Complete error code reference directory, alarm trip causes, and step-by-step diagnostic actions for the Panasonic MINAS A6 AC servo driver series (A6SE, A6SG, A6SF, A6N, and A6B). Search or filter through the complete error code table below.

AC Servo Driver Power: 50 W to 5.0 kW Safe Torque Off (STO SIL3) 23-bit Optical/Battery-less Absolute Encoder
Power Range 50 W – 5.0 kW (Ultra-compact)
Supply Voltage 100V / 200V / 400V AC
Control Modes Position, Speed, Torque & Full-Closed
Setup Interface PANATERM (USB) & 5-Key LED Display

Complete Panasonic MINAS A6 Servo Drive Error Code Directory

Use the search box in the table below to look up your code (e.g., type 12.0, 14.0, 16.0, or Overcurrent).

ErrFault Code and Meaning error in Panasonic MINAS A6 series servo driveErrFault Code and Meaning error in Panasonic MINAS A6 series servo drive

Cause and Remedy
Err11.0 error in Panasonic MINAS A6 series servo driveErr11.0 Under voltage protection of control power supply error in Panasonic MINAS A6 series servo drive

Cause: Voltage between P and N of converting unit of control power supply has fallen down and dropped below specified value.

1) Low power supply voltage. Occurrence of momentary power failure.

2) Power capacity shortage due to rush current at main power-on.

3) Servo driver failure (circuit failure).



Remedy: Measure L1C-L2C line voltage of connector and terminal block.

  • Increase the capacity of power supply voltage. Change the power supply.

  • Increase the power capacity.

  • Replace with new servo driver.

Err12.0 error in Panasonic MINAS A6 series servo driveErr12.0 Over-voltage protection error in Panasonic MINAS A6 series servo drive

Cause: Voltage between P and N of the converter portion of the control power supply has exceeded the specified value.

1) Power supply voltage exceeded permissible input. Surge from phase-advancing capacitor or UPS.

2) Disconnection of regeneration discharge resistor.

3) External regeneration resistor not appropriate (could not absorb energy).

4) External regeneration discharge resistor not appropriate.

5) Failure of servo driver.



Remedy: Measure the voltage between lines of connector (L1, L2 and L3).

  • Enter correct voltage. Remove a phase-advancing capacitor.

  • Measure resistance of external resistor between P-B. Replace if value is ∞.

  • Change the specified regeneration resistance value to wattage.

  • Change to one with specified resistance and wattage.

  • Check that Pr0.16 is set correctly.

Err13.0 error in Panasonic MINAS A6 series servo driveErr13.0 Main power supply under-voltage protection (PN) error in Panasonic MINAS A6 series servo drive

Cause: Instantaneous power failure occurred between L1 and L3 longer than preset time (Pr5.09) or voltage between P and N fell below specified value.

1) Power supply voltage is low / Instantaneous power failure.

2) Lack of power capacity (voltage drop due to inrush current).

3) Phase lack (3-phase driver operated with single phase).

4) Failure of servo driver.



Remedy: Measure the voltage between lines of connector (L1, L2 and L3).

  • Increase power capacity. Change power supply. Remove causes of shutdown (magnetic contactor), then re-enter power.

  • Set up longer time to Pr5.09 (Main power off detecting time).

  • Increase power capacity (refer to driver preparation list).

  • Connect each phase (L1, L2, L3) correctly. (For single phase, use L1 and L3).

  • Replace the driver with a new one.

Err13.1 error in Panasonic MINAS A6 series servo driveErr13.1 Main power supply under-voltage protection (AC) error in Panasonic MINAS A6 series servo drive

Cause: AC Power supply issues similar to 13.0 (Low voltage, phase failure, etc).



Remedy:

  • Check input voltage levels.

  • Verify wiring configuration (System Configuration).

  • See remedies for Error 13.0.

Err14.0 error in Panasonic MINAS A6 series servo driveErr14.0 Over-current protection error in Panasonic MINAS A6 series servo drive

Cause: Current through the converter portion has exceeded the specified value.

1) Failure of servo driver (IGBT or other components).

