Hitachi WJ-C1 drive

Home / Hitachi / Hitachi WJ-C1 drive

Hitachi WJ-C1 Drive Fault Codes & Diagnostic Guide

Complete fault code reference directory, trip alarm causes, and step-by-step diagnostic procedures for the Hitachi WJ-C1 compact multi-purpose inverter series. Search or filter through the complete fault code directory below.

Sensorless Vector (IM & PM Motor Control) Power: 0.1 to 15 kW (0.125 to 20 HP) Integrated Safe Torque Off (STO SIL3 / PLe)
Power Range 0.1 – 15 kW (0.125 – 20 HP)
Supply Voltage 1-Ph 100–240V / 3-Ph 200–480V AC
Control Modes Sensorless Vector (SLV) & V/f
Operator Interface Built-in LED Keypad / Optional WOP LCD

Complete Hitachi WJ-C1 Drive Fault Code Directory

Use the search box in the table below to quickly find your code (e.g., type E01, E07, E030, or Overcurrent).

Fault Code and MeaningCause and Remedy
E01.*

Over current error (Constant speed)

Cause:

  • Is there a steep load change?

  • Is there an output short circuit?

  • Is there a ground fault?




Remedy:

  • Eliminate load fluctuation.

  • Check the output line.

  • Check the output wires and motor.


E02.*

Over current error (During deceleration)

Cause: Rapid deceleration.



Remedy:

  • Increase the deceleration time.


E03.*

Over current error (During acceleration)

Cause:

  • Rapid acceleration.

  • Is motor locked?

  • Is the torque boost high?




Remedy:

  • Increase the acceleration time.

  • Check the motor and wiring.

  • Decrease the boost value.


E04.*

Over current error (Other)

Cause: Is DC braking high?



Remedy:

  • Decrease the DC braking force.


E05.*

Overload error

Cause:

  • Is the acceleration torque insufficient?

  • Is the load too heavy?

  • Is thermal level correct?




Remedy:

  • Increase the acceleration time.

  • Lower the load factor.

  • Set to the proper level.


E06.*

Braking resistor overload error

Cause:

  • Is it decelerating rapidly?

  • Is the operation cycle short?




Remedy:

  • Increase the deceleration time.

  • Increase the operating cycle.


E07.*

Overvoltage error

Cause:

  • Is it decelerating rapidly?

  • Is there a ground fault?

  • Is the motor rotated from the load side?

  • Is the power supply voltage rising?




Remedy:

  • Increase the deceleration time.

  • Check the output wires and motor.

  • Reduce the regeneration amount.

  • Lower the power supply voltage, suppress power fluctuations, or insert an AC reactor into the input.


E08.*

Memory error

Cause:

  • Is there a large noise source nearby?

  • Is the cooling efficiency lowered?




Remedy:

  • Noise suppression.

  • Check for clogging of the cooling fins and clean it, and replace the cooling fans.


E09.*

Undervoltage error

Cause:

  • Power supply voltage is not dropped?

  • Is the power supply capacity insufficient?

  • Is there any aging degradation of the smoothing capacitor?




Remedy:

  • Check the power supply.

  • See "Smoothing Capacitor Life Curve".


E10.*

Current detector error

Cause: Inverter failure.



Remedy:

  • Repair.


E11.*

CPU error

Cause:

  • Is there a large noise source nearby?

  • Inverter failure.




Remedy:

  • Noise suppression.

  • Repair.


E12.*

External trip error

Cause:

  • Is input signal normal?

  • Is there a large noise source nearby?




Remedy:

  • Check the external input device and wiring.

  • Noise suppression.


E13.*

USP error

Cause: Is the power supply turned on with the RUN command input?



Remedy:

  • Check the operation signal.


E14.*

Ground fault

Cause:

  • Is there a ground fault?

  • Is there any abnormality in the inverter alone?

  • Is there any abnormality in the main circuit part?




Remedy:

  • Check the output wires and motor.

  • Disconnect and check the output wires.

  • Check the main circuit. (Refer to "Daily Inspection and Periodic Inspection").


E15.*

Power supply overvoltage error

Cause: Is the power supply voltage too high?



Remedy:

  • Decrease the power supply voltage.

  • Suppress power supply fluctuations.

  • Insert an AC reactor into the input.


E19.*

Temperature detection error

Cause: Inverter failure.



Remedy:

  • Repair.


E21.*

Cooling fin temperature error

Cause:

  • Is the inverter mounted vertically?

  • Is the ambient temperature too high?

  • Is the cooling fan not stopped?

  • Is the cooling fin clogged?




Remedy:

  • Check the installation.

  • Lower the temperature.

  • Set "Cooling fan control method selection [b092]" to "Always (00)" and check fan power supply.

  • Clean the fin.


E22.*

CPU communication error

Cause:

  • Is there a large noise source nearby?

  • Inverter failure.




Remedy:

  • Noise suppression.

  • Repair.


E25.*

Main circuit error

Cause:

  • Is there a large noise source nearby?

  • Inverter failure.




Remedy:

  • Noise suppression.

  • Repair.


E26.*

Analog current input error

Cause:

  • Is [Ai2] wiring short-circuited or incorrect wiring?

  • Control circuit board failure.




