Panasonic MINAS A6 Servo Drive Error Codes & Diagnostic Guide
Complete error code reference directory, alarm trip causes, and step-by-step diagnostic actions for the Panasonic MINAS A6 AC servo driver series (A6SE, A6SG, A6SF, A6N, and A6B). Search or filter through the complete error code table below.
Power Range
50 W – 5.0 kW (Ultra-compact)
Supply Voltage
100V / 200V / 400V AC
Control Modes
Position, Speed, Torque & Full-Closed
Setup Interface
PANATERM (USB) & 5-Key LED Display
Complete Panasonic MINAS A6 Servo Drive Error Code Directory
Use the search box in the table below to look up your code (e.g., type 12.0, 14.0, 16.0, or Overcurrent).
| ErrFault Code and Meaning error in Panasonic MINAS A6 series servo drive | ErrFault Code and Meaning error in Panasonic MINAS A6 series servo drive Cause and Remedy |
|---|---|
| Err11.0 error in Panasonic MINAS A6 series servo drive | Err11.0 Under voltage protection of control power supply error in Panasonic MINAS A6 series servo drive Cause: Voltage between P and N of converting unit of control power supply has fallen down and dropped below specified value. 1) Low power supply voltage. Occurrence of momentary power failure. 2) Power capacity shortage due to rush current at main power-on. 3) Servo driver failure (circuit failure). Remedy: Measure L1C-L2C line voltage of connector and terminal block.
|
| Err12.0 error in Panasonic MINAS A6 series servo drive | Err12.0 Over-voltage protection error in Panasonic MINAS A6 series servo drive Cause: Voltage between P and N of the converter portion of the control power supply has exceeded the specified value. 1) Power supply voltage exceeded permissible input. Surge from phase-advancing capacitor or UPS. 2) Disconnection of regeneration discharge resistor. 3) External regeneration resistor not appropriate (could not absorb energy). 4) External regeneration discharge resistor not appropriate. 5) Failure of servo driver. Remedy: Measure the voltage between lines of connector (L1, L2 and L3).
|
| Err13.0 error in Panasonic MINAS A6 series servo drive | Err13.0 Main power supply under-voltage protection (PN) error in Panasonic MINAS A6 series servo drive Cause: Instantaneous power failure occurred between L1 and L3 longer than preset time (Pr5.09) or voltage between P and N fell below specified value. 1) Power supply voltage is low / Instantaneous power failure. 2) Lack of power capacity (voltage drop due to inrush current). 3) Phase lack (3-phase driver operated with single phase). 4) Failure of servo driver. Remedy: Measure the voltage between lines of connector (L1, L2 and L3).
|
| Err13.1 error in Panasonic MINAS A6 series servo drive | Err13.1 Main power supply under-voltage protection (AC) error in Panasonic MINAS A6 series servo drive Cause: AC Power supply issues similar to 13.0 (Low voltage, phase failure, etc). Remedy:
|
| Err14.0 error in Panasonic MINAS A6 series servo drive | Err14.0 Over-current protection error in Panasonic MINAS A6 series servo drive Cause: Current through the converter portion has exceeded the specified value. 1) Failure of servo driver (IGBT or other components). 2) Short of the motor wire (U, V and W). 3) Earth fault of the motor wire. 4) Burnout of the motor. 5) Poor contact of the motor wire. 6) Welding of contact of dynamic braking relay (frequent ON/OFF). 7) Pulse input timing error. 8) Blowout of thermal fuse. 9) Power Module overheat. Remedy:
|
| Err14.1 error in Panasonic MINAS A6 series servo drive | Err14.1 IPM error protection error in Panasonic MINAS A6 series servo drive Cause: Intelligent Power Module error detected (Often associated with Over-current causes). Remedy:
|
| Err15.0 error in Panasonic MINAS A6 series servo drive | Err15.0 Over-heat protection error in Panasonic MINAS A6 series servo drive Cause: Temperature of heat sink or power device has risen over specified temperature. 1) Ambient temperature high. 2) Over-load. Remedy:
|
| Err15.1 error in Panasonic MINAS A6 series servo drive | Err15.1 Encoders abnormal Over-heat protection error in Panasonic MINAS A6 series servo drive Cause: The temperature of encoder has exceeded an encoder overheat abnormal level. 1) Ambient temperature of servomotor is high. 2) Overload. Remedy:
|
| Err16.0 error in Panasonic MINAS A6 series servo drive | Err16.0 Over-load protection error in Panasonic MINAS A6 series servo drive Cause: Torque command value exceeded over-load level (Pr5.12) for a specific time. 1) Load heavy / continuous high torque. 2) Oscillation/hunching due to poor adjustment. 3) Miswiring or disconnection. 4) Machine collision or distortion. 5) Electromagnetic brake kept engaged. 6) Miswiring multiple axes. Remedy: Check torque (current) monitor and load factor.
