LS Electric iV5L Drive Fault Codes & Diagnostic Guide
Complete fault code reference directory, trip alarm causes, and step-by-step troubleshooting procedures for the LS Electric LSLV-iV5L elevator and lift vector drive series. Search or filter through the complete fault code directory below.
Power Range
5.5 – 22 kW (7.5 – 30 HP)
Supply Voltage
380–480V AC (3-Phase)
Control Modes
IM / PM Sensored Vector & V/F
Operator Interface
Alphanumeric LCD Keypad / Loader
Complete LS Electric iV5L Drive Fault Code Directory
Use the search box in the table below to quickly find your code (e.g., type Overcurrent, Overvoltage, Encoder Trip, or Safety Trip).
| Fault Code and Meaning | Cause and Remedy |
|---|---|
| Over Current Priority: 4 Type: Latch | Cause: Displayed when inverter output current exceeds the specified fault current. Remedy: Refer to detailed troubleshooting section in manual. |
| Ground Fault Priority: 3 Type: Latch | Cause: Displayed when a ground fault occurs in the inverter’s output, and current flow to ground exceeds the specified level. Remedy: Refer to detailed troubleshooting section in manual. |
| Over Voltage Priority: 5 Type: Latch | Cause: Displayed when the internal DC voltage exceeds the specified value (820 VDC). Remedy: Refer to detailed troubleshooting section in manual. |
| Low Voltage Priority: 9 Type: Level | Cause: Displayed when the internal DC voltage is less than the specified value (360 VDC). Remedy: Refer to detailed troubleshooting section in manual. |
| Over Load Priority: 12 Type: Latch | Cause: Displayed when the inverter’s output current exceeds the specified motor rated current and overload trip time. Remedy: Refer to detailed troubleshooting section in manual. |
| Inv OLT Priority: 16 Type: Latch | Cause: Displayed when the inverter has detected an overload and resultant overheating condition based on inverse time-limit thermal characteristics. Allowable overload rates for the inverter are 150% for 1 min. Remedy: Refer to detailed troubleshooting section in manual. |
| InvOver Heat Priority: 10 Type: Latch | Cause: Displayed when the temperature of the inverter heat sink exceeds the specified value. Remedy: Refer to detailed troubleshooting section in manual. |
| InvThem OP Priority: 19 Type: Latch | Cause: Displayed when the inverter thermistor detects a low temperature. Remedy: Refer to detailed troubleshooting section in manual. |
| MotOver Heat Priority: 18 Type: Latch | Cause: Displayed when the motor temperature exceeds 130°C. Remedy: Refer to detailed troubleshooting section in manual. |
| MotThem Err Priority: 20 Type: Latch | Cause: Displayed when a motor thermistor error occurs in the inverter thermistor. Remedy: Refer to detailed troubleshooting section in manual. |
| E-Thermal Priority: 11 Type: Latch | Cause: Displayed when internal electronic protection detects a high temperature condition at the motor. Remedy: Refer to detailed troubleshooting section in manual. |
| External-B Priority: 14 Type: Latch | Cause: Displayed when an external fault signal is generated. Remedy: Refer to detailed troubleshooting section in manual. |
| Arm Short / Arm Short-DB Priority: 1 Type: Latch | Cause: Displayed when IGBT Arm or output fault occurs. Arm Short-DB is only displayed on the 11-22 kW models. Remedy: Refer to detailed troubleshooting section in manual. |
| Fuse Open Priority: 2 Type: Latch | Cause: Displayed when circuit protection is activated by an IGBT fault. Remedy: Refer to detailed troubleshooting section in manual. |
| Encoder Err Priority: 8 Type: Latch | Cause: Displayed when an encoder signal error occurs. Remedy: Refer to detailed troubleshooting section in manual. |
| (No Display Name / General) Priority: - Type: - | Cause: Displayed when an inconsistent motor error time is detected when compared to the PRT_11 setting. Remedy: Refer to detailed troubleshooting section in manual. |
| BX Priority: - Type: Latch | Cause: Displayed when the inverter output is blocked by a signal from the multifunction terminal. Remedy: Refer to detailed troubleshooting section in manual. |
| Over Speed Priority: 21 Type: Latch | Cause: Displayed when the motor speed exceeds the specified maximum speed. Remedy: Refer to detailed troubleshooting section in manual. |
