Delta ASDA-B Servo Drive Fault Codes & Diagnostic Guide

Complete alarm code reference directory, trip error causes, and field troubleshooting procedures for the Delta ASDA-B standard AC servo drive series. Search or filter through the complete alarm directory below.

Standard General-Purpose AC Servo Power: 100 W to 2.0 kW (0.1 to 2.0 kW) 2500 ppr Incremental Encoder & Dual Modes
Power Range 0.1 – 2.0 kW (100W – 2 kW)
Supply Voltage 200–230V AC (1-Ph / 3-Ph)
Control Modes Position (PT), Speed, & Torque
Operator Interface 5-Digit 7-Segment Display / ASDA-Soft

Complete Delta ASDA-B Servo Drive Fault Code Directory

Use the search box in the table below to quickly find your alarm code (e.g., type AL001, AL003, AL009, or Overcurrent).

Fault Code and MeaningCause and Remedy
ALE 1

Overcurrent

Cause:

Short-circuit at drive output (U, V, W), Motor wiring error, IGBT error, or Heat sink overheated.



Remedy:


  • Check wiring connections between drive and motor for short circuits.

  • Repair short-circuited wires and avoid exposed metal conductors.

  • Follow wiring steps in the user manual to reconnect wiring.

  • If heat sink is overheated or hardware is damaged, contact distributor or Delta.


ALE 2

Overvoltage

Cause:

Main circuit voltage exceeded maximum allowable value, Power input error (incorrect input), or Servo drive hardware damage.



Remedy:


  • Use voltmeter to check if input voltage is within rated specifications (refer to manual section 11.1).

  • Use correct power supply or stabilizing power.

  • If hardware is damaged after voltage check, contact distributor or Delta.


ALE 3

Undervoltage

Cause:

Main circuit voltage below minimum value, No input voltage at main circuit, Power input error, or Hardware damage.



Remedy:


  • Check if main circuit input voltage wiring is correct.

  • Reconfirm power supply and switches; ensure input voltage is normal.

  • Use correct power supply or stabilizing power.

  • Contact distributor or Delta if hardware is damaged.


ALE 4

Z Pulse shift

Cause:

Encoder is damaged or Encoder is loose.



Remedy:


  • Check Encoder for damage; repair or replace the motor.

  • Examine Encoder connector; install the motor again.


ALE 5

Regeneration error

Cause:

Regenerative resistor not connected, Transistor for regeneration disabled/short-circuited, Parameter setting error, or Hardware damage.



Remedy:


  • Check wiring connection of regenerative resistor and reconnect if necessary.

  • Confirm parameter setting and specifications of regenerative resistor; reset parameter.

  • If transistor is short-circuited or hardware damaged, contact distributor or Delta.


ALE 6

Overload

Cause:

Drive exceeded rated load, Control system parameter incorrect (Gain/Accel/Decel), Wiring error, Encoder damaged, or Incorrect U, V, W connection.



Remedy:


  • Check if drive is overloaded; increase motor capacity or reduce load.

  • Adjust gain value of control circuit if mechanical vibration exists.

  • Decrease Accel/Decel time setting.

  • Ensure all wiring (U, V, W and encoder) is correct.

  • Contact distributor if encoder is damaged.


ALE 7

Overspeed

Cause:

Wiring of motor incorrect, Encoder damaged, Speed input command unstable, or Over-speed parameter setting defective.



Remedy:


  • Ensure all wiring of U, V, W and encoder is correct.

  • Ensure input command frequency is stable; activate filter function (P1-06, P1-07, P1-08).

  • Correctly set over-speed parameter setting (P2-34).

  • Contact distributor if encoder is damaged.


ALE 8

Abnormal pulse control command

Cause:

Pulse command frequency is higher than rated input frequency.



Remedy:


  • Use pulse frequency detector to measure input frequency.

  • Correctly set the input pulse frequency.


ALE 9

Excessive deviation

Cause:

Maximum deviation parameter too small, Torque limit too low, Overload, Gain value too small, or Too much fluctuation of pulse command.



Remedy:


  • Increase the parameter setting value of P2-35.

  • Correctly adjust torque limit value.

  • Correctly adjust gain value.

  • Reduce external applied load or re-estimate motor capacity.

  • Adjust pulse frequency and activate filter function (P1-06, P1-07, P1-08).


ALE 10

Serial communication error

Cause:

Communication parameter setting defective, Communication address incorrect, or Communication value incorrect.



Remedy:


  • Check and correctly set communication parameter settings.

  • Check and correctly set communication address.

  • Check and correctly set communication value.


ALE 11

Encoder error (Position detector fault)

Cause:

Wiring of encoder in error/defective, Encoder is loose, or Encoder is damaged.



