Hitachi WJ-C1 Drive Fault Codes & Diagnostic Guide
Complete fault code reference directory, trip alarm causes, and step-by-step diagnostic procedures for the Hitachi WJ-C1 compact multi-purpose inverter series. Search or filter through the complete fault code directory below.
Power Range
0.1 – 15 kW (0.125 – 20 HP)
Supply Voltage
1-Ph 100–240V / 3-Ph 200–480V AC
Control Modes
Sensorless Vector (SLV) & V/f
Operator Interface
Built-in LED Keypad / Optional WOP LCD
Complete Hitachi WJ-C1 Drive Fault Code Directory
Use the search box in the table below to quickly find your code (e.g., type E01, E07, E030, or Overcurrent).
| Fault Code and Meaning | Cause and Remedy |
|---|---|
| E01.* Over current error (Constant speed) | Cause:
Remedy:
|
| E02.* Over current error (During deceleration) | Cause: Rapid deceleration. Remedy:
|
| E03.* Over current error (During acceleration) | Cause:
Remedy:
|
| E04.* Over current error (Other) | Cause: Is DC braking high? Remedy:
|
| E05.* Overload error | Cause:
Remedy:
|
| E06.* Braking resistor overload error | Cause:
Remedy:
|
| E07.* Overvoltage error | Cause:
Remedy:
|
| E08.* Memory error | Cause:
Remedy:
|
| E09.* Undervoltage error | Cause:
Remedy:
|
| E10.* Current detector error | Cause: Inverter failure. Remedy:
|
| E11.* CPU error | Cause:
Remedy:
|
| E12.* External trip error | Cause:
Remedy:
|
| E13.* USP error | Cause: Is the power supply turned on with the RUN command input? Remedy:
|
| E14.* Ground fault | Cause:
Remedy:
|
| E15.* Power supply overvoltage error | Cause: Is the power supply voltage too high? Remedy:
|
| E19.* Temperature detection error | Cause: Inverter failure. Remedy:
|
| E21.* Cooling fin temperature error | Cause:
Remedy:
|
| E22.* CPU communication error | Cause:
Remedy:
|
| E25.* Main circuit error | Cause:
Remedy:
|
| E26.* Analog current input error | Cause:
Remedy:
|
| E30.* Driver error | Cause:
Remedy:
|
| E35.* Thermistor error (Motor temperature error) | Cause:
Remedy:
|
| E36.* Brake error | Cause:
Remedy:
|
| E37.* STO shut-off error | Cause:
Remedy:
|
| E38.* Low-speed range overload error | Cause: Is the load too heavy? Remedy:
|
| E40.* Remote operator communication error | Cause: Is there a communication error? Remedy:
|
| E41.* Modbus communication error | Cause:
Remedy:
|
| E43.* EzSQ invalid instruction error | Cause: Invalid instruction detected in EzSQ program. Remedy:
|
| E44.* EzSQ nesting count error | Cause: Nesting count exceeds allowable executed number. Remedy:
|
| E45.* EzSQ execution error | Cause: Instruction that cannot be executed is detected. Remedy:
|
| E50.* to E59.* EzSQ user-assigned error 0 to 9 | Cause: Corresponding user-assigned tripping programs executed in EzSQ. Remedy:
|
| E60.* to E69.* Option related error | Cause:
Remedy:
|
| E80.* Encoder disconnection error | Cause:
Remedy:
|
| E81.* Overspeed error | Cause:
Remedy:
|
| E83.* Position control range error | Cause: Is the current position and home position correct? Remedy:
|
| E98.* ST1/ST2 mismatch error | Cause:
Remedy:
|
| E99.* STO internal failure error | Cause: Is the safety function working properly? Remedy:
|
How to Clear & Reset Hitachi WJ-C1 Drive Faults
- Keypad Reset: Press the red STOP/RESET key on the integrated front LED operator once the trip cause is identified and cleared. For thermal protection trips (E05), allow motor and heat sink cooling time before attempting a reset.
- Intelligent Terminal Reset [RS]: Momentarily close and open the multi-function input assigned to Reset function 18 (terminal [RS], programmed via parameters C001 through C007). Turn the [RS] signal OFF to return to standby.
- ProDriveNext PC Tool / USB: Connect a PC using the front mini-USB or RS-485 interface with Hitachi ProDriveNext configuration software and execute the “Trip Reset” command from the status monitor window.
- Trip History Check: Inspect monitor parameters d081 through d086 via the keypad to verify the last 6 fault records, operating frequency, output current, and DC link voltage recorded at the exact moment of trip.
- Power Cycle: Disconnect AC input mains power, wait at least 10 minutes until the front power LED and internal DC bus charge indicator extinguish completely, then re-energize the drive.
⚠️ High-Voltage Electrical Safety Warning:
Always verify with a calibrated digital multimeter that intermediate DC bus voltage measures strictly below 50VDC across terminals [+] and [-] (or +1 and -) and wait at least 10 minutes after turning off input AC power before opening the terminal cover or touching motor terminals U/T1, V/T2, and W/T3 on the Hitachi WJ-C1 drive.