Delta ASDA-B Servo Drive Fault Codes & Diagnostic Guide
Complete alarm code reference directory, trip error causes, and field troubleshooting procedures for the Delta ASDA-B standard AC servo drive series. Search or filter through the complete alarm directory below.
Power Range
0.1 – 2.0 kW (100W – 2 kW)
Supply Voltage
200–230V AC (1-Ph / 3-Ph)
Control Modes
Position (PT), Speed, & Torque
Operator Interface
5-Digit 7-Segment Display / ASDA-Soft
Complete Delta ASDA-B Servo Drive Fault Code Directory
Use the search box in the table below to quickly find your alarm code (e.g., type AL001, AL003, AL009, or Overcurrent).
| Fault Code and Meaning | Cause and Remedy |
|---|---|
| ALE 1 Overcurrent | Cause: Short-circuit at drive output (U, V, W), Motor wiring error, IGBT error, or Heat sink overheated. Remedy:
|
| ALE 2 Overvoltage | Cause: Main circuit voltage exceeded maximum allowable value, Power input error (incorrect input), or Servo drive hardware damage. Remedy:
|
| ALE 3 Undervoltage | Cause: Main circuit voltage below minimum value, No input voltage at main circuit, Power input error, or Hardware damage. Remedy:
|
| ALE 4 Z Pulse shift | Cause: Encoder is damaged or Encoder is loose. Remedy:
|
| ALE 5 Regeneration error | Cause: Regenerative resistor not connected, Transistor for regeneration disabled/short-circuited, Parameter setting error, or Hardware damage. Remedy:
|
| ALE 6 Overload | Cause: Drive exceeded rated load, Control system parameter incorrect (Gain/Accel/Decel), Wiring error, Encoder damaged, or Incorrect U, V, W connection. Remedy:
|
| ALE 7 Overspeed | Cause: Wiring of motor incorrect, Encoder damaged, Speed input command unstable, or Over-speed parameter setting defective. Remedy:
|
| ALE 8 Abnormal pulse control command | Cause: Pulse command frequency is higher than rated input frequency. Remedy:
|
| ALE 9 Excessive deviation | Cause: Maximum deviation parameter too small, Torque limit too low, Overload, Gain value too small, or Too much fluctuation of pulse command. Remedy:
|
| ALE 10 Serial communication error | Cause: Communication parameter setting defective, Communication address incorrect, or Communication value incorrect. Remedy:
|
| ALE 11 Encoder error (Position detector fault) | Cause: Wiring of encoder in error/defective, Encoder is loose, or Encoder is damaged. Remedy:
|
| ALE 12 Adjustment error | Cause: Motor is running during adjustment, Analog input contact does not return to zero, or Detection device damaged. Remedy:
|
| ALE 13 Emergency stop activated | Cause: Emergency stop switch is activated. Remedy:
|
| ALE 14 Reverse (CWL) limit switch error | Cause: Reverse limit switch is activated or Servo system is not stable. Remedy:
|
| ALE 15 Forward (CCWL) limit switch error | Cause: Forward limit switch is activated or Servo system is not stable. Remedy:
|
| ALE 16 IGBT temperature error | Cause: The drive has exceeded its rated load during continuous operation. (Check: Check if there is overload or the motor current is too high). Remedy:
Cause: Short-circuit at drive output. (Check: Check the drive input wiring). Remedy:
|
| ALE 17 Memory error | Cause: Data error in Memory read-out / write-in. (Check: Reset parameter or power supply). Remedy:
|
| ALE 18 Serial communication time out | Cause: Setting value in time out parameter is not correct. (Check: Check communication time out parameter setting). Remedy:
Cause: Not receiving communication command for a long time. (Check: Check whether communication cable is loose or broken). Remedy:
|
| ALE 19 Motor type error | Cause: Servo drive and servo motor do not match. (Check: Check the type of servo drive and servo motor and their combination). Remedy:
|
| ALE 20 Input power phase loss | Cause: Control power supply is in error. (Check: Check the power cable and connections of R, S, T. Check whether the power cable is loose or the possible loss of phase on input power). Remedy:
|
| ALE 30 LCM hardware error | Cause: No display. (Check: Check if the 4th Pin of LCM is normal). Remedy:
Cause: Error characters display. (Check: Check if the related Pins are short-circuited and check if IC operation is normal). Remedy:
|
| ALE 31 LED hardware error | Cause: LED indicator is abnormal. (Check: Check if LED is normal. Check if the transistor is abnormal and check if IC operation is normal by setting P8-09 to 2). Remedy:
|
| ALE 32 KEY hardware error | Cause: The function key is disabled. (Check: Check if IC operation is normal by setting P8-09 to 1). Remedy:
|