Remedy:


  • Check if all wiring is correct according to user manual.

  • Check if connections are tight and conduct wiring again.

  • Examine encoder connector and install motor again.

  • If encoder is damaged, repair or replace the motor.


ALE 12

Adjustment error

Cause:

Motor is running during adjustment, Analog input contact does not return to zero, or Detection device damaged.



Remedy:


  • Turn off the motor.

  • Measure voltage level of analog input; correctly ground analog input contact.

  • Check and reset the power supply.

  • Contact distributor if detection device is damaged.


ALE 13

Emergency stop activated

Cause:

Emergency stop switch is activated.



Remedy:


  • Check if emergency stop switch is On or Off.

  • Activate (reset) emergency stop switch.


ALE 14

Reverse (CWL) limit switch error

Cause:

Reverse limit switch is activated or Servo system is not stable.



Remedy:


  • Check if reverse limit switch is On or Off; activate switch.

  • Check control parameter setting and load inertia.

  • Modify parameter setting and re-estimate motor capacity.


ALE 15

Forward (CCWL) limit switch error

Cause:

Forward limit switch is activated or Servo system is not stable.



Remedy:


  • Check if forward limit switch is On or Off; activate switch.

  • Check control parameter setting and load inertia.

  • Modify parameter setting and re-estimate motor capacity.


ALE 16
IGBT temperature error

Cause: The drive has exceeded its rated load during continuous operation. (Check: Check if there is overload or the motor current is too high).



Remedy:

  • Increase motor capacity or reduce load.





Cause: Short-circuit at drive output. (Check: Check the drive input wiring).



Remedy:

  • Ensure all wiring is correct.


ALE 17
Memory error

Cause: Data error in Memory read-out / write-in. (Check: Reset parameter or power supply).



Remedy:

  • Please contact your distributor for assistance or contact with Delta.


ALE 18
Serial communication time out

Cause: Setting value in time out parameter is not correct. (Check: Check communication time out parameter setting).



Remedy:

  • Correctly set P3-07.





Cause: Not receiving communication command for a long time. (Check: Check whether communication cable is loose or broken).



Remedy:

  • Tighten the communication cable.

  • Make sure the communication cable is not damaged.

  • Ensure all wiring is correct.


ALE 19
Motor type error

Cause: Servo drive and servo motor do not match. (Check: Check the type of servo drive and servo motor and their combination).



Remedy:

  • Replace the servo drive or replace the servo motor.


ALE 20
Input power phase loss

Cause: Control power supply is in error. (Check: Check the power cable and connections of R, S, T. Check whether the power cable is loose or the possible loss of phase on input power).



Remedy:

  • If the fault does not clear even when the three-phase power is connected correctly, please contact your distributor for assistance or contact with Delta.


ALE 30
LCM hardware error

Cause: No display. (Check: Check if the 4th Pin of LCM is normal).



Remedy:

  • Please contact your distributor for assistance or contact with Delta.





Cause: Error characters display. (Check: Check if the related Pins are short-circuited and check if IC operation is normal).



Remedy:

  • Please contact your distributor for assistance or contact with Delta.


ALE 31
LED hardware error

Cause: LED indicator is abnormal. (Check: Check if LED is normal. Check if the transistor is abnormal and check if IC operation is normal by setting P8-09 to 2).



Remedy:

  • Please contact your distributor for assistance or contact with Delta.


ALE 32
KEY hardware error

Cause: The function key is disabled. (Check: Check if IC operation is normal by setting P8-09 to 1).



Remedy:

  • Activate P8-09 to perform the testing.

  • Please contact your distributor for assistance or contact with Delta.


ALE 33
RAM hardware error

Cause: LCM display is abnormal (disorganized display). (Check: Please check if the working voltage of RAM is normal).



Remedy:

  • Activate P8-09 to perform the testing.

  • Please contact your distributor for assistance or contact with Delta.





Cause: Function key is abnormal. (Check: Check if the transistor is abnormal and check if IC operation is normal by setting P8-09 to 3).



Remedy:

  • Activate P8-09 to perform the testing.

  • Please contact your distributor for assistance or contact with Delta.


ALE 34
EEPROM hardware error

Cause: Store data error. (Check: Check if the operation of MCU or EEPROM is normal by setting P8-09 to 4).



Remedy:

  • Activate P8-09 to perform the testing.

  • Please contact your distributor for assistance or contact with Delta.


ALE 35
COMM hardware error

Cause: Hardware error. (Check: Check if the serial communication signal is normal).



Remedy:

  • Activate P8-09 to perform the testing.

  • Please contact your distributor for assistance or contact with Delta.





Cause: Communication parameter setting is defective. (Check: Check the communication parameter setting).



