Nidec Control Techniques Commander SX Fault Codes & Diagnostic Guide
Complete trip code directory, alarm causes, and diagnostic troubleshooting steps for Nidec Control Techniques Commander SX IP66 / NEMA 4X washdown AC drives. Search and filter through the complete diagnostic list below.
Power Range
0.37 – 7.5 kW (0.5 – 10 HP)
Supply Voltage
200–240V / 380–480V AC
Control Modes
Open Loop Vector & V/Hz Control
Protection Rating
IP66 / NEMA 4X Washdown
Complete Commander SX Trip Code Directory
Use the search box in the table below to quickly find your trip code (e.g., type OI.AC, OV, PSU, th, or Overcurrent).
| Fault Code and Meaning | Cause and Remedy |
|---|---|
| cL1 ADI1 loss | Cause: Loss of the current reference on analog input ADI1. Remedy:
|
| cL2 ADI2 loss | Cause: Loss of the current reference on analog input ADI2. Remedy:
|
| cL3 ADIO3 loss | Cause: Loss of the current reference on analog input ADIO3. Remedy:
|
| EEF EEPROM fail. | Cause: Drive rating does not match with XPressKey. Remedy:
|
| enC2 Encoder rot | Cause: The measured position does not vary (the encoder is incorrectly connected or not supplied with power or the shaft is not turning). Remedy:
|
| EnC1 U sign. loss | Cause: Loss of channel U. Remedy:
|
| EnC2 V sign. loss | Cause: Loss of channel V. Remedy:
|
| EnC3 W sign. loss | Cause: Loss of channel W. Remedy:
|
| Fbus Fieldbus loss | Cause: Disconnection of the fieldbus. Remedy:
|
| It.AC Motor I²t | Cause: Motor overload I x t. Remedy:
|
| It.br Brak. resist. | Cause: Braking resistor overload I x t. Remedy:
|
| Oht1 Dv over heat | Cause: IGBT overheating (sensor). Remedy:
|
| Oht2 BR over heat | Cause: Internal resistor overheating (sensor). Remedy:
|
| OI.AC Over current | Cause: Overcurrent at drive output. Remedy:
|
| OIbr Brak.IGBT | Cause: IGBT braking overcurrent. Remedy:
|
| Old1 24V over Id | Cause: Overload on +24V source or logic output. Remedy:
|
| OSP Over speed | Cause: Overspeed. Remedy:
|
| OU DC over volt | Cause: DC bus overvoltage. Remedy:
|
| ph In Ph. loss | Cause: Phase loss. Note: The loss of one phase can only be detected if the active current is between 50% and 100% of the rated value. Remedy:
|
| Ph.AC Out Ph. loss | Cause: Motor phase loss. Remedy:
|
| rot A/B reversed | Cause: The a, b, a\, b\ signals are the wrong way round. Remedy:
|
| rS Stator res. | Cause: Stator resistance measurement fault. Remedy:
|
| SCL COM loss | Cause: Serial link fault. Remedy:
|
| Secd Sec.disable | Cause: Secure input fault. Remedy:
|
| Th Motor PTC | Cause: Motor sensor trip. Remedy:
|
| tr01 - tr10 User 1 - 10 | Cause: User fault 1 through 10 via logic input or serial link. Remedy:
|
| tun3 UVW revers. | Cause: The u, v, w switching signals are the wrong way round. Remedy:
|
| tun4 U sign.miss. | Cause: Some signals are present, but U is missing. Remedy:
|
| tun5 V sign.miss. | Cause: Some signals are present, but V is missing. Remedy:
|
| tun6 W sign.miss. | Cause: Some signals are present, but W is missing. Remedy:
|
| tun7 Pole count | Cause: The number of pairs of poles set is incorrect (the revolutions measured mechanically and electrically are inconsistent). Remedy:
|
| tunE Autotun. fail | Cause: Autocalibration error. Remedy:
|
| UU Under volt. | Cause: DC bus undervoltage. Remedy:
|
How to Clear & Reset Commander SX Drive Trips
- Keypad Reset: Press the red Stop / Reset key on the integrated front keypad. If the drive is running in keypad mode, press once to stop and a second time to clear the active trip.
- Terminal Input Reset: Remove the drive run signal or toggle an assigned digital input programmed as a trip reset (Parameter 10.38 / User Trip Reset).
- SXSoft PC Software: Connect via the serial communications interface using an RS485 converter lead, open SXSoft or CTSoft, and click “Reset Drive” on the live monitor panel.
- Serial Fieldbus (Modbus RTU): Send a trip reset command by writing a transition from `0` to `1` on the control word reset bit (Bit 3 in Parameter 06.42) via Modbus RTU communications.
- Line Power Cycle: Switch off the main AC line supply to the drive. Wait until all internal LEDs and display characters turn off completely (allow at least 5 minutes for complete discharge of the internal bus capacitors) before restoring power.
⚠️ High-Voltage Electrical Safety Warning:
Although the Commander SX features an IP66/NEMA 4X washdown enclosure, dangerous DC bus voltages remain inside after removing main AC supply power. Before opening the housing cover or working on power terminals (+DC, -DC, U, V, W), isolate the AC feed and confirm with a calibrated digital multimeter that intermediate DC bus voltage has discharged below 50VDC.