|
| Err16.1 error in Panasonic MINAS A6 series servo drive | Err16.1 Torque saturation anomaly protection error in Panasonic MINAS A6 series servo drive Cause: Torque saturation has continued for the time set in Pr6.57. Remedy:
|
| Err18.0 error in Panasonic MINAS A6 series servo drive | Err18.0 Over-regeneration load protection error in Panasonic MINAS A6 series servo drive Cause: Regenerative energy exceeded capacity of regenerative resistor. 1) Large load inertia / High converter voltage. 2) High motor rotational speed. 3) Active limit of external resistor limited to 10% duty. Remedy: Check load factor of regenerative resistor.
|
| Err18.1 error in Panasonic MINAS A6 series servo drive | Err18.1 Regenerative transistor error protection error in Panasonic MINAS A6 series servo drive Cause: Regenerative driver transistor on the servo driver is defective. Remedy:
|
| Err21.0 error in Panasonic MINAS A6 series servo drive | Err21.0 Encoder communication disconnection error in Panasonic MINAS A6 series servo drive Cause: Communication between encoder and driver interrupted. Remedy:
|
| Err21.1 error in Panasonic MINAS A6 series servo drive | Err21.1 Encoder communication error protection error in Panasonic MINAS A6 series servo drive Cause: Data error due to noise. Encoder cables connected but data has errors. Remedy:
|
| Err23.0 eerror in Panasonic MINAS A6 series servo drive | Err23.0 Encoder communication data error protection error in Panasonic MINAS A6 series servo drive Cause: Communication valid but data content incorrect. Mainly due to noise. Remedy:
|
| Err24.0 error in Panasonic MINAS A6 series servo drive | Err24.0 Position deviation excess protection error in Panasonic MINAS A6 series servo drive Cause: Deviation pulses exceeded Pr0.14 setup. 1) Motor movement has not followed command. 2) Setup value of Pr0.14 is small. Remedy:
|
| Err24.1 error in Panasonic MINAS A6 series servo drive | Err24.1 Speed deviation excess protection error in Panasonic MINAS A6 series servo drive Cause: Difference between internal positional command speed and actual speed exceeds Pr6.02. Remedy:
|
| Err25.0 error in Panasonic MINAS A6 series servo drive | Err25.0 Hybrid deviation excess error protection error in Panasonic MINAS A6 series servo drive Cause: Position of load (external scale) vs motor (encoder) slips larger than Pr3.28. Also caused if division/multiplication changed during full closed control. Remedy:
|
| Err26.0 error in Panasonic MINAS A6 series servo drive | Err26.0 Over-speed protection error in Panasonic MINAS A6 series servo drive Cause: Motor rotational speed exceeded setup value of Pr5.13. Remedy:
|
| Err26.1 error in Panasonic MINAS A6 series servo drive | Err26.1 2nd Over-speed protection error in Panasonic MINAS A6 series servo drive Cause: Motor rotational speed exceeded setup value of Pr6.15. Remedy:
|
| Err27.0 error in Panasonic MINAS A6 series servo drive | Err27.0 Command pulse input frequency error error in Panasonic MINAS A6 series servo drive Cause: Frequency of command pulse input is more than 1.2 times the setting in Pr5.32. Remedy:
|
| Err27.1 error in Panasonic MINAS A6 series servo drive | Err27.1 Absolute clear abnormal protection error in Panasonic MINAS A6 series servo drive Cause: Absolute encode multi-rotation clear executed when block operation was enabled (Pr 6.28 is not 0). Remedy:
|
| Err27.2 error in Panasonic MINAS A6 series servo drive | Err27.2 Command pulse multiplier error error in Panasonic MINAS A6 series servo drive Cause: Division/Multiplication ratio settings (electronic gear) not appropriate. Calculated pulses exceed 3000 Mpps. Noise on command pulse. Backlash correction error. Remedy:
|
| Err28.0 error in Panasonic MINAS A6 series servo drive | Err28.0 Limit of pulse replay protection error in Panasonic MINAS A6 series servo drive Cause: The output frequency of pulse regeneration has exceeded the limit. Remedy:
|
| Err29.0 error in Panasonic MINAS A6 series servo drive | Err29.0 Deviation counter overflow protection error in Panasonic MINAS A6 series servo drive Cause: Position deviation value of encoder pulse standard exceeded 2^30-1. Remedy:
|