Remedy:

  • Check the wiring.

  • Repair.


E30.*

Driver error

Cause:

  • Is there an output short circuit?

  • Is there a ground fault?

  • Is there any damage to the main element?




Remedy:

  • Check the output line.

  • Check the output wires and motor.

  • Checking IGBT (See "Checking the Inverter and Converter Section").


E35.*

Thermistor error (Motor temperature error)

Cause:

  • Is the motor temperature too high?

  • Is there any damage to the thermistor?

  • Is there noise contamination to the thermistor signal?




Remedy:

  • Check the temperature.

  • Check the thermistor.

  • Wiring separation.


E36.*

Brake error

Cause:

  • Is ON/OFF operation of the braking normal?

  • Is the setting of [b124] too short?

  • Is the "Answer back from Brake [BOK]" signal turned on?




Remedy:

  • Check the brake.

  • Increase the [b124].

  • Check wiring.


E37.*

STO shut-off error

Cause:

  • Is [ST1]/[ST2] incorrectly input?

  • Is parameter setting correct?




Remedy:

  • Check the wiring and sequence of [ST1]/[ST2] input signals.

  • Check the [b145] setting.


E38.*

Low-speed range overload error

Cause: Is the load too heavy?



Remedy:

  • Lower the load factor.


E40.*

Remote operator communication error

Cause: Is there a communication error?



Remedy:

  • Check/replace the cable.


E41.*

Modbus communication error

Cause:

  • Is the settings of communication baud rate etc. correct?

  • Are the length and shield of the wirings appropriate? Also, are wires not broken?

  • Is the termination resistor setting correct?




Remedy:

  • Check the settings.

  • Check the communication wiring.

  • Check the termination resistor.


E43.*

EzSQ invalid instruction error

Cause: Invalid instruction detected in EzSQ program.



Remedy:

  • Refer to "Inverter configuration software ProDriveNext instruction manual".


E44.*

EzSQ nesting count error

Cause: Nesting count exceeds allowable executed number.



Remedy:

  • Refer to "Easy-Sequence Function (EzSQ) Programming Guide".


E45.*

EzSQ execution error

Cause: Instruction that cannot be executed is detected.



Remedy:

  • Refer to EzSQ Programming Guide.


E50.* to E59.*

EzSQ user-assigned error 0 to 9

Cause: Corresponding user-assigned tripping programs executed in EzSQ.



Remedy:

  • Check user program logic.


E60.* to E69.*

Option related error

Cause:

  • Is the option board connected properly?

  • Is there a mistake in usage?




Remedy:

  • Check connector fitting.

  • Check the instruction manual for the option.


E80.*

Encoder disconnection error

Cause:

  • Are there any broken or faulty connections in the encoder wiring?

  • Are the parameter settings correct?




Remedy:

  • Check the encoder wiring.

  • Increase [P077] and set [P015] to a higher value.


E81.*

Overspeed error

Cause:

  • Are there any broken or faulty connections in the encoder wiring?

  • Are the parameter settings correct?

  • Is the actual motor speed higher than the error detection level?




Remedy:

  • Check the encoder wiring.

  • Check "Output frequency setting or monitor [F001]" and Encoder constant [P011].

  • Check the load status and adjust [P026].


E83.*

Position control range error

Cause: Is the current position and home position correct?



Remedy:

  • Check [P072] and [P073].

  • Check [P060] to [P067].

  • Check the home position.


E98.*

ST1/ST2 mismatch error

Cause:

  • Is [ST1]/[ST2] incorrectly input?

  • Is parameter setting correct?




Remedy:

  • Check [ST1]/[ST2] input signal wiring and perform function tests.

  • Check the [b145] setting.


E99.*

STO internal failure error

Cause: Is the safety function working properly?



Remedy:

  • Perform function tests.

  • Failure in the internal safety path -> Repair.


How to Clear & Reset Hitachi WJ-C1 Drive Faults

  1. Keypad Reset: Press the red STOP/RESET key on the integrated front LED operator once the trip cause is identified and cleared. For thermal protection trips (E05), allow motor and heat sink cooling time before attempting a reset.
  2. Intelligent Terminal Reset [RS]: Momentarily close and open the multi-function input assigned to Reset function 18 (terminal [RS], programmed via parameters C001 through C007). Turn the [RS] signal OFF to return to standby.
  3. ProDriveNext PC Tool / USB: Connect a PC using the front mini-USB or RS-485 interface with Hitachi ProDriveNext configuration software and execute the “Trip Reset” command from the status monitor window.
  4. Trip History Check: Inspect monitor parameters d081 through d086 via the keypad to verify the last 6 fault records, operating frequency, output current, and DC link voltage recorded at the exact moment of trip.
  5. Power Cycle: Disconnect AC input mains power, wait at least 10 minutes until the front power LED and internal DC bus charge indicator extinguish completely, then re-energize the drive.
⚠️ High-Voltage Electrical Safety Warning: Always verify with a calibrated digital multimeter that intermediate DC bus voltage measures strictly below 50VDC across terminals [+] and [-] (or +1 and -) and wait at least 10 minutes after turning off input AC power before opening the terminal cover or touching motor terminals U/T1, V/T2, and W/T3 on the Hitachi WJ-C1 drive.