2) Short of the motor wire (U, V and W).

3) Earth fault of the motor wire.

4) Burnout of the motor.

5) Poor contact of the motor wire.

6) Welding of contact of dynamic braking relay (frequent ON/OFF).

7) Pulse input timing error.

8) Blowout of thermal fuse.

9) Power Module overheat.



Remedy:

  • Turn to Servo-ON while disconnecting motor. If error occurs immediately, replace driver.

  • Check motor wires (U, V, W) are not shorted. Check connectors. Correct wiring.

  • Measure insulation resistance between motor wires and earth. Replace motor if poor.

  • Check balance of resistance between motor lines. Replace motor if unbalanced.

  • Fix loose connectors.

  • Replace servo driver. Avoid using Servo-ON/OFF to start/stop operation.

  • Enter pulses 100 ms or longer after Servo-ON.

  • Increase capacity of servo driver and motor. Set longer acceleration/deceleration time. Reduce load.

Err14.1 error in Panasonic MINAS A6 series servo driveErr14.1 IPM error protection error in Panasonic MINAS A6 series servo drive

Cause: Intelligent Power Module error detected (Often associated with Over-current causes).



Remedy:

  • See remedies for Error 14.0.

  • Check for short circuits or earth faults in motor wiring.

  • Replace driver if internal module is damaged.

Err15.0 error in Panasonic MINAS A6 series servo driveErr15.0 Over-heat protection error in Panasonic MINAS A6 series servo drive

Cause: Temperature of heat sink or power device has risen over specified temperature.

1) Ambient temperature high.

2) Over-load.



Remedy:

  • Improve ambient temperature and cooling condition.

  • Increase capacity of driver and motor.

  • Set up longer acceleration/deceleration time.

  • Lower the load.

Err15.1 error in Panasonic MINAS A6 series servo driveErr15.1 Encoders abnormal Over-heat protection error in Panasonic MINAS A6 series servo drive

Cause: The temperature of encoder has exceeded an encoder overheat abnormal level.

1) Ambient temperature of servomotor is high.

2) Overload.



Remedy:

  • Improve the ambient temperature of servomotor and cooling condition.

  • Increase capacity of servo driver and motor.

  • Set up longer acceleration/deceleration time.

  • Reduce the load.

Err16.0 error in Panasonic MINAS A6 series servo driveErr16.0 Over-load protection error in Panasonic MINAS A6 series servo drive

Cause: Torque command value exceeded over-load level (Pr5.12) for a specific time.

1) Load heavy / continuous high torque.

2) Oscillation/hunching due to poor adjustment.

3) Miswiring or disconnection.

4) Machine collision or distortion.

5) Electromagnetic brake kept engaged.

6) Miswiring multiple axes.



Remedy: Check torque (current) monitor and load factor.

  • Increase capacity of driver/motor. Set longer accel/decel time. Lower load.

  • Make a re-adjustment (Gain).

  • Check wiring diagram and replace cables.

  • Remove cause of distortion / Lower load.

  • Measure voltage between brake terminals. Release brake.

  • Make correct wiring by matching motor and encoder wires.

Err16.1 error in Panasonic MINAS A6 series servo driveErr16.1 Torque saturation anomaly protection error in Panasonic MINAS A6 series servo drive

Cause: Torque saturation has continued for the time set in Pr6.57.



Remedy:

  • Check operation of the driver.

  • Refer to Measures described for Err16.0.

Err18.0 error in Panasonic MINAS A6 series servo driveErr18.0 Over-regeneration load protection error in Panasonic MINAS A6 series servo drive

Cause: Regenerative energy exceeded capacity of regenerative resistor.

1) Large load inertia / High converter voltage.

2) High motor rotational speed.

3) Active limit of external resistor limited to 10% duty.



Remedy: Check load factor of regenerative resistor.

  • Check running pattern (velocity monitor). Increase driver/motor capacity. Loosen deceleration time.

  • Use an external regenerative resistor.

  • Set up Pr0.16 to 2.

  • Caution: Install thermal fuse when using external resistor to prevent burnout.

