How to clear the alarm: DI.ARST
|
| WARNING / AL044 Servo function operational warning |
Condition/Cause: Condition: Too many motor control functions on the servo drive are enabled. - Servo function operational alarm.
Remedy: - If using a filter, see if it is necessary.
- Disable unnecessary filters, such as the low-pass filter, moving filter, vibration suppression, etc.
- To disable this alarm, set P2.066 [Bit 4] to 1 and cycle power on the servo drive.
- How to clear the alarm: Disable unnecessary functions or disable the alarm via P2.066 [Bit 4].
|
| WARNING / AL045 E-Gear ratio value error |
Condition/Cause: Condition: When the value of the E-Gear ratio exceeds the range (1/4 - 262144), this alarm occurs once power is cycled. - E-Gear ratio value is found to be in error after the servo drive is powered on.
Remedy: - Check if the value of the E-Gear ratio is within the allowable range. If not, correct the value and then cycle power on the servo drive.
- How to clear the alarm: Cycle power on the servo drive after the value is corrected.
|
| WARNING / AL048 Encoder output error |
Condition/Cause: Condition: The output pulse frequency of the encoder is higher than the maximum output frequency of the hardware. - The pulse resolution of the encoder is set too high.
- There is interference or cable damage causing communication error.
- Encoder error.
Remedy: - Check that the settings of P1.076 and P1.046 follow the specified requirements.
- Check for interference by checking the communication error rate (P0.002 to -80). This includes checking motor grounding, cable separation, and using a shielded cable.
- Check the fault record for other related alarms (AL011, AL024, etc.)
- If the OA/OB pulse is not needed, disable the detection function by setting P2.065 [Bit 13] to 1.
- How to clear the alarm: 1. DI.ARST 2. Contact the distributor.
|
| WARNING / AL050 Motor parameter identification is complete |
Condition/Cause: Condition: The Motor Parameter Identification Wizard was used and the identification is complete. - The Motor Parameter Identification Wizard function was successfully completed.
Remedy: - Cycle power on the servo drive.
- How to clear the alarm: Cycle power on the servo drive.
|
| WARNING / AL051 Motor parameter automatic identification error |
Condition/Cause: Condition: An error occurs when the Motor Parameter Identification Wizard function is used. - The friction is too large causing the motor to be unable to run.
- Input values of the resolution and magnetic pole pitch are too large.
Remedy: - Check if PM.003, PM.004, and PM.045 are set correctly.
- Make sure the motor can operate properly.
- Check if the friction between the motor and mechanical part is too large.
- Check if the feedback signal is abnormal.
- Check for interference causing pulse leakage.
- How to clear the alarm: DI.ARST
|
| WARNING / AL052 Initial magnetic field detection error |
Condition/Cause: Condition: The initial magnetic field detection is not complete because the motor moves too far, the detection times out, or the motor is unable to operate correctly. - When you choose not to install the Hall sensor, the servo automatically detects the magnetic field when Servo On. This alarm is displayed when the servo cannot detect the magnetic field.
Remedy: - Make sure that the source of the feedback signal is correct.
- Check if the feedback signal is abnormal using the software scope.
- Make sure the motor and mechanical part can operate properly (check for brakes, uneven running, etc.).
- Check if the friction is too large.
- Check for interference by ensuring proper grounding and using shielded cables.
- How to clear the alarm: DI.ARST
|
| WARNING / AL053 Motor parameters are not confirmed |
Condition/Cause: Condition: If the Motor Parameter Identification Wizard function has not been executed or the identification failed, this alarm is triggered when the servo is on. - The Motor Parameter Identification Wizard function has not been executed for the third-party motor or the identification process failed.
Remedy: - Execute or re-execute the Motor Parameter Identification Wizard function.
- How to clear the alarm: Switch the servo to the Servo Off state to clear this alarm.
|
| WARNING / AL054 Parameter is out of range due to switching of motor types |
Condition/Cause: Condition: Set value of PM.004 exceeds the allowable range. - Set value of PM.004 exceeds the allowable range.
Remedy: - Check if the set values of PM.000, PM.003, PM.004, and PM.013 match the specifications of the connected motor.
- If the issue persists, set P2.008 to 18 to reset the PM parameters.
- How to clear the alarm: Cycle power on the servo drive.
|
| WARNING / AL055 Motor magnetic field error |
Condition/Cause: Condition: The difference between the monitored magnetic field from the Hall sensor and the calculated magnetic field is too large. - When PM.009.Y is set to 1, the servo detects the current magnetic field position and compares it with the Hall sensor's position. If the error is too large, this alarm is triggered.
Remedy: - Check if the Hall sensor is abnormal or if there is interference.
- Check if the feedback signal is abnormal using the software scope.
- Check if the feedback signal has interference causing pulse leakage.
- For square-wave digital signals, check motor speed and filter settings.
- How to clear the alarm: Cycle power on the servo drive.
|
| WARNING / AL056 Excessive motor speed |
Condition/Cause: Condition: When the filtered motor speed exceeds the setting of P1.111, the servo drive switches to Servo Off. - This alarm reminds the user that the motor speed has reached the upper limit of the current setting (P1.111).
Remedy: - Check the reason for the high motor speed (e.g., P1.111 set too small, incorrect bandwidth).
- Evaluate the motor speed and mechanical parts. If allowable, increase the speed and the set value of P1.111.
- How to clear the alarm: DI.ARST
|
| WARNING / AL057 Feedback pulse is lost |
Condition/Cause: Condition: When P2.081 is set to 1, pulse leakage exceeds the set value of P2.082. - Pulse leakage occurs during motor operation.
- The pulse signal is interfered by noise.
Remedy: - Check if pulse leakage has occurred due to noise interference.
- If there is interference, check motor grounding and use shielded cable for the feedback signal cable.
- If the encoder feedback type is a square-wave digital signal, check motor speed against hardware limits and consider using filter functions.
- Set the maximum speed limit of the motor with P1.055.
- How to clear the alarm: Cycle power on the servo drive.
|
| WARNING / AL058 Excessive position deviation after initial magnetic field detection is complete |
Condition/Cause: Condition: After initial magnetic field detection, the servo system fails to reduce the existing position error. - The controller issues commands during initial magnetic field detection before the servo system is fully settled.
Remedy: - Check if the controller issues a command immediately on power-on. Increase the delay time for the controller.
- If the controller time sequence cannot be modified, set P2.088 [Bit 4] to 1 to prohibit the servo from receiving controller commands during the initial magnetic field detection.
- How to clear the alarm: DI.ARST
|
| WARNING / AL05B Motor type setting does not match |
Condition/Cause: Condition: Incorrect setting of PM.000. - A Delta motor is connected to CN2, but PM.000 is not set to 0.
- A Delta magnetic encoder is used, but PM.000 or PM.003 is set incorrectly.
