INVT MH860A Series Hydraulic Servo Fault Codes & Diagnostic Guide
Complete fault code reference directory, trip alarm causes, and step-by-step troubleshooting procedures for the INVT MH860A electro-hydraulic servo drive series. Search or filter through the complete fault code directory below.
Power Range
7.5 – 110 kW (10 – 150 HP)
Supply Voltage
380–480V AC (3-Phase)
Control Modes
Pressure/Flow (P/Q) & PMSM FOC
Feedback Interface
Rotary Transformer (Resolver) / Encoder
Complete INVT MH860A Series Drive Fault Code Directory
Use the search box in the table below to quickly find your code (e.g., type OUT1, OC1, PEr, or Overcurrent).
| Fault Code and Meaning | Cause and Remedy |
|---|---|
| Err01 IPM fault | Cause: The instantaneous output of the power module exceeds the short-circuit current. Remedy:
|
| Err02 Overcurrent | Cause: The output current exceeds the allowed working current of drive. Remedy:
|
| Err03 DC overvoltage | Cause: The DC voltage on the main circuit is abnormally high. Remedy:
|
| Err04 DC undervoltage | Cause: When the motor is powered on to run, the DC voltage on the main circuit decreases lower than the protection value. Remedy:
|
| Err05 FWD overspeed | Cause: The motor rotation speed exceeds the forward speed protection value. Remedy:
|
| Err06 Module overtemperature | Cause: The drive temperature exceeds the module protection temperature. Remedy:
|
| Err07 Motor overtemperature | Cause: The motor temperature exceeds the motor protection temperature. Remedy:
|
| Err08 Software fault | Cause: The drive software runs abnormally. Remedy:
|
| Err09 CAN fault | Cause: The drive reports the fault upon a CAN communication exception when the process command mode is continuous CAN communication input or multi-pump joint application. Remedy:
|
| Err10 Reserved | Cause: - Remedy:
|
| Err11 Self-check fault | Cause: The internal hardware of drive is abnormal. Remedy:
|
| Err12 Task re-entry | Cause: An error occurred when invoking a software program. Remedy:
|
| Err13 System overpressure | Cause: The system pressure exceeds the overpressure protection threshold. Remedy:
|
| Err14 REV overspeed | Cause: The motor rotation speed exceeds the reverse speed protection value. Remedy:
|
| Err15 Pressure sensor fault | Cause: The pressure sensor is incorrectly wired or damaged. Remedy:
|
| Err16 Braking pipe fault | Cause: The braking pipe is damaged. Remedy:
|
| Err17 AC overvoltage | Cause: The input AC voltage exceeds AC overvoltage protection. Remedy:
|
| Err18 EEPROM error | Cause: There is a drive EEPROM data exception. Remedy:
|
| Err19 Reserved | Cause: - Remedy:
|
| Err20 AC undervoltage | Cause: The input AC voltage is lower than AC undervoltage protection. Remedy:
|
| Err21 Braking resistor overload | Cause: The braking resistor overload rate exceeds the braking resistor overload threshold. Remedy:
|
| Err22 Node fault | Cause: In multi-pump parallel connection application, if a slave node encounters a fault, the master drive reports it. Remedy:
|
| Err23 Input phase loss | Cause: Input phase loss occurs or three phases are unbalanced. Remedy:
|
| Err24 Reserved | Cause: - Remedy:
|
| Err25 RS485 communication fault | Cause: The drive encounters an RS485 communication exception when the process command mode is continuous RS485 communication input. Remedy:
|
| Err26 Current feedback channel fault | Cause: The zero drift in power-on self-check is too great. Remedy:
|
| Err27 - Err32 Reserved | Cause: - Remedy:
|
| Err33 Resolver sampling fluctuation fault | Cause: When the drive is tested in diagnosis mode, the resolver sampling value fluctuates greatly. Remedy:
|
| Err34 Phase-A current sampling fluctuation fault | Cause: When the drive is tested in diagnosis mode, the phase-A current sampling value fluctuates greatly. Remedy:
|
| Err35 Phase-B current sampling fluctuation fault | Cause: When the drive is tested in diagnosis mode, the phase-B current sampling value fluctuates greatly. Remedy:
|
| Err36 Phase-A current sampling zero drift fault | Cause: When the drive is tested in diagnosis mode, the phase-A current sampling zero drift is too great. Remedy:
|
| Err37 Phase-B current sampling zero drift fault | Cause: When the drive is tested in diagnosis mode, the phase-B current sampling zero drift is too great. Remedy:
|
| Err38 DC voltage sampling fluctuation fault | Cause: When the drive is tested in diagnosis mode, the DC voltage sampling value fluctuates greatly. Remedy:
|