| Err29.1 error in Panasonic MINAS A6 series servo drive | Err29.1 Counter overflow error protection 1 error in Panasonic MINAS A6 series servo drive Cause: Value of absolute encoder position/electronic gear ratio exceeded limit during initialization. Remedy:
|
| Err29.2 error in Panasonic MINAS A6 series servo drive | Err29.2 Counter overflow error protection 2 error in Panasonic MINAS A6 series servo drive Cause: Value of positioning deviation has exceeded limit in pulse units or command units. Remedy:
|
| Err31.0 error in Panasonic MINAS A6 series servo drive | Err31.0 Safety function error protection error in Panasonic MINAS A6 series servo drive Cause: Safety function has detected an error. Remedy:
|
| Err33.0 error in Panasonic MINAS A6 series servo drive | Err33.0 - Err33.7 I/F overlap allocation / Input function errors error in Panasonic MINAS A6 series servo drive Cause: 33.0: Input signals (SI1-SI5) assigned with two functions. 33.1: Input signals (SI6-SI10) assigned with two functions. 33.2: Input signals (SI1-SI5) assigned with undefined number. 33.3: Input signals (SI6-SI10) assigned with undefined number. 33.4: Output signals (SO1-SO3) assigned with undefined number. 33.5: Output signals (SO4-SO6) assigned with undefined number. 33.6: Counter clear assigned to signal other than SI7. 33.7: Command pulse inhibit assigned to signal other than SI10. Remedy:
|
| Err34.0 error in Panasonic MINAS A6 series servo drive | Err34.0 Motor working range setup error protection error in Panasonic MINAS A6 series servo drive Cause: Motor exceeded working range set to Pr5.14. Remedy:
|
| Err36.0 / Err36.1 error in Panasonic MINAS A6 series servo drive | Err36.0 / Err36.1 EEPROM parameter error protection error in Panasonic MINAS A6 series servo drive Cause: Data in parameter storage area damaged when reading from EEPROM at power-on. Remedy:
|
| Err37.0 / Err37.1 / Err37.2 error in Panasonic MINAS A6 series servo drive | Err37.0 / Err37.1 / Err37.2 EEPROM check code error protection error in Panasonic MINAS A6 series servo drive Cause: Data for writing confirmation to EEPROM has been damaged. Remedy:
|
| Err38.0 error in Panasonic MINAS A6 series servo drive | Err38.0 Drive prohibition input protection error in Panasonic MINAS A6 series servo drive Cause: Both positive and negative direction drive prohibition inputs (POT and NOT) have been turned ON at Pr5.04 “Over-travel inhibition input setting” =0. Either positive direction drive prohibition input or negative direction drive prohibition input has been turned ON at Pr5.04=2. Remedy: Check that there is no error in the switches, wires and power supply connected to the positive direction/negative direction drive prohibition input. Check particularly that start-up of the power supply for the control signal (DC12 to 24 V) is not slow. |
| Err39.0 error in Panasonic MINAS A6 series servo drive | Err39.0 Analog input 1 (AI1) excess protection error in Panasonic MINAS A6 series servo drive Cause: The voltage more than the value set in Pr4.24 “Analog input 1 (AI1) excess setup” has been applied to analog input 1. Remedy:
|
| Err39.1 error in Panasonic MINAS A6 series servo drive | Err39.1 Analog input 2 (AI2) excess protection error in Panasonic MINAS A6 series servo drive Cause: The voltage more than the value set in Pr4.27 “Analog input 2 (AI2) excess setup” has been applied to analog input 2. Remedy:
|
| Err39.2 error in Panasonic MINAS A6 series servo drive | Err39.2 Analog input 3 (AI3) excess protection error in Panasonic MINAS A6 series servo drive Cause: The voltage more than the value set in Pr4.30 “Analog input 3 (AI3) excess setup” has been applied to analog input 3. Remedy:
|
| Err40.0 error in Panasonic MINAS A6 series servo drive | Err40.0 Absolute system down error protection error in Panasonic MINAS A6 series servo drive Cause: The power supplies and battery powers to absolute encoder were shut down, and the built-in capacitor voltage dropped below specified value. Caution: Once this error occurs, the alarm cannot be cleared until the absolute encoder is reset. Remedy: After connecting the power supply for the battery, clear the absolute encoder.