Remedy:

  • Correctly set parameter setting.


ALE 40
Initial setup error

Cause: Communication error occurs when initial setup. (Check: Communication initial setup has not completed yet. Please check if the communication serial signal is normal).



Remedy:

  • Correctly set communication parameter setting.

  • Please contact your distributor for assistance or contact with Delta.





Cause: Parameter read error when initial setup. (Check: EEPROM cannot read normally. Set P8-09 to 4 to test EEPROM and check if EEPROM is normal).



Remedy:

  • Activate P8-09 to perform the testing.

  • Please contact your distributor for assistance or contact with Delta.





Cause: Communication mode is error. (Check: Check if using ASDA series servo drive).



Remedy:

  • Please use ASDA series servo drive.


ALE 41
Communication receive time out

Cause: Not receiving communication data for a long time. (Check: Check if the communication cable is loose or broken).



Remedy:

  • Ensure all wiring is correct.

  • Please contact your distributor for assistance or contact with Delta.





Cause: Data receiving is not completed. (Check: Check if the serial communication signal is normal).



Remedy:

  • Please contact your distributor for assistance or contact with Delta.


ALE 42
Communication receive error

Cause: Checksum error. (Check: Check if the checksum of the receiving data is correct).



Remedy:

  • Verify the sending and receiving data format.

  • Please contact your distributor for assistance or contact with Delta.





Cause: Checksum error. (Check: Check the communication quality).



Remedy:

  • Please contact your distributor for assistance or contact with Delta.


ALE 43
Error communication response address

Cause: Receive the error communication response address. (Check: Check if the sending and receiving communication address are the same).



Remedy:

  • Check if the communication setting is correct by using P8-05.

  • Verify the sending and receiving data format.


ALE 44
Error communication response command

Cause: Respond the error communication command. (Check: Respond the error Modbus command).



Remedy:

  • Verify the sending and receiving data format.


ALE 45
Communication parameter address error

Cause: Respond the error parameter address. (Check: Check if the sending and receiving communication code are the same).



Remedy:

  • Verify the sending and receiving data format.


ALE 46
Communication parameter content error

Cause: Respond error parameter content when reading parameter. (Check: The data length of the content is error).



Remedy:

  • Verify the sending and receiving data format.





Cause: Respond error parameter content when writing parameter. (Check: The data content is in error).



Remedy:

  • Verify the sending and receiving data format.


ALE 47
Drive specification error

Cause: Parameter SAVE operation is in error. (Check: Use P8-13 to check if the specification stored in the memory block match the actual servo drive specification when executing SAVE function).



Remedy:

  • Select the unused memory block to save the parameter.

  • Delete the memory block.





Cause: Parameter WRITE operation is in error. (Check: Use P8-13 to check if the specification stored in the memory block match the actual servo drive specification when executing WRITE function).



Remedy:

  • Select the correct memory block.


ALE 48
Fast editing function error

Cause: The function of static and auto-tuning is in error. (Check: The setting of P2-32 is incorrect).



Remedy:

  • Set P2-32 to Manual mode.





Cause: The function of dynamic auto-tuning is in error. (Check: Execution time out or the function is not executed completely).



Remedy:

  • Please contact your distributor for assistance or contact with Delta.


How to Clear & Reset Delta ASDA-B Servo Drive Faults

  1. Keypad Reset: Once the root cause of the error is resolved, press and hold the SHIFT / ENTER key on the front 5-digit LED keypad panel to reset clearable alarm codes.
  2. Digital Input Reset (ARST): Pulse the multi-function digital input assigned to ARST (Alarm Reset) (Function code 0x02 assigned to DI1–DI4 via parameters P2-10 to P2-13).
  3. ASDA-Soft PC Tool: Connect your computer through the serial communication port (RS-232 / RS-485), open ASDA-Soft, navigate to the diagnostic/status monitor, and select “Alarm Reset”.
  4. Factory Parameter Restoration: To reinitialize all parameters back to default settings, access parameter P2-08 and set it to 10 (or 1), then execute a power cycle.
  5. Complete AC Power Cycle: Disconnect incoming mains AC supply power (terminals R, S, T / L1, L2), wait until the 5-digit LED screen and red CHARGE LED turn completely off (approx. 5 minutes for capacitor discharge), then reconnect power.
⚠️ High-Voltage Electrical Safety Warning: Hazardous electrical energy remains stored in intermediate DC bus capacitors even after mains power is disconnected. Always wait until the red CHARGE LED turns completely OFF, and verify with a calibrated multimeter that DC bus voltage across terminals P⊕ and D/C measures below 25VDC before touching terminals or servicing servo motor phase leads (U, V, W).