Delta ASDA-AB Servo Drive Fault Codes & Diagnostic Guide
Complete fault code directory, alarm root causes, and step-by-step troubleshooting procedures for the Delta ASDA-AB standard AC servo drive series. Search or filter through the complete diagnostic database below.
Power Range
100 W – 3.0 kW (0.1 – 3 kW)
Supply Voltage
200–230V AC (1-Ph / 3-Ph)
Control Modes
Pt / Pr (Position), Speed & Torque
Operator Interface
Built-in 5-Digit LED Keypad
Complete Delta ASDA-AB Servo Drive Fault Code Directory
Use the search box in the table below to quickly find your alarm code (e.g., type AL001, AL003, AL011, or Overcurrent).
| Fault Code and Meaning | Cause and Remedy |
|---|---|
| ALE01 Overcurrent | Cause:
Remedy:
|
| ALE02 Overvoltage | Cause:
Remedy:
|
| ALE03 Undervoltage | Cause:
Remedy:
|
| ALE04 Z Pulse shift | Cause:
Remedy:
|
| ALE05 Regeneration error | Cause:
Remedy:
|
| ALE06 Overload | Cause:
Remedy:
|
| ALE07 Overspeed | Cause:
Remedy:
|
| ALE08 Abnormal pulse control command | Cause:
Remedy:
|
| ALE09 Excessive deviation | Cause:
Remedy:
|
| ALE10 Watch dog execution time out | Cause:
Remedy:
|
| ALE11 Encoder error (Position detector fault) | Cause:
Remedy:
|
| ALE12 Adjustment error | Cause:
Remedy:
|
| ALE13 Emergency stop activated | Cause:
Remedy:
|
| ALE14 Reverse (CWL) limit switch error | Cause:
Remedy:
|
| ALE15 Forward (CCWL) limit switch error | Cause:
Remedy:
|
| ALE16 IGBT temperature error | Cause:
Remedy:
|
| ALE17 Memory error | Cause:
Remedy:
|
| ALE18 DSP communication error | Cause:
Remedy:
|
| ALE19 Serial communication error | Cause:
Remedy:
|
| ALE20 Serial communication time out | Cause:
Remedy:
|
| ALE21 Command write-in error | Cause:
Remedy:
|
| ALE22 Input power phase loss | Cause:
Remedy:
|
| ALE23 Pre-overload warning | Cause:
Remedy:
|
| ALE96 The frequency of the entered parameter is abnormal | Cause:
Remedy:
|
| ALE97 Internal command execution time out | Cause:
Remedy:
|
| ALE98 DSP communication error | Cause:
Remedy:
|
| ALE99 DSP communication error | Cause:
Remedy:
|
How to Clear & Reset Delta ASDA-AB Servo Drive Faults
- Digital Input Reset (ARST): Trigger the digital input terminal (DI1–DI8 on connector CN1) configured to function 0x02 (ARST – Alarm Reset) in parameters P2-10 to P2-17 once the underlying fault cause is resolved.
- ASDASoft PC Diagnostic Tool: Connect a PC using an RS-232/RS-485 communication cable to connector CN3, launch Delta ASDASoft, and click “Alarm Reset” in the Digital I/O or Diagnostic status tab.
- Keypad Reset / Clear: Press the MODE / ENTER keys on the built-in 5-digit LED front operator keypad to acknowledge and dismiss recoverable alarms.
- Parameter Factory Default Reset: Set parameter P2-08 to 10 to restore all parameters to default factory settings if EEPROM data corruption is suspected, then power-cycle the drive.
- Power Cycle: Disconnect AC main circuit power (R, S, T) and control circuit power (r, t), wait at least 5 minutes until the 5-digit LED display and red CHARGE lamp extinguish completely, then re-apply power.
⚠️ High-Voltage Electrical Safety Warning:
Always verify with a calibrated digital multimeter that intermediate DC bus voltage measures strictly below 25VDC across terminals [+1/+] and [-], and verify that the red CHARGE LED is completely extinguished before inspecting servo motor wiring, checking incremental encoder cables, or touching terminals U, V, and W on the Delta ASDA-AB servo drive.