Err18.1 error in Panasonic MINAS A6 series servo driveErr18.1 Regenerative transistor error protection error in Panasonic MINAS A6 series servo drive

Cause: Regenerative driver transistor on the servo driver is defective.



Remedy:

  • Replace the driver.

Err21.0 error in Panasonic MINAS A6 series servo driveErr21.0 Encoder communication disconnection error in Panasonic MINAS A6 series servo drive

Cause: Communication between encoder and driver interrupted.



Remedy:

  • Make wiring connection of encoder as per wiring diagram.

  • Correct miswiring of connector pins.

Err21.1 error in Panasonic MINAS A6 series servo driveErr21.1 Encoder communication error protection error in Panasonic MINAS A6 series servo drive

Cause: Data error due to noise. Encoder cables connected but data has errors.



Remedy:

  • Secure power supply for encoder (DC4.90 V to 5.25 V). Pay attention to long cables.

  • Separate encoder cable and motor cable (do not bind together).

  • Connect shield to FG.

Err23.0 eerror in Panasonic MINAS A6 series servo driveErr23.0 Encoder communication data error protection error in Panasonic MINAS A6 series servo drive

Cause: Communication valid but data content incorrect. Mainly due to noise.



Remedy:

  • Check noise sources.

  • Separate encoder cables from high voltage lines.

  • Connect shield to FG.

Err24.0 error in Panasonic MINAS A6 series servo driveErr24.0 Position deviation excess protection error in Panasonic MINAS A6 series servo drive

Cause: Deviation pulses exceeded Pr0.14 setup.

1) Motor movement has not followed command.

2) Setup value of Pr0.14 is small.



Remedy:

  • Check motor follows position command pulses.

  • Make gain adjustment. Set max value to Pr0.13 and Pr5.22.

  • Check encoder wiring.

  • Set longer accel/decel time. Lower load/speed.

  • Set a larger value to Pr0.14.

Err24.1 error in Panasonic MINAS A6 series servo driveErr24.1 Speed deviation excess protection error in Panasonic MINAS A6 series servo drive

Cause: Difference between internal positional command speed and actual speed exceeds Pr6.02.



Remedy:

  • Increase setup value of Pr6.02.

  • Lengthen acceleration/deceleration time.

  • Improve follow-up characteristic by adjusting gain.

  • Disable excess speed deviation detection (Pr6.02 = 0).

Err25.0 error in Panasonic MINAS A6 series servo driveErr25.0 Hybrid deviation excess error protection error in Panasonic MINAS A6 series servo drive

Cause: Position of load (external scale) vs motor (encoder) slips larger than Pr3.28.

Also caused if division/multiplication changed during full closed control.



Remedy:

  • Check connection between motor and load.

  • Check connection between external scale and driver.

  • Check scale signs/direction (Pr3.24, 3.25, 3.26).

  • Do not change command division/multiplication during full closed control.

Err26.0 error in Panasonic MINAS A6 series servo driveErr26.0 Over-speed protection error in Panasonic MINAS A6 series servo drive

Cause: Motor rotational speed exceeded setup value of Pr5.13.



Remedy:

  • Do not give excessive speed command.

  • Check command pulse input frequency and division ratio.

  • Make gain adjustment (overshoot).

  • Check encoder wiring.

Err26.1 error in Panasonic MINAS A6 series servo driveErr26.1 2nd Over-speed protection error in Panasonic MINAS A6 series servo drive

Cause: Motor rotational speed exceeded setup value of Pr6.15.



Remedy:

  • Check speed command and gain settings (see measures for 26.0).

Err27.0 error in Panasonic MINAS A6 series servo driveErr27.0 Command pulse input frequency error error in Panasonic MINAS A6 series servo drive

Cause: Frequency of command pulse input is more than 1.2 times the setting in Pr5.32.



Remedy:

  • Check the command pulse input for frequency.

Err27.1 error in Panasonic MINAS A6 series servo driveErr27.1 Absolute clear abnormal protection error in Panasonic MINAS A6 series servo drive

Cause: Absolute encode multi-rotation clear executed when block operation was enabled (Pr 6.28 is not 0).