Remedy: - Check the setting of PM.000 and ensure the motor type used complies with the setting.
- If a Delta motor with magnetic encoder is used, set PM.000 to 0 and PM.003 to 0x1XX2.
- How to clear the alarm: Cycle power on the servo drive.
|
| WARNING / AL05C Motor position feedback error |
Condition/Cause: Condition: Sudden jumps occur to the motor position feedback. - Encoder feedback is abnormal or the encoder is damaged.
- Encoder feedback is interfered.
Remedy: - Use the software scope to monitor the feedback position for discontinuous jumps.
- Check if the feedback signal is interfered.
- If the source is CN2, check if the communication error rate is increased due to interference.
- How to clear the alarm: Cycle power on the servo drive.
|
| WARNING / AL05D Detection error for offset between absolute encoder zero point and motor magnetic field zero point |
Condition/Cause: Condition: Error occurred when the Wizard detected the offset for a third-party absolute motor. - The difference between the actual magnetic field angle of the motor and the set value is too big.
Remedy: - Check if parameters PM.003, PM.004, PM.028, and PM.045 are set correctly.
- Make sure you can manually operate the motor.
- Check if friction is too large.
- Check if there is interference (check grounding and use shielded cable).
- How to clear the alarm: DI.ARST
|
| WARNING / AL05E Position signal converter box communication failure |
Condition/Cause: Condition: Communication error occurs when the Delta position signal converter box is connected to the CN2 connector. - A communication error occurred with the position signal converter box.
- A communication error occurred during the Motor Parameter Identification Wizard setting process.
Remedy: - Check the wiring of the position signal converter box and the encoder cable for damage.
- Check the communication error rate for interference. Ensure proper grounding and use of shielded cables.
- If the issue persists, replace the motor.
- How to clear the alarm: Cycle power on the servo drive.
|
| WARNING / AL060 Absolute position is lost |
Condition/Cause: Condition: Losing the recorded number of revolutions because of low battery voltage or loss of power. - Voltage level of the battery is too low.
- The battery is replaced when the main power of the servo drive is off.
- The battery is not installed when the absolute function is enabled.
- Poor connection or disconnection of the battery power circuit.
Remedy: - Check if the battery voltage is below 2.9V. Re-establish the absolute origin coordinates after replacing the battery.
- Do not replace or remove the battery when the servo drive's main power is off.
- Follow instructions to install the battery and check wiring.
- How to clear the alarm: Connect or reconnect the wiring so that the battery power is supplied to the encoder and then re-establish the absolute origin coordinates.
|
| WARNING / AL06A Absolute position is lost |
Condition/Cause: Condition: Loss of absolute position due to coordinates not being established, or an error occurring after they were established. - Coordinates not established: Servo used for the first time; battery drained; bus communication servo used after first use or E-Gear ratio modification.
- Error occurred: Encoder cable damaged; momentary battery power failure; absolute motor error; battery box J1/J2 connected reversely; battery voltage < 2.9V.
Remedy: - Check if absolute origin coordinates are established.
- Avoid replacing the battery when the servo drive is powered off.
- Re-establish the absolute origin coordinates.
- Replace the encoder cable if damaged.
- Check for loose wiring.
- Replace the servo motor if faulty.
- Ensure battery box J1 and J2 are connected correctly.
- How to clear the alarm: This alarm is automatically cleared after you establish the absolute origin coordinates.
|
| WARNING / AL06B The error between the servo drive internal coordinate and the encoder coordinate is too large |
Condition/Cause: Condition: When the absolute motor is powered by the battery, the number of motor rotations exceeds half the number of revolutions of the resolution. - The error between the servo drive internal coordinate and the encoder coordinate is too large. This can be caused by mechanical parts not being properly fastened when the machine is being transported, causing rotation of the motor.
Remedy: - Re-establish the absolute origin coordinates.
- How to clear the alarm: Re-establish the absolute origin coordinates.
|
| WARNING / AL06E Encoder type is unidentifiable |
Condition/Cause: Condition: The servo drive cannot identify the encoder type. - The servo drive cannot identify the encoder type.
Remedy: - Replace the motor immediately.
- How to clear the alarm: Replace the motor immediately.
|
| WARNING / AL06F The absolute position is not established |
Condition/Cause: Condition: The establishment of the absolute position has timed out. - The process for establishing the absolute position of the servo drive is in error.
Remedy: - If the issue persists after you cycle power on the servo drive and re-establish the absolute origin coordinates, contact your local distributor or technician.
- How to clear the alarm: Cycle power on the servo drive and re-establish the absolute origin coordinates.
|
| WARNING / AL070 Encoder did not complete the read / write procedure |
Condition/Cause: Condition: Reading and writing commands are not complete. - Reading and writing commands are not complete.
Remedy: - Check if the wiring is correct and firmly connected. If not, correctly connect the wiring again. Contact Delta if this error persists.
- How to clear the alarm: Cycle power on the servo drive.
|
| WARNING / AL071 Number of revolutions of the encoder is in error |
Condition/Cause: Condition: The number of revolutions of the encoder is in error. - The internal signal of the encoder is abnormal causing error in the number of revolutions of the encoder.
Remedy: - If you executed DI.ARST but the issue persists, send your servo motor back to the distributor or contact Delta.
- How to clear the alarm: DI.ARST
|
| WARNING / AL072 Encoder overspeed |
Condition/Cause: Condition: Encoder speed is over 8,800 rpm (on servo drive power) or 10,000 rpm (on battery power). - Encoder speed exceeds limits.
- Voltage level of the battery is too low.
Remedy: - Check if the motor is properly grounded.
- Check the connection for the encoder signal cable is normal and separated from interference.
- Use shielded cable for the encoder.
- Check the motor speed and make sure it is within the rated range.
- Measure the battery voltage to see if it is below 3.1V.
- Check if the battery wiring has poor contact.
- How to clear the alarm: Cycle power on the servo drive.
|
| WARNING / AL073 Encoder memory error |
Condition/Cause: Condition: An error occurs when the encoder is reading data from or writing data to EEPROM. - An error occurs when the encoder is reading data from or writing data to EEPROM.
Remedy: - Check if the motor is properly grounded.
- Check for proper cable connection and separation from interference.
- Use shielded cable for the encoder.
- Check the motor speed is within the rated range.
- If the issue persists, send your servo motor back to the distributor or contact Delta.
- How to clear the alarm: Cycle power on the servo drive.
|
| WARNING / AL074 Encoder single-turn absolute position is in error |
Condition/Cause: Condition: The single-turn position in the encoder is in error. - The single-turn position in the encoder is in error.
Remedy: - Check if the motor is properly grounded.
- Check for proper cable connection and separation from interference.
- Use shielded cable for the encoder.
- Check the motor speed is within the rated range.
- If the issue persists, send your servo motor back to the distributor or contact Delta.
