LS Electric L7S Servo Drive Fault Codes & Diagnostic Guide
Complete alarm reference directory, trip error causes, and step-by-step troubleshooting procedures for the LS Electric L7S standard AC servo drive series. Search or filter through the complete fault code directory below.
Capacity Range
100W – 15 kW (0.1 – 15 kW)
Supply Voltage
1-Phase / 3-Phase 200–230V / 380–480V
Control Modes
Position, Speed & Torque
Operator Interface
5-Digit 7-Segment Display / DriveCM
Complete LS Electric L7S Servo Drive Fault Code Directory
Use the search box in the table below to quickly find your alarm code (e.g., type AL-11, AL-31, or Overload).
| Fault Code and Meaning | Cause and Remedy |
|---|---|
| AL-10 IPM fault | Cause: Over current (H/W). Remedy:
|
| AL-11 IPM temperature | Cause: IPM overheating. Remedy:
|
| AL-14 Over current | Cause: Over current (S/W). Remedy:
|
| AL-15 Current Offset | Cause: Current offset error. Remedy:
|
| AL-16 Over Current(/CL) | Cause: Over current (H/W). Remedy:
|
| AL-21 Continuous overload | Cause: Continuous overload. Remedy:
|
| AL-22 Room Temperature | Cause: Drive overheating. Remedy:
|
| AL-23 Regen. Overload | Cause: Regenerative overload. Remedy:
|
| AL-24 Motor Cable Open | Cause: Motor disconnection. Remedy:
|
| AL-30 Encoder Comm. | Cause: Serial encoder communication error. Remedy:
|
| AL-31 Encoder Cable Open | Cause: Encoder cable open. Remedy:
|
| AL-32 Encoder Data Error | Cause: Encoder data error. Remedy:
|
| AL-33 Motor Setting Error | Cause: Motor ID setting error. Remedy:
|
| AL-34 Encoder Z PHASE Open | Cause: Encoder Z phase disconnection. Remedy:
|
| AL-35 Low Battery Error | Cause: Low Battery Error. Remedy:
|
| AL-36 Preset Error | Cause: Encoder initialization. Remedy:
|
| AL-40 Under Voltage | Cause: Low Voltage. Remedy:
|
| AL-41 Over Voltage | Cause: Over voltage. Remedy:
|
| AL-42 RS-T Power Fail | Cause: Main power error. Remedy:
|
| AL-43 Control Power Fail | Cause: Control power error. Remedy:
|
| AL-50 Over Speed Limit | Cause: Over speed. Remedy:
|
| AL-51 Position Following | Cause: Excessive positional error. Remedy:
|
| AL-53 Over Pulse CMD | Cause: Pulse command frequency error. Remedy:
|
| AL-54 Speed Deviation | Cause: Excessive speed error. Remedy:
|
| AL-55 Motor Over Run | Cause: Runaway motor. Remedy:
|
| AL-63 Parameter Checksum | Cause: Parameter error. Remedy:
|
| AL-64 Parameter Range | Cause: Parameter range error. Remedy:
|
| AL-71 Invalid Factory Setting | Cause: Factory setting error. Remedy:
|
| AL-72 GPIO Setting | Cause: Output setting error. Remedy:
|
| W-01 RST_PFAIL | Cause: Main power source loss. Remedy:
|
| W-02 LOW_BATT | Cause: Low battery. Remedy:
|
| W-04 OV_TCMD | Cause: Excessive torque command. Remedy:
|
| W-08 OV_VCMD | Cause: Excessive speed command. Remedy:
|
| W-10 OV_LOAD | Cause: Overload warning. Remedy:
|
| W-20 SETUP | Cause: Capacity selection. Remedy:
|
| W-40 UD_VTG | Cause: Low battery warning (DC-link Low Voltage). Remedy:
|
| W-80 EMG | Cause: EMG Contact. Remedy:
|
How to Clear & Reset LS Electric L7S Servo Drive Alarms
- Keypad Reset: In the alarm state display (
AL-XX), press and hold the [SET] key on the front 5-digit panel for at least 1 second to clear the alarm (applicable only to resettable alarm trips). - Digital Input Reset (A-RST): Apply a momentary signal to the digital input terminal assigned to A-RST (Alarm Reset) via the CN1 control signal connector.
- DriveCM PC Software: Connect your PC to the drive via USB or serial loader interface using LS Electric DriveCM configuration software, go to the Alarm Monitor screen, and click Reset Alarm.
- Serial Communication Command: Transmit an alarm reset command frame to the drive over RS-422 serial communications via connector CN3/CN4.
- Power Cycle: Disconnect both the main power (L1, L2, L3) and control power supply (C1, C2), wait until the front display and red CHARGE LED extinguish completely (approx. 3–5 minutes), and re-apply power.
⚠️ High-Voltage Electrical Safety Warning:
Dangerous residual DC voltage remains stored in the internal capacitors after shutting off AC power. Wait until the red CHARGE LED turns completely off and verify with a calibrated digital multimeter that the DC bus voltage measures strictly below 30VDC across terminals [B+] and [B-] before touching motor power wiring U, V, W or encoder connector CN2 on the LS Electric L7S drive.