|
| Err41.0 error in Panasonic MINAS A6 series servo drive | Err41.0 Absolute counter over error protection error in Panasonic MINAS A6 series servo drive Cause: Multi-turn counter of the absolute encoder has exceeded the specified value. Remedy:
|
| Err42.0 error in Panasonic MINAS A6 series servo drive | Err42.0 Absolute over-speed error protection error in Panasonic MINAS A6 series servo drive Cause: When using absolute encoder: 1) During a power failure, when only battery power is supplied, the motor rotational speed has exceeded the specified value. 2) During normal operation, for some reason, the power of encoder has been shut down, and the rotational speed has exceeded the specified value. Caution: Once this error occurs, the alarm cannot be cleared until the absolute encoder is reset. Remedy: 1) Check the external driving force for motor and the rotational speed at the time, and operate to make the speed below specified value. 2) The mode was switched to a power failure mode during normal operation. Check the power supply voltage of encoder side (5V±5 %). Check the connection of connector X6. |
| Err44.0 error in Panasonic MINAS A6 series servo drive | Err44.0 Absolute single turn counter error / Incremental single turn counter error error in Panasonic MINAS A6 series servo drive Cause: Absolute encoder has detected a single turn counter error. Serial incremental encoder has detected an error in the incremental counter value of single turn counter (between z-phase signals). Remedy: Replace the motor. |
| Err45.0 error in Panasonic MINAS A6 series servo drive | Err45.0 Absolute multi-turn counter error / Incremental counter error error in Panasonic MINAS A6 series servo drive Cause: Absolute encoder has detected a multi-turn counter error. Serial incremental encoder has detected an error in the incremental counter values between CS signals. Remedy: Replace the motor. If you use the incremental system, check if Pr 0.15 "sets the absolute encoder" is set to 1. |
| Err47.0 error in Panasonic MINAS A6 series servo drive | Err47.0 Absolute status error protection error in Panasonic MINAS A6 series servo drive Cause: When power is turned on, absolute encoder has been rotated at the specified value or above. Remedy: Arrange so as the motor does not run at power-on. |
| Err50.0 error in Panasonic MINAS A6 series servo drive | Err50.0 External scale wiring error protection error in Panasonic MINAS A6 series servo drive Cause: Communication between the external scale and the driver has been interrupted in certain times, and disconnection detecting function has been triggered. Remedy:
|
| Err50.1 error in Panasonic MINAS A6 series servo drive | Err50.1 External scale communication data error protection error in Panasonic MINAS A6 series servo drive Cause: Communication error has occurred in data from the external scale. Mainly data error due to noise. External scale cables are connected, but communication date has some error. Remedy:
|
| Err50.2 error in Panasonic MINAS A6 series servo drive | Err50.2 External displacement sensor communication data error protection error in Panasonic MINAS A6 series servo drive Cause: External displacement sensor communication has no error, but error occurred in data. External displacement sensor communication data error mainly due to noise. Remedy: Connect the shield to FG (refer to wiring diagram). |
| Err51.0 error in Panasonic MINAS A6 series servo drive | Err51.0 External scale status 0 error protection error in Panasonic MINAS A6 series servo drive Cause: Bit 0 of the external scale error code (ALMC) has been turned to 1. Check the specifications of the external scale. Remedy: Remove the causes of the error, then clear the external scale error from the front panel. And then, shut off the power to reset. |
| Err51.1 error in Panasonic MINAS A6 series servo drive | Err51.1 External scale status 1 error protection error in Panasonic MINAS A6 series servo drive Cause: Bit 1 of the external scale error code (ALMC) has been turned to 1. Check the specifications of the external scale. Remedy: (Same as above) Remove causes, clear error, shut off power to reset. |