- How to clear the alarm: Cycle power on the servo drive.
|
| WARNING / AL075 Encoder absolute number of revolutions is in error |
Condition/Cause: Condition: The absolute number of revolutions in the encoder is in error. - The absolute number of revolutions in the encoder is in error.
Remedy: - Check motor grounding, cable connection, use of shielded cable, and motor speed.
- If the issue persists, send your servo motor back.
- How to clear the alarm: Cycle power on the servo drive.
|
| WARNING / AL077 Encoder internal error |
Condition/Cause: Condition: Encoder internal error (internal computing error). - Encoder internal computing error.
Remedy: - Check motor grounding, cable connection, use of shielded cable, and motor speed.
- If the issue persists, send your servo motor back.
- How to clear the alarm: Cycle power on the servo drive.
|
| WARNING / AL079 Encoder parameter setting incomplete |
Condition/Cause: Condition: The servo drive is not cycled after an encoder parameter is written. - The parameter value is not updated because the power was not cycled.
Remedy: - Check if the encoder parameter is written. If so, cycle power to activate the parameter.
- How to clear the alarm: Cycle power on the servo drive.
|
| WARNING / AL07A Encoder Z phase position is lost |
Condition/Cause: Condition: Encoder Z phase position is in error. - Encoder Z phase position is in error.
Remedy: - Send your servo motor back to the distributor or contact Delta.
- How to clear the alarm: N/A
|
| WARNING / AL07B Encoder memory is busy |
Condition/Cause: Condition: The encoder memory is busy. - The encoder memory is busy.
Remedy: - Check motor grounding, cable connection, use of shielded cable, and motor speed.
- If the issue persists, send your servo motor back.
- How to clear the alarm: Cycle power on the servo drive.
|
| WARNING / AL07C Command to clear the absolute position is issued when the motor speed is over 200 rpm |
Condition/Cause: Condition: The command to clear the absolute position is issued when motor speed exceeds 200 rpm. - A command to clear the absolute position was issued while the motor speed was over 200 rpm.
Remedy: - Check if a command to clear the absolute position was issued while the motor speed is over 200 rpm. If so, follow the procedure for clearing the absolute position to clear this alarm.
- Do not issue a command to clear the absolute position when the motor speed is over 200 rpm.
- How to clear the alarm: Cycle power on the servo drive.
|
| WARNING / AL07D Motor stops operating when servo drive power is cycled before AL07C is cleared |
Condition/Cause: Condition: AL07C occurs and is not cleared before power is cycled. - Power is cycled on the servo drive before AL07C is cleared, causing the motor to stop operating.
Remedy: - Use DI.ARST to clear the alarm. Once this alarm is cleared, AL07C occurs. Follow the checking method and corrective action to clear AL07C.
- How to clear the alarm: Cycle power on the servo drive.
|
| WARNING / AL07E Error occurs when the encoder clears the procedure |
Condition/Cause: Condition: The number of retry attempts for the encoder to clear the procedure exceeds 11 times. - The number of retry attempts exceeds 11 times.
Remedy: - If the issue persists, set P0.002 to -80 to check the communication quality of the encoder. If the communication is normal, use DI.ARST to clear this alarm.
- How to clear the alarm: Cycle power on the servo drive.
|
| WARNING / AL07F Encoder version error |
Condition/Cause: Condition: The encoder version read by the servo drive is in error. - The encoder version read by the servo drive is in error.
Remedy: - Replace the motor immediately.
- How to clear the alarm: Replace the motor immediately.
|
| WARNING / AL083 Servo drive outputs excessive current |
Condition/Cause: Condition: Servo drive outputs current that is over the allowable level specified by the firmware. - UVW cable is short-circuited.
- Motor wiring is in error.
- The analog signal GND for the servo drive is interfered.
Remedy: - Check the connection between the motor power cable and its connector. If wire is exposed or torn, replace the power cable.
- Make sure the UVW wiring sequence is correct.
- Check if the analog signal GND is mistakenly connected to another ground signal.
- How to clear the alarm: DI.ARST
|
| WARNING / AL085 Regeneration setting error |
Condition/Cause: Condition: Regeneration control error. - Regenerative resistor is not operating, but the regenerative voltage remains at 400V for a period of time.
Remedy: - Check the connection for the regenerative resistor, re-calculate the value, and correctly set the values of P1.052 and P1.053.
- If the issue persists, send your servo drive back to Delta.
- How to clear the alarm: DI.ARST
|
| WARNING / AL086 Regenerative resistor overload |
Condition/Cause: Condition: Excessive energy in the capacitor of the servo drive is released to the regenerative resistor causing overload. - Incorrect selection of the regenerative resistor or no connection.
- Incorrect parameter settings for P1.052 and P1.053.
- Other energy (such as interference) is input to the servo drive or input voltage is too high.
- Malfunction of the servo drive hardware.
Remedy: - Check the connection for the regenerative resistor and correctly set the values of P1.052 and P1.053.
- Reassess whether the regenerative energy exceeds the value of P1.053. If so, replace the resistor with a higher capacity one.
- Use a voltmeter to measure if the input voltage is within the allowable range.
- Measure the voltage between P3 and terminals. If it does not match the displayed DC Bus voltage, the servo drive may be malfunctioning.
- How to clear the alarm: DI.ARST
|
| WARNING / AL088 Servo function operational alarm |
Condition/Cause: Condition: Too many motor control functions on the servo drive are enabled. - Servo function operational alarm.
Remedy: - If using a filter, see if using this filter is necessary.
- Disable the filter if it is not required, such as the low-pass filter, moving filter, etc.
- How to clear the alarm: Disable unnecessary functions.
|
| WARNING / AL089 Current detection interference |
Condition/Cause: Condition: Current detection interference. - Current detection in the servo drive is affected by an external interference source.
Remedy: - Check the environment around the servo drive for any interference source.
- Remove the interference source or move the servo drive away from it.
- Set P2.112 [Bit 1] to 0 to disable AL089.
- If the issue persists, send your servo drive back to the distributor or contact Delta.
- How to clear the alarm: Remove interference, disable alarm, or contact distributor.
|
| WARNING / AL08A Auto-tuning function - command error |
Condition/Cause: Condition: No command is issued within 15 seconds after the servo drive starts the auto-tuning procedure. - When the command source is the controller, neither the controller nor the position register issued the command.
- When the command source is the servo drive, Position 1 and Position 2 specify the same position.
- The signal cable is not connected or incorrectly connected.
Remedy: - Make sure a command is being issued.
- Make sure the wiring between the controller and servo drive is correct.
- How to clear the alarm: DI.ARST
|
| WARNING / AL08B Auto-tuning function - pause time is too short |
Condition/Cause: Condition: The pause time is too short when the command source is the controller in the auto-tuning procedure. - Pause time in the cycle is too short.