| COM Error Priority: - Type: Fatal | Cause: Displayed when communication between the inverter and the keypad is unavailable. Remedy: Refer to detailed troubleshooting section in manual. |
| HW-Diag Priority: 13 Type: Latch | Cause: Displayed when a CPU error is detected. Remedy: Refer to detailed troubleshooting section in manual. |
| EEP Error Priority: - Type: Latch | Cause: Displayed when a data saving error occurs. Remedy: Refer to detailed troubleshooting section in manual. |
| FAN Error Priority: 6 Type: Latch | Cause: Displayed when a cooling fan error is detected. Remedy: Refer to detailed troubleshooting section in manual. |
| BatRun Fault Priority: 7 Type: Latch | Cause: Displayed when operation signals are lost during a battery power operation. Remedy: Refer to detailed troubleshooting section in manual. |
| Input PO Priority: 17 Type: Latch | Cause: Displayed when a single phase of a 3-phase power supply is interrupted while the inverter is under load. Remedy: Refer to detailed troubleshooting section in manual. |
| Output PO Priority: 15 Type: Latch | Cause: Displayed when the inverter does not produce an output current. Remedy: Refer to detailed troubleshooting section in manual. |
| SpdDev Err Priority: 26 Type: Latch | Cause: Displayed when the difference between the motor speed and command speed is more than the specified value. Remedy: Refer to detailed troubleshooting section in manual. |
| Low Voltage2 Priority: 24 Type: Latch | Cause: Displayed when the internal DC voltage is less than the specified value during inverter operation. Remedy: Refer to detailed troubleshooting section in manual. |
| SAFETY A/B Priority: 25 Type: Latch/Level | Cause: Displayed when there is a safety terminal wiring fault on the control board. The response can be set at either Latch or Level. Remedy: Refer to detailed troubleshooting section in manual. |
| A3 Safety Priority: 23 Type: Latch | Cause: Displayed when an A3 Safety error is detected at a multifunction input. Remedy: Refer to detailed troubleshooting section in manual. |
| ADC Error Priority: 27 Type: Fatal | Cause: Displayed when current calibration is incorrect when power is initially supplied to the inverter. Remedy: Refer to detailed troubleshooting section in manual. |
| Flr/FHM Data Priority: 22 Type: Latch | Cause: Displayed when a floor height data error is detected or a floor height measurement failure occurs. Available only when the exclusive elevator mode is used. Remedy: Refer to detailed troubleshooting section in manual. |
| SINCOS Open Priority: 28 Type: Latch | Cause: Displayed when EnDat signals Sin-, Cos-, Sin+, and Cos+ are not connected to a single or multiple lines. Remedy: Refer to detailed troubleshooting section in manual. |
| ENDAT ERROR Priority: 29 Type: Latch | Cause: Displayed when EnDat signals for the Clock or Data lines are not connected or a communication error is detected. Remedy: Refer to detailed troubleshooting section in manual. |
How to Clear & Reset LS Electric iV5L Drive Faults
- Keypad Reset: Press the STOP/RESET key on the 32-character LCD loader keypad while the fault trip screen is displayed. Ensure the lift car is secured and elevator motion commands are halted.
- Dedicated Terminal Reset (RST): Momentarily close the contact between the dedicated RST terminal (or multi-function input configured via DIO group parameters) and the CM common terminal.
- DriveView PC Software: Connect your PC using an RS-485 serial adapter to the drive communication port, open LS DriveView, and click “Fault Reset” in the elevator status and monitor window.
- Elevator Controller / Fieldbus Network: If controlled via an upper-level elevator controller or fieldbus (CANopen, Modbus, or Profibus), issue a fault reset command bit via the communication control word.
- Mains Power Cycle: Switch off the 3-phase AC main power supply, wait at least 10 minutes until the LCD screen, internal capacitors, and charge indicator are fully discharged, and then reapply power.
⚠️ High-Voltage & Hoist Safety Warning:
Before removing terminal covers or inspecting motor/encoder connections on the LS Electric iV5L elevator inverter, ensure the elevator car is mechanically braked/secured and verify with a calibrated digital multimeter that intermediate DC bus voltage measures strictly below 30VDC across terminals [P(+)] and [N(-)].