| Err51.2 error in Panasonic MINAS A6 series servo drive | Err51.2 External scale status 2 error protection error in Panasonic MINAS A6 series servo drive Cause: Bit 2 of the external scale error code (ALMC) has been turned to 1. Check the specifications of the external scale. Remedy: Remove the causes of the error, then clear the external scale error from the front panel. And then, shut off the power to reset. |
| Err51.3 error in Panasonic MINAS A6 series servo drive | Err51.3 External scale status 3 error protection error in Panasonic MINAS A6 series servo drive Cause: Bit 3 of the external scale error code (ALMC) has been turned to 1. Check the specifications of the external scale. Remedy: (Refer to general external scale error handling). |
| Err51.4 error in Panasonic MINAS A6 series servo drive | Err51.4 External scale status 4 error protection error in Panasonic MINAS A6 series servo drive Cause: Bit 4 of the external scale error code (ALMC) has been turned to 1. Check the specifications of the external scale. Remedy: (Refer to general external scale error handling). |
| Err51.5 error in Panasonic MINAS A6 series servo drive | Err51.5 External scale status 5 error protection error in Panasonic MINAS A6 series servo drive Cause: Bit 5 of the external scale error code (ALMC) has been turned to 1. Check the specifications of the external scale. Remedy: Remove the causes of the error, then clear the external scale error from the front panel. And then, shut off the power to reset. |
| Err55.0 .error in Panasonic MINAS A6 series servo drive | Err55.0 A-phase wiring error protection error in Panasonic MINAS A6 series servo drive Cause: A-phase wiring in the external scale is defective, e.g. discontinued. Remedy: When using serial communication type external displacement sensor, please change the setting value of Pr3.23 external displacement sensor type selection to: 1 : serial communication type(incremental specification) or 2 : serial communication type(absolute specification). |
| Err55.1 error in Panasonic MINAS A6 series servo drive | Err55.1 B-phase wiring error protection error in Panasonic MINAS A6 series servo drive Cause: B-phase wiring in the external scale is defective, e.g. discontinued. Remedy: (Same as above) Change setting value of Pr3.23. |
| Err55.2 error in Panasonic MINAS A6 series servo drive | Err55.2 Z-phase wiring error protection error in Panasonic MINAS A6 series servo drive Cause: Z-phase wiring in the external scale is defective, e.g. discontinued. Remedy: (Same as above) Change setting value of Pr3.23. |
| Err70.0 error in Panasonic MINAS A6 series servo drive | Err70.0 U-phase current detector error protection error in Panasonic MINAS A6 series servo drive Cause: U-phase current offset error is detected. Remedy:
|
| Err70.1 error in Panasonic MINAS A6 series servo drive | Err70.1 W-phase current detector error protection error in Panasonic MINAS A6 series servo drive Cause: W-phase current offset error is detected. Remedy: (Same as U-phase error) Turn off power, re-enter. If repeats, replace unit. |
| Err71.0 error in Panasonic MINAS A6 series servo drive | Err71.0 CCWTL anomaly protection error in Panasonic MINAS A6 series servo drive Cause: 11 V or more at analog input 2 or -11 V or less was applied. Remedy: Check the connection status of the I/F connector. Turn the power off and then on again. |
| Err71.1 error in Panasonic MINAS A6 series servo drive | Err71.1 CWTL anomaly protection error in Panasonic MINAS A6 series servo drive Cause: 11 V or more at analog input 3 or -11 V or less applied. Remedy: Check the connection status of the I/F connector. Turn the power off and then on again. |
| Err72.0 error in Panasonic MINAS A6 series servo drive | Err72.0 Thermal error protection error in Panasonic MINAS A6 series servo drive Cause: Thermal protector error is detected. Remedy: Check motor temperature and wiring. |
| Err80.0 error in Panasonic MINAS A6 series servo drive | Err80.0 Modbus communication timeout protection error in Panasonic MINAS A6 series servo drive Cause: While ensuring Modbus execution right, Modbus communication against own axis has not been received for more than the set time. Remedy:
|