Remedy: - For a reciprocating motion, pausing is required on the return, which has to be longer than 1 second.
- For rotation in a single direction, pause time is required when the motor rotates a certain number of cycles (> 2 cycles).
- How to clear the alarm: DI.ARST
|
| WARNING / AL08C Auto-tuning function - inertia estimation error |
Condition/Cause: Condition: Inertia estimation error occurs when the servo drive starts the auto-tuning procedure. - Acceleration or deceleration time is too long.
- Rotation speed is too slow.
- Load inertia of the machine is too large.
- Inertia variation of the machine is too drastic.
Remedy: - The time for the motor to accelerate/decelerate from 0 to 3,000 rpm must be within 1.5 seconds.
- The lowest speed should be no less than 200 rpm (suggested 500 rpm or higher).
- The load inertia should be less than 50 times the motor inertia.
- Avoid applications that require drastic variation in the inertia.
- How to clear the alarm: DI.ARST
|
| WARNING / AL095 Regenerative resistor is disconnected |
Condition/Cause: Condition: The value of P1.053 is not 0 and the external regenerative resistor or brake is not connected (Only for servo drives of 5.5 kW or above). - P1.053 (Regenerative resistor capacity) is not 0 and the external regenerative resistor or brake is not connected.
Remedy: - If the regenerative brake is required, connect the external regenerative resistor and ensure P1.053 is correct.
- If not using the regenerative brake, set P1.053 to 0.
- If the issue persists, send your servo drive back to the distributor or contact Delta.
- How to clear the alarm: DI.ARST
|
| WARNING / AL099 DSP firmware error |
Condition/Cause: Condition: EEPROM is not reset after DSP firmware is updated. - EEPROM is not reset after DSP firmware is updated.
Remedy: - Check if the firmware is updated. Set P2.008 to 30 first and then set it to 28. Next, cycle power. Contact Delta if this error persists.
- How to clear the alarm: Set P2.008 to 30 and then 28. Cycle power on the servo drive.
|
| WARNING / AL09C Parameter reset failed |
Condition/Cause: Condition: The parameter reset process is not complete. - An error occurred during the parameter reset process, so the reset procedure could not be completed.
Remedy: - Check if the power is cut off during the reset process. Check the power wiring and switch.
- How to clear the alarm: Set P2.008 to 30 and then 28. Cycle power on the servo drive.
|
| WARNING / AL0A6 Absolute position coordinates of the servo drive and motor do not match |
Condition/Cause: Condition: Operating a servo drive with a motor that has absolute origin coordinates established with a different drive. - Replace the servo drive or servo motor.
Remedy: - Re-establish the absolute origin coordinates.
- How to clear the alarm: Re-establish the absolute origin coordinates.
|
| WARNING / AL111 Buffer overflow occurs when SDO is received |
Condition/Cause: Condition: SDO Rx Buffer overflows (the servo drive receives more than two SDOs within 1 ms). - The servo drive receives more than two SDOs within 1 ms.
Remedy: - Check if the servo drive (master) receives or sends more than one SDO within 1 ms.
- How to clear the alarm: NMT: reset node, 0x6040 fault reset, or DI.ARST.
|
| WARNING / AL112 Buffer overflow occurs when PDO is received |
Condition/Cause: Condition: PDO Rx Buffer overflows (the servo drive receives more than two PDOs of the same COB-ID within 1 ms). - The servo drive receives more than two PDOs of the same COB-ID within 1 ms.
Remedy: - Check if the servo drive (master) receives or sends more than one PDO of the same COB-ID within 1 ms.
- How to clear the alarm: NMT: reset node, 0x6040 fault reset, or DI.ARST.
|
| WARNING / AL113 TxPDO transmission failed |
Condition/Cause: Condition: PDO packet cannot be successfully sent. - PDO packet cannot be successfully sent.
Remedy: - Check if the communication circuit of the servo drive works properly.
- How to clear the alarm: NMT: reset node, 0x6040 fault reset, or DI.ARST.
|
| WARNING / AL121 Object's index does not exist when PDO is accessed |
Condition/Cause: Condition: The specified object's index number in the PDO from the controller is incorrect. - The specified object's index number is incorrect.
Remedy: - Check if the object's index number for PDO mapping of the controller is correct.
- If the index number is correct, the object is not supported by the servo drive. Check if it is necessary or can be substituted.
- How to clear the alarm: NMT: reset node, 0x6040 fault reset, or DI.ARST.
|
| WARNING / AL122 Object's sub-index does not exist when PDO is accessed |
Condition/Cause: Condition: The specified object's sub-index number in the PDO from the controller is incorrect. - The specified object's sub-index number is incorrect.
Remedy: - Check if the object's sub-index number for PDO mapping of the controller is correct.
- If the sub-index number is correct, the object is not supported. Check if it is necessary or can be substituted.
- How to clear the alarm: NMT: reset node, 0x6040 fault reset, or DI.ARST.
|
| WARNING / AL123 Data length error occurs when PDO is accessed |
Condition/Cause: Condition: Data length in the message does not match the length of the specified object. - Data length in the message does not match the specified object's length.
Remedy: - Check if the data length of PDO mapping entry is changed when the servo drive receives or sends PDO.
- How to clear the alarm: NMT: reset node, 0x6040 fault reset, or DI.ARST.
|
| WARNING / AL131 EEPROM CRC calculation error |
Condition/Cause: Condition: The data in ROM is damaged. All objects are automatically restored to default values. - The data in ROM is damaged. Usually caused by an error in DSP.
Remedy: - Check if the specified object causes a CRC calculation error in EEPROM when the servo drive receives or sends PDO.
- How to clear the alarm: NMT: reset node, 0x6040 fault reset, or DI.ARST.
|
| WARNING / AL132 Parameter is write-protected |
Condition/Cause: Condition: When data is written to the parameter using bus communication, the parameter is currently write-protected. - The parameter is currently write-protected.
Remedy: - Refer to the corresponding parameter description to write data to the parameter.
- How to clear the alarm: NMT: reset node, 0x6040 fault reset, or DI.ARST.
|
| WARNING / AL170 Bus communication timeout |
Condition/Cause: Condition: The servo drive does not receive any PDO data within the set communication cycle time.
Remedy: - Check if the communication is normal.
- Check if the wiring is correctly connected.
- How to clear the alarm: NMT: reset node, 0x6040 fault reset, or DI.ARST.
|
| WARNING / AL185 Bus hardware error |
Condition/Cause: Condition: Bus communication is cut off. - Abnormal communication hardware.
Remedy: - Check if the communication cable is intact and firmly connected.
- Check the communication quality. It is suggested that you use common grounding and shielded cable.
- For communication type models, check if the value of monitoring variable 120 increases continuously.