Remedy:

  • Confirm whether absolute encode multi-rotation clear was intended.

  • Note: This is a safety measure and is not an abnormality.

Err27.2 error in Panasonic MINAS A6 series servo driveErr27.2 Command pulse multiplier error error in Panasonic MINAS A6 series servo drive

Cause: Division/Multiplication ratio settings (electronic gear) not appropriate.

Calculated pulses exceed 3000 Mpps.

Noise on command pulse.

Backlash correction error.



Remedy:

  • Set command division/multiplication ratio to a value as small as possible (1/1000 to 1000).

  • Check setup of electronic gear.

  • Use line driver I/F if possible.

  • Set Pr5.32 to value < 1000 and enable digital filter.

  • Check Pr 7.05 "Backlash Correction Amount".

Err28.0 error in Panasonic MINAS A6 series servo driveErr28.0 Limit of pulse replay protection error in Panasonic MINAS A6 series servo drive

Cause: The output frequency of pulse regeneration has exceeded the limit.



Remedy:

  • Check setup values of Pr0.11 and 5.03.

  • To disable detection, set Pr5.33 to 0.

Err29.0 error in Panasonic MINAS A6 series servo driveErr29.0 Deviation counter overflow protection error in Panasonic MINAS A6 series servo drive

Cause: Position deviation value of encoder pulse standard exceeded 2^30-1.



Remedy:

  • Check that motor follows position command.

  • Check output torque not saturated.

  • Make gain adjustment.

  • Maximize Pr0.13 (1st torque limit) and Pr5.22 (2nd torque limit).

  • Check encoder connection.

Err29.1 error in Panasonic MINAS A6 series servo driveErr29.1 Counter overflow error protection 1 error in Panasonic MINAS A6 series servo drive

Cause: Value of absolute encoder position/electronic gear ratio exceeded limit during initialization.



Remedy:

  • Confirm operating range of absolute encoder (absolute external scale).

  • Review the electronic gear ratio.

Err29.2 error in Panasonic MINAS A6 series servo driveErr29.2 Counter overflow error protection 2 error in Panasonic MINAS A6 series servo drive

Cause: Value of positioning deviation has exceeded limit in pulse units or command units.



Remedy:

  • Confirm motor rotates in accordance with positioning command.

  • Confirm output torque not saturated. Adjust gain.

  • Set Torque limits (Pr0.13, Pr5.22) to maximum.

  • Connect encoder wiring correctly.

Err31.0 error in Panasonic MINAS A6 series servo driveErr31.0 Safety function error protection error in Panasonic MINAS A6 series servo drive

Cause: Safety function has detected an error.



Remedy:

  • In case of repeated occurrence, replace the servo driver.

  • Return to dealer for investigation/repair.

Err33.0 error in Panasonic MINAS A6 series servo driveErr33.0 - Err33.7 I/F overlap allocation / Input function errors error in Panasonic MINAS A6 series servo drive

Cause:

33.0: Input signals (SI1-SI5) assigned with two functions.

33.1: Input signals (SI6-SI10) assigned with two functions.

33.2: Input signals (SI1-SI5) assigned with undefined number.

33.3: Input signals (SI6-SI10) assigned with undefined number.

33.4: Output signals (SO1-SO3) assigned with undefined number.

33.5: Output signals (SO4-SO6) assigned with undefined number.

33.6: Counter clear assigned to signal other than SI7.

33.7: Command pulse inhibit assigned to signal other than SI10.



Remedy:

  • Allocate correct function to each connector pin.

  • Check signal assignments.

Err34.0 error in Panasonic MINAS A6 series servo driveErr34.0 Motor working range setup error protection error in Panasonic MINAS A6 series servo drive

Cause: Motor exceeded working range set to Pr5.14.



Remedy:

  • Check gain (balance between position loop and speed loop) and inertia ratio.

  • Increase setup value of Pr5.14.

  • Set Pr5.14 to 0 to disable protective function.