| Err87.0 error in Panasonic MINAS A6 series servo drive | Err87.0 Forced alarm input protection error in Panasonic MINAS A6 series servo drive Cause: Forced alarm input (E-STOP) is applied. Remedy: Check the wiring of forced alarm input (E-STOP). |
| Err92.0 error in Panasonic MINAS A6 series servo drive | Err92.0 Encoder data recovery abnormal protection error in Panasonic MINAS A6 series servo drive Cause: Initialization process of internal position information has not conducted normally under absolute and semi-closed control mode. Remedy:
|
| Err92.1 error in Panasonic MINAS A6 series servo drive | Err92.1 External scale data recovery error protection error in Panasonic MINAS A6 series servo drive Cause: Internal position information initialization error under full-closed control and absolute mode with block operation enabled. Remedy:
|
| Err92.3 error in Panasonic MINAS A6 series servo drive | Err92.3 Multi-rotation upper limit value inconsistency error protection error in Panasonic MINAS A6 series servo drive Cause: At continuous rotating absolute encoder function, there was a disagreement between the upper-limit value of encoder multi-turn data and the upper-limit value of driver parameter multi-turn data. Remedy:
|
| Err93.0 error in Panasonic MINAS A6 series servo drive | Err93.0 Parameter setup error 1 error in Panasonic MINAS A6 series servo drive Cause: 1) Electronic gear ratio exceeds the allowable range. 2) When a block operation was enabled(Pr 6.28 is non 0), Modbus connection was disabled (Pr 5.37 is 0). 3) When the backlash correction function is enabled (Pr 7.04 = bit 1 - 0 is other than 0) and no block operation is performed (Pr 6.28 = 0), the value of Pr 7.18 "backlash correction amount holding range" converted to pulse units by the electronic gear ratio exceeds 2147483647. Remedy: Check the setting value of the parameter. 1) When a block operation was enabled (Pr 6.28 is non 0), Electronic gear ratio must be in the range 1/1000 to 8000. 2) When a block operation was enabled (Pr 6.28 is non 0), Modbus connection was disabled (Pr 5.37 is 0). 3) Check the setting of Pr 7.18 "Retention range of backlash compensation" and electronic gear ratio. |
| Err93.1 error in Panasonic MINAS A6 series servo drive | Err93.1 Block data setting error protection error in Panasonic MINAS A6 series servo drive Cause: 1) The blocking action was activated by setting the velocity, acceleration and deceleration to 0 or by setting the acceleration and deceleration to values exceeding 4294967295 [command unit/s²]. 2) The conditional branch command does not correspond to the comparison target. 3) The command for the specified block data is not defined. 4) In addition, there is an error in the block data setting. Remedy: 1) Check speed, acceleration and deceleration values. 2) Check if there are any problems with the conditional branch command or comparison target. 3) Check if there are any problems with the block data. Check if there are any problems with the block number specification. 4) Check if there are any problems with the block data setting. |
| Err93.2 error in Panasonic MINAS A6 series servo drive | Err93.2 Parameter setting error protection 2 error in Panasonic MINAS A6 series servo drive Cause: External scale ratio has exceeded the allowable range (1/160000 to 160000 times). Remedy:
|
| Err93.3 error in Panasonic MINAS A6 series servo drive | Err93.3 External scale connection error protection error in Panasonic MINAS A6 series servo drive Cause: Set value for Pr3.23 “External scale type selection” and the connected serial communication type external scale type to not match. Remedy: Set Pr3.23 to match the type of the connected external scale. |
| Err94.0 error in Panasonic MINAS A6 series servo drive | Err94.0 Block operation error protection error in Panasonic MINAS A6 series servo drive Cause: 1) During the execution of movement system command (During the execution of position command creation process), a new movement system command has been executed. 2) During block operation, a new block number was designated to start. 3) Although it was servo-off, a block operation was started. Remedy: 1) Check whether the block operation sequence does not have any problems. 2) Check whether the host sequence does not have any problems. 3) Check whether the host sequence does not have any problems. |