- How to clear the alarm: NMT: reset node, 0x6040 fault reset, or DI.ARST.
|
| WARNING / AL21B Second development platform - memory stack is out of range |
Condition/Cause: Condition: When a stack control command is used, the memory address is out of range. - Incorrect use of the command of the second development platform.
Remedy: - Refer to the command descriptions for the second development platform to ensure the correct use of the commands. If you took the corrective action but the issue persists, contact the local distributor or technician.
- How to clear the alarm: DI.ARST
|
| WARNING / AL21D Second development platform - a divisor in an expression is zero in the program |
Condition/Cause: Condition: A divisor in an expression is zero in the program. - Programming error of the second development platform.
Remedy: - Check if the programs of the second development platform contain expressions with zero as the divisor. If the issue persists, contact the local distributor or technician.
- How to clear the alarm: DI.ARST
|
| WARNING / AL221 Second development platform - a non-existing mode is used |
Condition/Cause: Condition: The MODE command is used to execute a non-existing mode number. - Incorrect use of the command of the second development platform.
Remedy: - Refer to the command descriptions for the second development platform to ensure the correct use of the commands. If the issue persists, contact the local distributor or technician.
- How to clear the alarm: DI.ARST
|
| WARNING / AL223 Second development platform - some commands are not allowed to be used when the servo is in the ERROR or FAULT state |
Condition/Cause: Condition: The servo is in the ERROR or FAULT state when a specific command is used. - Incorrect use of the command of the second development platform.
Remedy: - Refer to the command descriptions for the second development platform to ensure if the servo can be in the ERROR or FAULT state when the command is used.
- If you took the corrective action but the issue persists, contact the local distributor or technician.
- How to clear the alarm: DI.ARST
|
| WARNING / AL22D Absolute positioning cannot be executed when E-Cam is engaged |
Condition/Cause: Condition: Absolute positioning is executed when E-Cam is engaged. - Absolute positioning is executed when E-Cam is engaged.
Remedy: - Check if E-Cam is engaged when the servo is executing absolute positioning.
- How to clear the alarm: DI.ARST
|
| WARNING / AL231 Monitoring item of Type [8] PR is out of range |
Condition/Cause: Condition: The code of the monitoring item for Type [8] PR command, Sys_Var, is out of range. - The monitoring item is out of range.
Remedy: - Write parameter using PR procedure: when the code of the monitoring item exceeds the range, check the code range for the monitoring item.
- How to clear the alarm: DI.ARST
|
| WARNING / AL235 Position counter overflow warning |
Condition/Cause: Condition: A positioning command is executed after the overflow of the position command counter. - Overflow of the position command counter.
- Absolute system specific: Position feedback register overflows; absolute origin coordinates not established after P1.001.Z or E-Gear ratio change; established absolute origin coordinates procedure is incomplete.
Remedy: - Incremental system: Use the scope to check if the feedback position has overflowed and then execute the homing procedure. After using DI.ARST to clear the alarm, perform homing procedure.
- Absolute system: Check for the overflow conditions. Establish the absolute origin coordinates.
- How to clear the alarm: Incremental system: perform homing. Absolute system: establish absolute origin coordinates.
|
| WARNING / AL237 Indexing coordinate is undefined |
Condition/Cause: Condition: The starting point of the indexing coordinate is not defined before you operate the indexing function. - The servo drive cannot identify the coordinate system because the starting point is not defined.
Remedy: - Check if the indexing coordinate is undefined: perform the homing procedure before using the indexing function to avoid triggering this alarm.
- How to clear the alarm: DI.ARST
|
| WARNING / AL239 Second development platform - the argument of the LOOP_CMD command is out of range |
Condition/Cause: Condition: When the LOOP_CMD command is used, the input argument is out of range. - Incorrect use of the command of the second development platform.
Remedy: - Refer to the command descriptions for the second development platform to ensure the correct use of the commands. If the issue persists, contact the local distributor or technician.
- How to clear the alarm: DI.ARST
|
| WARNING / AL23F Second development platform - parameter is written to a memory address that is out of range |
Condition/Cause: Condition: The parameter is written to a memory address that is out of range. - Incorrect use of the command of the second development platform.
Remedy: - Refer to the command descriptions for the second development platform to ensure correct use. If the issue persists, contact the distributor or technician.
- How to clear the alarm: DI.ARST
|
| WARNING / AL245 PR positioning timeout |
Condition/Cause: Condition: PR positioning function is triggered, but the time for executing is too long. - The time for executing positioning is too long.
Remedy: - Check if the conditions for completing the PR commands are not set or not triggered, causing the command to be incomplete.
- How to clear the alarm: DI.ARST or cycle power on the servo drive.
|
| WARNING / AL262 Second development platform - read / write address in the master mode is out of range |
Condition/Cause: Condition: When you use the read / write command in the master mode, the specified address is out of range. - The specified address is out of range.
Remedy: - Refer to the command descriptions for the second development platform to ensure the correct use of the commands. If the issue persists, contact the local distributor or technician.
- How to clear the alarm: DI.ARST
|
| WARNING / AL283 Software positive limit |
Condition/Cause: Condition: The target position specified by the command exceeds the software positive limit. - The software positive limit is triggered.
Remedy: - The limit is determined by the Position command, not actual feedback. The actual position may not have exceeded the limit. Set the appropriate deceleration time to achieve the desired effect (refer to P5.003).
- How to clear the alarm: The alarm is automatically cleared after the motor moves away from the limit.
|
| WARNING / AL285 Software negative limit |
Condition/Cause: Condition: The target position specified by the command exceeds the software negative limit. - The software negative limit is triggered.
Remedy: - The limit is determined by the Position command. The actual position may not have exceeded the limit. Set the appropriate deceleration time to achieve the desired effect (refer to P5.003).
- How to clear the alarm: The alarm is automatically cleared after the motor moves away from the limit.
|
| WARNING / AL289 Position counter overflows |
Condition/Cause: Condition: Position counter overflows. - Position counter overflows.
Remedy: - Set the gear ratio according to application requirements to avoid overflow.
- If P2.069.Z is set to 1, set P2.070 [Bit 2] to 1 to prevent indexing coordinate from overflow.
- How to clear the alarm: DI.ARST
|
| WARNING / AL301 CANopen synchronization failure |
Condition/Cause: Condition: The synchronization with the controller fails when you use the CANopen IP mode (in B mode). - Communication fails to synchronize.
Remedy: - Make sure the communication between the servo drive and controller is good.
- Allow the controller to re-send the synchronization signal.
- Modify the setting for P3.009 (the default value is suggested).
- How to clear the alarm: NMT: reset node or 0x6040 fault reset.
|
| WARNING / AL380 Position offset alarm for DO.MC_OK |
Condition/Cause: Condition: DO.MC_OK is on and then goes off. - There might be an external force causing the position offset of the motor after positioning is complete.