| Err39 Pressure feedback sampling fluctuation fault | Cause: When the drive is tested in diagnosis mode, the pressure feedback sampling value fluctuates greatly. Remedy:
|
| Err40 Pressure feedback sampling zero drift fault | Cause: When the drive is tested in diagnosis mode, the pressure feedback sampling zero drift is too great. Remedy:
|
| Err41 Pressure reference sampling fluctuation fault | Cause: When the drive is tested in diagnosis mode, the pressure reference sampling value fluctuates greatly. Remedy:
|
| Err42 Flow reference sampling fluctuation fault | Cause: When the drive is tested in diagnosis mode, the flow reference sampling value fluctuates greatly. Remedy:
|
| Err43 Reserved | Cause: - Remedy:
|
| Err44 Module temperature sampling fluctuation fault | Cause: When the drive is tested in diagnosis mode, the module temperature sampling value fluctuates greatly. Remedy:
|
| Err45 Motor temperature sampling fluctuation fault | Cause: When the drive is tested in diagnosis mode, the motor temperature sampling value fluctuates greatly. Remedy:
|
| Err46 - Err48 Reserved | Cause: - Remedy:
|
| Err49 Encoder initial angle measuring fault | Cause: During motor parameter autotuning in diagnosis mode, a fault occurs in the encoder initial angle measuring, for example, current does not follow, and timeout occurs. Remedy:
|
| Err50 Phase sequence detection fault | Cause: During motor parameter autotuning in diagnosis mode, the number of motor pole pairs is calculated incorrectly, the rotation speed limit value is invalid, current does not follow, or timeout occurs. Remedy:
|
| Err51 Motor resistance test fault | Cause: During motor parameter autotuning in diagnosis mode, current does not follow, timeout occurs, or the resistance test value is invalid. Remedy:
|
| Err52 Motor parameter dynamic test fault | Cause: During motor parameter autotuning in diagnosis mode, the speed deviation is too great, current does not follow, the load is too great, timeout occurs, or the test value is invalid. Remedy:
|
| Err53 Motor parameter static test fault | Cause: During motor parameter autotuning in diagnosis mode, the motor parameter calculation result is invalid. Remedy:
|
| Err54 Diagnosis interrupted | Cause: If a fault occurs during diagnosis, the drive terminates the diagnosis and displays "Err54". Remedy:
|
| Err55 Reserved | Cause: - Remedy:
|
| Err56 EtherCAT initialization fault | Cause: The EtherCAT chip is in poor contact. Remedy:
|
| Err57 EEPROM fault in EtherCAT communication | Cause: The EEPROM does not have data or it fails to read data. Remedy:
|
| Err58 EtherCAT disconnection | Cause: After the drive is enabled, the network cable is not inserted properly, or the EtherCAT master node does not run properly. Remedy:
|
| Err59 EtherCAT communication fault | Cause: No PDO data is received after the drive has been enabled for a period of time. Remedy:
|
How to Clear & Reset INVT MH860A Series Drive Faults
- Keypad Reset: Press the red STOP/RST key on the integrated LED keypad. Before resetting, confirm that the servo enable signal (SON) and pressure/flow cycling commands from the machine controller are turned OFF.
- Molding Machine Controller Reset (DI): If a digital input terminal (e.g., S1–S4 or HDI) is assigned to Fault Reset (function 7), send a reset pulse from the injection molding machine or hydraulic PLC to clear the latch.
- CANbus / EtherCAT Fieldbus Reset: If operating under multi-pump parallel control or bus communication (CANopen / EtherCAT EC-TX508), transmit a fault reset command via the communication control word to clear the servo alarm remotely.
- Hydraulic Auto Reset Configuration: Set parameter P08.28 (Fault reset times) and P08.29 (Fault reset interval) to allow the servo drive to automatically attempt recovery after momentary pressure fluctuations or minor voltage sags.
- Complete Power Cycle: De-energize the main incoming 3-phase AC power breaker. Wait at least 10 minutes until the LED display is completely dark and high-capacity intermediate bus capacitors fully discharge before restoring power.
⚠️ High-Voltage & Hydraulic Safety Warning:
Electro-hydraulic servo equipment contains combined electrical high-voltage and stored hydraulic pressure hazards. Always depressurize the machine hydraulic circuit, discharge accumulators, disconnect incoming AC line power, and verify with a calibrated digital multimeter that DC bus voltage across terminals [(+)] and [(-)] is strictly below 36VDC before removing junction box covers or servicing motor leads U, V, and W.