| Err94.2 error in Panasonic MINAS A6 series servo drive | Err94.2 Return to origin error protection error in Panasonic MINAS A6 series servo drive Cause: 1) Return to origin command of block operation was executed in the absolute mode. 2) In the return to origin operation of the block operation, the prohibited driving input in the return to origin direction was turned ON, and the prohibited driving input in the opposite direction to the return to origin direction was turned ON during the reverse operation. 3) In the return to origin operation of the block operation, both POT and NOT of the driving prohibited input were turned on. 4) Relative or absolute positioning was performed in the uncompleted return to origin state. Remedy: 1) Check the block data setting or the absolute mode setting for any problems. 2) Check if there are any problems in the arrangement relation between the driving prohibited input and the origin (Sensor input, Z-phase). 3) Check if there are any problems in the arrangement relation between the driving prohibited input. 4) Check if there are any problems in the block data setting. |
| Err95.0 error in Panasonic MINAS A6 series servo drive | Err95.0 to 4 Motor automatic recognition error protection error in Panasonic MINAS A6 series servo drive Cause: The motor and the driver has not been matched. Remedy: Replace the motor which matches to the driver. |
| Err96.2 error in Panasonic MINAS A6 series servo drive | Err96.2 Control unit error protection 1 error in Panasonic MINAS A6 series servo drive Cause: Control circuit has malfunctioned due to excess noise or other causes. Some error has occurred inside of the driver, which triggered self-diagnosis function of the driver. Remedy: Turn off power once, and turn on again. Even so, if an error indication appears, failure is possible. Discontinue to use and replace the motor and servo driver. Return to a dealer for investigation(repair). |
| Err97.0 error in Panasonic MINAS A6 series servo drive | Err97.0 Control mode setting error protection error in Panasonic MINAS A6 series servo drive Cause: 1) Block operation was enabled except for position control (Pr 0.01 = 0) or full close control (Pr 0.01 = 6). 2) When Pr 6.28 "Special function setting" = 4 (block operation enabled by starting input signal) was set, Pr 0.15 "Absolute encoder setting" = 1 (increment mode) was set. Remedy: 1) Check the settings of Pr 0.01 "Control mode setting" and Pr 6.28 "Special function selection." 2) Check the settings of Pr 6.28 "Special function setting" and Pr 0.15 "Absolute encoder setting." |
How to Clear & Reset Panasonic MINAS A6 Drive Errors
- Front Panel Button Reset: On the driver front panel, navigate to the error display mode using the [MODE] button, then press and hold the [SET] button for approximately 3 seconds until the display clears.
- Digital Input Signal (A-CLR): Turn ON the Alarm Clear input terminal (A-CLR) by applying a continuous signal for at least 120 ms. Ensure the servo-off condition is established before asserting the clear signal.
- PANATERM Setup Software: Connect a PC using a standard mini-USB cable to connector X1, open the PANATERM support tool, navigate to the Alarm screen, and click “Alarm Clear”.
- Communication Command: If operating via EtherCAT (A6B) or RTEX (A6N), transmit the fault reset control command word via the master PLC or network motion controller.
- Control Power Cycle: Critical non-resettable alarms (such as Err 12.0 Overcurrent, Err 13.0 Main Power Undervoltage, or Err 14.0 Overvoltage) cannot be cleared via software or digital inputs. Turn OFF control power (L1C, L2C) and main power (L1, L2, L3), wait for the front-panel CHARGE LED to fully turn off, resolve the mechanical or wiring cause, and reapply power.
⚠️ High-Voltage Electrical Safety Warning:
Before disconnecting motor leads, checking regenerative resistor connections, or touching power terminals (L1, L2, L3, P, B, N, U, V, W), disconnect all incoming electrical power and confirm that the red CHARGE LED has completely turned off. Always measure with a calibrated voltmeter to verify DC intermediate bus voltage is safely below 50VDC.