Remedy: - Refer to the description of P1.048. Disable this alarm by setting P1.048.Y to 0.
- How to clear the alarm: DI.ARST
|
| WARNING / AL3CF Emergency stop |
Condition/Cause: Condition: After AL35F is triggered and the motor has decelerated to 0, this alarm occurs.
Remedy: - Check if any of the parameters, P2.010 - P2.017 and P2.036 - P2.040, is set to DI(0x47) and is triggered.
- How to clear the alarm: Cycle power on the servo drive.
|
| WARNING / AL401 NMT reset command is received when servo is on |
Condition/Cause: Condition: NMT reset command is received when the servo is on. - NMT reset command is received when the servo is on.
Remedy: - Check if the NMT reset command is received when the servo is on. Use NMT: reset node or 0x6040 fault reset.
- How to clear the alarm: DI.ARST
|
| WARNING / AL404 PR special filter setting value is too great |
Condition/Cause: Condition: The value of the PR command special filter (P1.022) is set too great, causing the internal position error to exceed the allowable range. - The following error of the internal position exceeds the allowable range.
Remedy: - Check the setting of P1.022. If the value is too great, adjust the value of P1.022.
- How to clear the alarm: DI.ARST
|
| WARNING / AL422 Write-in failed caused by power supply cut-off |
Condition/Cause: Condition: If P2.069.Z is set to 1 and the power supply is cut off, the motor fails to store the current position. - The load is over the rated range and the servo drive is in a continuous overload condition.
- After firmware update, the internal variables vary.
- The servo drive hardware EEPROM is abnormal.
- The hardware of the servo drive is short-circuited.
- AL520 occurred and causes malfunction of the servo drive.
Remedy: - Set P0.002 to 12 for monitoring if the average load rate is continuously over 100%. If so, increase motor capacity or reduce the load.
- If the issue persists, send your servo drive back to the distributor or contact Delta.
- How to clear the alarm: Cycle power on the servo drive.
|
| WARNING / AL500 STO function is enabled |
Condition/Cause: Condition: Safe torque off function (STO) is enabled. - Safe torque off function (STO) is enabled.
Remedy: - Check why STO is enabled.
- Reset by using DI.ARST (Alarm reset), 0x6040 fault reset, or setting P0.001 to 0.
- If not using the STO function, plug the short circuit terminal into CN10 or wire to short-circuit the block.
- How to clear the alarm: Reset the alarm or disable the STO function if not in use.
|
| WARNING / AL501 STO_A lost (signal loss or signal error) |
Condition/Cause: Condition: Loss of STO_A signal or STO_A and STO_B signals are not synchronized for more than 1 second. - Loss of STO_A signal or lack of synchronization with STO_B.
Remedy: - Make sure the wiring of STO_A is correct.
- How to clear the alarm: Cycle power on the servo drive.
|
| WARNING / AL502 STO_B lost (signal loss or signal error) |
Condition/Cause: Condition: Loss of STO_B signal or STO_A and STO_B signals are not synchronized for more than 1 second. - Loss of STO_B signal or lack of synchronization with STO_A.
Remedy: - Make sure the wiring of STO_B is correct.
- How to clear the alarm: Cycle power on the servo drive.
|
| WARNING / AL503 STO self-diagnostic error |
Condition/Cause: Condition: An error occurs during STO self-diagnosis, which may be caused by an abnormality in the STO circuit. - An abnormality in the STO circuit.
Remedy: - N/A
- How to clear the alarm: Contact the distributor.
|
| WARNING / AL510 Internal parameter update program of the servo drive is abnormal |
Condition/Cause: Condition: Internal parameter update program of the servo drive is abnormal. - Internal parameter update program is abnormal.
Remedy: - If this alarm occurs when the motor parameter identification function is executing, cycle power on the servo drive and re-execute the function.
- How to clear the alarm: N/A
|
| WARNING / AL520 Calculation program timeout |
Condition/Cause: Condition: Servo drive calculation program timeout. - Servo drive calculation program timeout.
Remedy: - Cycle power on the servo drive.
- If the alarm persists, disable the vibration elimination function by setting [Bit 8] and [Bit 9] of P2.094 to 0.
- How to clear the alarm: N/A
|
| WARNING / AL521 Vibration elimination parameter error |
Condition/Cause: Condition: The input value for the vibration elimination parameter is not appropriate. - Your input value for the vibration elimination parameter is not appropriate.
- The Bode plot is in error due to other factors while the operation system is analyzing the program.
Remedy: - Perform system analysis again and correctly set the value for the vibration elimination parameter.
- If the issue persists, disable the vibration elimination function by setting [Bit 8] and [Bit 9] of P2.094 to 0.
- How to clear the alarm: Correct parameter or disable function.
|
| WARNING / AL555 System failure |
Condition/Cause: Condition: Servo drive DSP is in error. - Servo drive DSP is in error.
Remedy: - If this alarm occurs, send your servo drive directly back to Delta without making any modification.
- How to clear the alarm: N/A
|
| WARNING / AL809 PR arithmetic operation error or second development platform error |
Condition/Cause: Condition: An error occurs when the servo drive decodes the motion command. - The PR arithmetic operation must be compiled by the ASDA-Soft software before being downloaded. Editing or modifying the PR parameters through the panel or controller without compiling them triggers AL809.
Remedy: - Make sure you edit the PR arithmetic operation parameters through ASDA-Soft. Do not modify these parameters through the panel or controller.
- If this alarm occurs when the servo is not in the PR mode, save the parameter file and provide it to the distributor.
- For advanced users: save the scope screenshot when the alarm occurs.
- How to clear the alarm: Cycle power on the servo drive.
|
| WARNING / ALD00 MITUTOYO encoder - overspeed |
Condition/Cause: Condition: An error occurred to the MITUTOYO encoder. - The motor speed exceeds 3 m/s.
- The installation or wiring of the encoder is incorrect.
- The installation and operating environment do not meet the specifications.
- The encoder is damaged.
Remedy: - Make sure the encoder or read head is correctly installed and wired according to the manufacturer's instruction manual.
- If the issue persists, contact the distributor of the encoder.
- How to clear the alarm: DI.ARST or cycle power on the servo drive.
|
| WARNING / ALD01 MITUTOYO encoder - initialization error |
Condition/Cause: Condition: An error occurred to the MITUTOYO encoder. - Initialization status error.
- Incorrect installation or wiring.
- Environment does not meet specifications.
- The encoder is damaged.
Remedy: - Make sure the encoder or read head is correctly installed and wired according to the manufacturer's instruction manual.
- If the issue persists, contact the distributor of the encoder.
- How to clear the alarm: DI.ARST or cycle power on the servo drive.
|
| WARNING / ALD02 MITUTOYO encoder - hardware error |
Condition/Cause: Condition: An error occurred to the MITUTOYO encoder. - The encoder hardware signal is in error.