| ALE 33 RAM hardware error | Cause: LCM display is abnormal (disorganized display). (Check: Please check if the working voltage of RAM is normal). Remedy:
Cause: Function key is abnormal. (Check: Check if the transistor is abnormal and check if IC operation is normal by setting P8-09 to 3). Remedy:
|
| ALE 34 EEPROM hardware error | Cause: Store data error. (Check: Check if the operation of MCU or EEPROM is normal by setting P8-09 to 4). Remedy:
|
| ALE 35 COMM hardware error | Cause: Hardware error. (Check: Check if the serial communication signal is normal). Remedy:
Cause: Communication parameter setting is defective. (Check: Check the communication parameter setting). Remedy:
|
| ALE 40 Initial setup error | Cause: Communication error occurs when initial setup. (Check: Communication initial setup has not completed yet. Please check if the communication serial signal is normal). Remedy:
Cause: Parameter read error when initial setup. (Check: EEPROM cannot read normally. Set P8-09 to 4 to test EEPROM and check if EEPROM is normal). Remedy:
Cause: Communication mode is error. (Check: Check if using ASDA series servo drive). Remedy:
|
| ALE 41 Communication receive time out | Cause: Not receiving communication data for a long time. (Check: Check if the communication cable is loose or broken). Remedy:
Cause: Data receiving is not completed. (Check: Check if the serial communication signal is normal). Remedy:
|
| ALE 42 Communication receive error | Cause: Checksum error. (Check: Check if the checksum of the receiving data is correct). Remedy:
Cause: Checksum error. (Check: Check the communication quality). Remedy:
|
| ALE 43 Error communication response address | Cause: Receive the error communication response address. (Check: Check if the sending and receiving communication address are the same). Remedy:
|
| ALE 44 Error communication response command | Cause: Respond the error communication command. (Check: Respond the error Modbus command). Remedy:
|
| ALE 45 Communication parameter address error | Cause: Respond the error parameter address. (Check: Check if the sending and receiving communication code are the same). Remedy:
|
| ALE 46 Communication parameter content error | Cause: Respond error parameter content when reading parameter. (Check: The data length of the content is error). Remedy:
Cause: Respond error parameter content when writing parameter. (Check: The data content is in error). Remedy:
|
| ALE 47 Drive specification error | Cause: Parameter SAVE operation is in error. (Check: Use P8-13 to check if the specification stored in the memory block match the actual servo drive specification when executing SAVE function). Remedy:
Cause: Parameter WRITE operation is in error. (Check: Use P8-13 to check if the specification stored in the memory block match the actual servo drive specification when executing WRITE function). Remedy:
|
| ALE 48 Fast editing function error | Cause: The function of static and auto-tuning is in error. (Check: The setting of P2-32 is incorrect). Remedy:
Cause: The function of dynamic auto-tuning is in error. (Check: Execution time out or the function is not executed completely). Remedy:
|
How to Clear & Reset Delta ASDA-B Servo Drive Faults
- Keypad Reset: Once the root cause of the error is resolved, press and hold the SHIFT / ENTER key on the front 5-digit LED keypad panel to reset clearable alarm codes.
- Digital Input Reset (ARST): Pulse the multi-function digital input assigned to ARST (Alarm Reset) (Function code
0x02assigned to DI1–DI4 via parameters P2-10 to P2-13). - ASDA-Soft PC Tool: Connect your computer through the serial communication port (RS-232 / RS-485), open ASDA-Soft, navigate to the diagnostic/status monitor, and select “Alarm Reset”.
- Factory Parameter Restoration: To reinitialize all parameters back to default settings, access parameter P2-08 and set it to 10 (or 1), then execute a power cycle.
- Complete AC Power Cycle: Disconnect incoming mains AC supply power (terminals R, S, T / L1, L2), wait until the 5-digit LED screen and red CHARGE LED turn completely off (approx. 5 minutes for capacitor discharge), then reconnect power.
⚠️ High-Voltage Electrical Safety Warning:
Hazardous electrical energy remains stored in intermediate DC bus capacitors even after mains power is disconnected. Always wait until the red CHARGE LED turns completely OFF, and verify with a calibrated multimeter that DC bus voltage across terminals P⊕ and D/C measures below 25VDC before touching terminals or servicing servo motor phase leads (U, V, W).