Delta VFD-F Drive Fault Codes & Diagnostic Guide
Complete fault code reference directory, trip alarm causes, and field troubleshooting guidelines for the Delta VFD-F dedicated fan and pump AC drive series. Search or filter through the complete fault code list below.
Power Range
0.75 – 220 kW (1 – 300 HP)
Supply Voltage
230V / 460V AC (3-Phase)
Control Modes
V/F Control (Adjustable & Energy-Saving)
Operator Interface
Digital Keypad with Display
Complete Delta VFD-F Drive Fault Code Directory
Use the search box in the table below to quickly find your error code (e.g., type ocA, ovn, GFF, or EF).
| Fault Code and Meaning | Cause and Remedy |
|---|---|
| oc Over Current | Cause: The AC drive detects an abnormal increase in current. Remedy:
|
| ou Over Voltage | Cause: The AC drive detects that the DC bus voltage has exceeded its maximum allowable value. Remedy:
|
| oH Over Heat | Cause: The AC drive temperature sensor detects excessive heat. Remedy:
|
| Lu Low Voltage | Cause: The AC drive detects that the DC bus voltage has fallen below its minimum value. Remedy:
|
| oL Over Load | Cause: The AC drive detects excessive drive output current. Note: The AC drive can withstand up to 150% of the rated current for a maximum of 60 seconds. Remedy:
|
| oL1 Internal electronic overload trip | Cause: Internal electronic overload trip. Remedy:
|
| oL2 Motor Overload | Cause: Motor overload. Check the parameter settings (Pr.6-03 to Pr.6-05). Remedy:
|
| HPF1 GFF hardware error | Cause: GFF hardware error. Remedy:
|
| HPF2 CC (Current Clamp) | Cause: CC (Current Clamp) error. Remedy:
|
| HPF3 OC hardware error | Cause: OC hardware error. Remedy:
|
| HPF4 OV hardware error | Cause: OV hardware error. Remedy:
|
| HPF5 OH hardware error | Cause: OH hardware error. Remedy:
|
| cE-- Communication Error | Cause: Communication Error. Remedy:
|
| ocA Over-current during acceleration | Cause: 1. Short-circuit at motor output. 2. Torque boost too high. 3. Acceleration time too short. 4. AC drive output capacity is too small. Remedy:
|
| ocd Over-current during deceleration | Cause: 1. Short-circuit at motor output. 2. Deceleration time too short. 3. AC drive output capacity is too small. Remedy:
|
| ocn Over-current during steady state | Cause: 1. Short-circuit at motor output. 2. Sudden increase in motor loading. 3. AC drive output capacity is too small. Remedy:
|
| EF Analog Signal Error | Cause: Analog Signal Error. Remedy:
|
| EF1 Emergency stop | Cause: When the multi-function input terminals (MI1 to MI8) stop, AC drive stops any output. Remedy:
|
| cF1 Internal memory error | Cause: Internal memory IC cannot be programmed. Remedy:
|
| cF2 Internal memory error | Cause: Internal memory IC cannot be read. Remedy:
|
| cF3.3 U-phase error | Cause: U-phase error. Remedy:
|
| cF3.4 V-phase error | Cause: V-phase error. Remedy:
|
| cF3.5 W-phase error | Cause: W-phase error. Remedy:
|
| cF3.6 OV or LV | Cause: OV or LV (Over Voltage or Low Voltage) error. Remedy:
|
| cF3.7 Isum error | Cause: Isum error. Remedy:
|
| cF3.8 OH error | Cause: OH (Over Heat) error. Remedy:
|
| codE Software protection failure | Cause: Software protection failure. Remedy:
|
| cFA Auto accel/decel failure | Cause: Auto accel/decel failure. Remedy:
|
| GFF Ground fault | Cause: The AC drive output is abnormal. When the output terminal is grounded (short circuit current is 50% more than the AC drive rated current), the AC drive power module may be damaged. Remedy:
|
| bb External Base Block | Cause: External Base Block. AC drive output is turned off. Remedy:
|
| FbL PID Feedback Signal Error | Cause: PID Feedback Signal Error. Remedy:
|
| FAnP Fan Power Fault | Cause: Fan Power Fault (150~300HP). Remedy:
|
| FF1 Fan 1 fault | Cause: Fan 1 fault (150~300HP). Remedy:
|
| FF2 Fan 2 fault | Cause: Fan 2 fault (150~300HP). Remedy:
|
| FF3 Fan 3 fault | Cause: Fan 3 fault (150~300HP). Remedy:
|
| FF123 Fan 1, 2, 3 fault | Cause: Fan 1, 2, 3 fault (150~300HP). Remedy:
|
| FF12 Fan 1, 2 fault | Cause: Fan 1, 2 fault (150~300HP). Remedy:
|
| FF13 Fan 1, 3 fault | Cause: Fan 1, 3 fault (150~300HP). Remedy:
|
| FF23 Fan 2, 3 fault | Cause: Fan 2, 3 fault (150~300HP). Remedy:
|
| Fu Gate Drive Low Voltage Protect | Cause: Gate Drive Low Voltage Protect. Remedy:
|
How to Clear & Reset Delta VFD-F Drive Faults
- Keypad Reset: Once the root cause of the error is eliminated, press the red STOP / RESET key on the front digital keypad to clear the active alarm trip.
- Multi-Function Input Terminal Reset (MI): If programmed on terminals MI1 through MI6 (Parameters 04-00 to 04-05 set to
05: External Fault Reset), pulse the corresponding digital input terminal to reset. - Factory Parameter Reset: To clear parameter conflicts and restore default factory settings, access parameter 06-15 (Parameter Reset) and enter value 10.
- Serial Communication Reset: Trigger a reset bit command over RS-485 Modbus RTU communication by sending a fault reset command to control register
2000H. - Complete Power Cycle: Switch off AC mains power, allow at least 10 minutes for high-capacity internal DC bus filter capacitors to fully discharge until the CHARGE LED turns completely off, then power on again.
⚠️ High-Voltage Electrical Safety Warning:
Hazardous residual DC voltages persist inside high-power VFD-F filter capacitors after power is switched off. Always wait a minimum of 10 minutes until the CHARGE LED is completely OFF, and measure with a calibrated multimeter to confirm that DC bus terminal voltage across [+1 / +2] and [-] is strictly below 25VDC before touching power terminals (R/L1, S/L2, T/L3) or motor leads (U/T1, V/T2, W/T3).