- Incorrect installation or wiring.
- Environment does not meet specifications.
- The encoder is damaged.
Remedy: - Make sure the encoder or read head is correctly installed and wired.
- If the issue persists, contact the distributor of the encoder.
- How to clear the alarm: DI.ARST or cycle power on the servo drive.
|
| WARNING / ALD03 MITUTOYO encoder - absolute position detection error |
Condition/Cause: Condition: An error occurred to the MITUTOYO encoder. - The absolute position is in error.
- Incorrect installation or wiring.
- Environment does not meet specifications.
- The encoder is damaged.
Remedy: - Make sure the encoder or read head is correctly installed and wired.
- If the issue persists, contact the distributor of the encoder.
- How to clear the alarm: DI.ARST or cycle power on the servo drive.
|
| WARNING / ALD04 MITUTOYO encoder - sensor or read head error |
Condition/Cause: Condition: An error occurred to the MITUTOYO encoder. - The sensor signal is in error.
- Incorrect installation or wiring.
- Environment does not meet specifications.
- The encoder is damaged.
Remedy: - Make sure the encoder or read head is correctly installed and wired.
- If the issue persists, contact the distributor of the encoder.
- How to clear the alarm: DI.ARST or cycle power on the servo drive.
|
| WARNING / ALD05 MITUTOYO encoder - sensor signal strength error |
Condition/Cause: Condition: An error occurred to the MITUTOYO encoder. - The signal strength of the sensor is in error and the position data may contain errors.
- Incorrect installation or wiring.
- Environment does not meet specifications.
- The encoder is damaged.
Remedy: - Make sure the encoder or read head is correctly installed and wired.
- If the issue persists, contact the distributor of the encoder.
- How to clear the alarm: DI.ARST or cycle power on the servo drive.
|
| WARNING / ALD06 MITUTOYO encoder - sensor signal strength warning |
Condition/Cause: Condition: An error occurred to the MITUTOYO encoder. - The signal strength of the sensor is in error, but the position data does not contain errors.
- Incorrect installation or wiring.
- Environment does not meet specifications.
- The encoder is damaged.
Remedy: - Make sure the encoder or read head is correctly installed and wired.
- If the issue persists, contact the distributor of the encoder.
- How to clear the alarm: DI.ARST or cycle power on the servo drive.
|
| WARNING / ALD07 MITUTOYO encoder - temperature warning |
Condition/Cause: Condition: An error occurred to the MITUTOYO encoder. - The internal temperature of the encoder is over 65°C (149°F).
- Incorrect installation or wiring.
- Environment does not meet specifications.
- The encoder is damaged.
Remedy: - Make sure the encoder or read head is correctly installed and wired.
- If the issue persists, contact the distributor of the encoder.
- How to clear the alarm: DI.ARST or cycle power on the servo drive.
|
| WARNING / ALD08 BISS C encoder - sensor installation error |
Condition/Cause: Condition: An error occurred to the BISS C encoder. - Incorrect installation or wiring.
- Environment does not meet specifications.
- The encoder is damaged.
Remedy: - Make sure the encoder or read head is correctly installed and wired.
- If the issue persists, contact the distributor of the encoder.
- How to clear the alarm: DI.ARST or cycle power on the servo drive.
|
| WARNING / ALD09 BISS C encoder - sensor installation warning |
Condition/Cause: Condition: An error occurred to the BISS C encoder. - Incorrect installation or wiring.
- Environment does not meet specifications.
- The encoder is damaged.
Remedy: - Make sure the encoder or read head is correctly installed and wired.
- If the issue persists, contact the distributor of the encoder.
- How to clear the alarm: DI.ARST or cycle power on the servo drive.
|
| WARNING / ALD16 EnDat 2.2 encoder - sensor installation error |
Condition/Cause: Condition: An error occurred to the EnDat 2.2 encoder. - Incorrect installation or wiring.
- Environment does not meet specifications.
- The encoder is damaged.
Remedy: - Make sure the encoder or read head is correctly installed and wired.
- If the issue persists, contact the distributor of the encoder.
- How to clear the alarm: DI.ARST or cycle power on the servo drive.
|
| WARNING / ALD17 EnDat 2.2 encoder - sensor signal strength error |
Condition/Cause: Condition: An error occurred to the EnDat 2.2 encoder. - Incorrect installation or wiring.
- Environment does not meet specifications.
- The encoder is damaged.
Remedy: - Make sure the encoder or read head is correctly installed and wired.
- If the issue persists, contact the distributor of the encoder.
- How to clear the alarm: DI.ARST or cycle power on the servo drive.
|
| WARNING / ALD18 EnDat 2.2 encoder - position error |
Condition/Cause: Condition: An error occurred to the EnDat 2.2 encoder. - Incorrect installation or wiring.
- Environment does not meet specifications.
- The encoder is damaged.
Remedy: - Make sure the encoder or read head is correctly installed and wired.
- If the issue persists, contact the distributor of the encoder.
- How to clear the alarm: DI.ARST or cycle power on the servo drive.
|
| WARNING / ALD19 EnDat 2.2 encoder - overvoltage |
Condition/Cause: Condition: An error occurred to the EnDat 2.2 encoder. - Incorrect installation or wiring.
- Environment does not meet specifications.
- The encoder is damaged.
Remedy: - Make sure the encoder or read head is correctly installed and wired.
- If the issue persists, contact the distributor of the encoder.
- How to clear the alarm: DI.ARST or cycle power on the servo drive.
|
| WARNING / ALD20 EnDat 2.2 encoder - undervoltage |
Condition/Cause: Condition: An error occurred to the EnDat 2.2 encoder. - Incorrect installation or wiring.
- Environment does not meet specifications.
- The encoder is damaged.
Remedy: - Make sure the encoder or read head is correctly installed and wired.
- If the issue persists, contact the distributor of the encoder.
- How to clear the alarm: DI.ARST or cycle power on the servo drive.
|
| WARNING / ALD21 EnDat 2.2 encoder - overcurrent |
Condition/Cause: Condition: An error occurred to the EnDat 2.2 encoder. - The installation or wiring of the encoder is incorrect.
- The installation and operating environment do not meet the specifications, causing encoder error.
- The encoder is damaged.
Remedy: - Make sure the encoder or read head is correctly installed and wired according to the manufacturer's instruction manual.
- If the issue persists, contact the distributor of the encoder.
- How to clear the alarm: DI.ARST or cycle power on the servo drive.
|
| WARNING / ALD22 EnDat 2.2 encoder - low battery voltage |
Condition/Cause: Condition: An error occurred to the EnDat 2.2 encoder. - The installation or wiring of the encoder is incorrect.
- The installation and operating environment do not meet the specifications, causing encoder error.
- The encoder is damaged.
Remedy: - Make sure the encoder or read head is correctly installed and wired according to the manufacturer's instruction manual.
- If the issue persists, contact the distributor of the encoder.
- How to clear the alarm: DI.ARST or cycle power on the servo drive.
|
| WARNING / ALD23 EnDat 2.2 encoder - frequency collision warning |
Condition/Cause: Condition: An error occurred to the EnDat 2.2 encoder. - The installation or wiring of the encoder is incorrect.
- The installation and operating environment do not meet the specifications, causing encoder error.
- The encoder is damaged.
Remedy: - Make sure the encoder or read head is correctly installed and wired according to the manufacturer's instruction manual.
- If the issue persists, contact the distributor of the encoder.
- How to clear the alarm: DI.ARST or cycle power on the servo drive.
|
| WARNING / ALD24 EnDat 2.2 encoder - temperature warning |
Condition/Cause: Condition: An error occurred to the EnDat 2.2 encoder. - The installation or wiring of the encoder is incorrect.
- The installation and operating environment do not meet the specifications, causing encoder error.
- The encoder is damaged.
Remedy: - Make sure the encoder or read head is correctly installed and wired according to the manufacturer's instruction manual.
- If the issue persists, contact the distributor of the encoder.
- How to clear the alarm: DI.ARST or cycle power on the servo drive.
|
| WARNING / ALD25 EnDat 2.2 encoder - sensor signal strength warning |
Condition/Cause: Condition: An error occurred to the EnDat 2.2 encoder. - The installation or wiring of the encoder is incorrect.
- The installation and operating environment do not meet the specifications, causing encoder error.
- The encoder is damaged.
Remedy: - Make sure the encoder or read head is correctly installed and wired according to the manufacturer's instruction manual.
- If the issue persists, contact the distributor of the encoder.
- How to clear the alarm: DI.ARST or cycle power on the servo drive.
|
| WARNING / ALD26 EnDat 2.2 encoder - low battery voltage warning |
Condition/Cause: Condition: An error occurred to the EnDat 2.2 encoder. - The installation or wiring of the encoder is incorrect.
- The installation and operating environment do not meet the specifications, causing encoder error.
- The encoder is damaged.
Remedy: - Make sure the encoder or read head is correctly installed and wired according to the manufacturer's instruction manual.
- If the issue persists, contact the distributor of the encoder.
- How to clear the alarm: DI.ARST or cycle power on the servo drive.
|
| WARNING / ALE03 Fagor encoder - position error |
Condition/Cause: Condition: An error occurred to the Fagor encoder. - Analog signal of the sensor < 0.2 Vpp.
- The installation or wiring of the encoder is incorrect.
- The installation and operating environment do not meet the specifications.
- The encoder is damaged.
Remedy: - Make sure the encoder or read head is correctly installed and wired according to the manufacturer's instruction manual.
- If the issue persists, contact the distributor of the encoder.
- How to clear the alarm: DI.ARST
|
| WARNING / ALE06 Fagor encoder - overspeed warning |
Condition/Cause: Condition: An error occurred to the Fagor encoder. - The motor speed is too fast and has exceeded the maximum value of the encoder.
- The installation or wiring of the encoder is incorrect.
- The installation and operating environment do not meet the specifications.
- The encoder is damaged.
Remedy: - Make sure the encoder or read head is correctly installed and wired according to the manufacturer's instruction manual.
- If the issue persists, contact the distributor of the encoder.
- How to clear the alarm: DI.ARST
|
| WARNING / ALE07 Fagor encoder - temperature warning |
Condition/Cause: Condition: An error occurred to the Fagor encoder. - The encoder temperature has exceeded the maximum value.
- The installation or wiring of the encoder is incorrect.
- The installation and operating environment do not meet the specifications.
- The encoder is damaged.
Remedy: - Make sure the encoder or read head is correctly installed and wired according to the manufacturer's instruction manual.
- If the issue persists, contact the distributor of the encoder.
- How to clear the alarm: DI.ARST
|
| WARNING / ALF21 Second development platform command error |
Condition/Cause: Condition: The use of the second development platform commands does not comply with the specifications. - Refer to the error codes.
Remedy: View the error code by checking the ERR register with the EzASD software or by pressing the SHIFT key when the panel displays ALF21. | Error code | Description |
|---|
| 0x0203 | Task number is out of range when the command for configuring the task is used. | | 0x0207 | The parameter group (grp) value of the LACC_PR or SACC_PR command is out of range. | | 0x0209 | The parameter index (idx) value of the LACC_PR or SACC_PR command is out of range. | | 0x0211 | Parameter setting of Type [8] PR is in error. | | 0x0213 | The value written to the SACC_PR command exceeds the setting range of the specific parameter. | | 0x0215 | This parameter is read-only, so the SACC_PR command cannot be written. | | 0x0217 | In the Servo On state, the SACC_PR command cannot be written. | | 0x0219 | This parameter is write-protected, so the SACC_PR command cannot be written. Check if the parameter and data array protection function (P5.097) is enabled. | | 0x021B | The stack space is insufficient. | | 0x021D | Used the division (DIV) command, but the divisor is 0. | | 0x0221 | The mode specified by the argument of the MODE command is undefined. | | 0x0223 | When the servo drive is in the Servo Off or Quick Stop state, some motion command operations are invalid. | | 0x022D | When the E-Cam is engaged, the PABS command is unavailable. | | 0x0231 | The index value (monitoring variable number) of the LACCL_SV or SACCL_SV command is out of range. | | 0x0235 | The overflow of the absolute position causes the PABS command to be unavailable. Execute the homing procedure. | | 0x0239 | The loop mode specified by the argument of the LOOP_CMD command is undefined. | | 0x023F | The register storage command accesses the wrong memory space with the pointer. | | 0x0245 | The wait command exceeded the time limit. Use the TIMEOUT command to adjust the maximum waiting time. | | 0x0247 | Called a math function with the index out of range. | | 0x0251 | Argument of the power command is not within the range of 0 - 10. | | 0x0255 | Argument of the object call command is out of range. | | 0x0257 | Non-existing object index. | | 0x025B | Object call error (ID, Version, Size). | | 0x025F | An error occurs when OD is accessed. | | 0x0261 | P3.005.Y is not set to 1, so the servo drive cannot read / write the Modbus object. | | 0x0262 | When the Modbus object is used, the read / write packet length exceeds the limit. | How to clear the alarm: Cycle power on the servo drive.
|
| WARNING / ALF22 Password does not match |
Condition/Cause: Condition: The password of the second development platform project does not match that of the servo drive. - The password of the second development platform project does not match that of the servo drive.
Remedy: - Check if the password of the second development platform and the password of the servo drive are input correctly.
- You can change the project password with the EzASD software, but you cannot reset the password.
- You can change the servo drive password with the EzASD software. You can also set P2.008 to 10 to reset the servo drive password (this also clears all parameters and stored projects).
|