Err36.0 / Err36.1 error in Panasonic MINAS A6 series servo driveErr36.0 / Err36.1 EEPROM parameter error protection error in Panasonic MINAS A6 series servo drive

Cause: Data in parameter storage area damaged when reading from EEPROM at power-on.



Remedy:

  • Set up all parameters again.

  • If error persists, replace the driver (may be a failure).

Err37.0 / Err37.1 / Err37.2 error in Panasonic MINAS A6 series servo driveErr37.0 / Err37.1 / Err37.2 EEPROM check code error protection error in Panasonic MINAS A6 series servo drive

Cause: Data for writing confirmation to EEPROM has been damaged.



Remedy:

  • Replace the driver (it may be a failure).

Err38.0 error in Panasonic MINAS A6 series servo driveErr38.0 Drive prohibition input protection error in Panasonic MINAS A6 series servo drive

Cause:

Both positive and negative direction drive prohibition inputs (POT and NOT) have been turned ON at Pr5.04 “Over-travel inhibition input setting” =0.

Either positive direction drive prohibition input or negative direction drive prohibition input has been turned ON at Pr5.04=2.



Remedy:

Check that there is no error in the switches, wires and power supply connected to the positive direction/negative direction drive prohibition input. Check particularly that start-up of the power supply for the control signal (DC12 to 24 V) is not slow.
Err39.0 error in Panasonic MINAS A6 series servo driveErr39.0 Analog input 1 (AI1) excess protection error in Panasonic MINAS A6 series servo drive

Cause:

The voltage more than the value set in Pr4.24 “Analog input 1 (AI1) excess setup” has been applied to analog input 1.



Remedy:


  • Correctly set Pr4.24 “Analog input 1 (AI1) excess setup.”

  • Check the connection of I/F connector.

  • Set Pr4.24 to 0 and disable the protective function.

Err39.1 error in Panasonic MINAS A6 series servo driveErr39.1 Analog input 2 (AI2) excess protection error in Panasonic MINAS A6 series servo drive

Cause:

The voltage more than the value set in Pr4.27 “Analog input 2 (AI2) excess setup” has been applied to analog input 2.



Remedy:


  • Correctly set Pr4.27 “Analog input 2 (AI2) excess setup.”

  • Check the connection of I/F connector.

  • Set Pr4.27 to 0 and disable the protective function.

Err39.2 error in Panasonic MINAS A6 series servo driveErr39.2 Analog input 3 (AI3) excess protection error in Panasonic MINAS A6 series servo drive

Cause:

The voltage more than the value set in Pr4.30 “Analog input 3 (AI3) excess setup” has been applied to analog input 3.



Remedy:


  • Correctly set Pr4.30 “Analog input 3 (AI3) excess setup.”

  • Clear the absolute encoder first to execute the alarm clear.

  • Check the connection of I/F connector.

  • Set Pr4.30 to 0 and disable the protective function.

Err40.0 error in Panasonic MINAS A6 series servo driveErr40.0 Absolute system down error protection error in Panasonic MINAS A6 series servo drive

Cause:

The power supplies and battery powers to absolute encoder were shut down, and the built-in capacitor voltage dropped below specified value.
Caution: Once this error occurs, the alarm cannot be cleared until the absolute encoder is reset.




Remedy:

After connecting the power supply for the battery, clear the absolute encoder.

  • If you use the incremental system Pr 0.15 "sets the absolute encoder" is set to 1.

Err41.0 error in Panasonic MINAS A6 series servo driveErr41.0 Absolute counter over error protection error in Panasonic MINAS A6 series servo drive

Cause:

Multi-turn counter of the absolute encoder has exceeded the specified value.



Remedy:


  • Set Pr0.15 to 2 to ignore the multi-turn counter over.

  • Limit the travel from the machine origin within 32767 revolutions.

Err42.0 error in Panasonic MINAS A6 series servo driveErr42.0 Absolute over-speed error protection error in Panasonic MINAS A6 series servo drive

Cause:

When using absolute encoder:

1) During a power failure, when only battery power is supplied, the motor rotational speed has exceeded the specified value.

2) During normal operation, for some reason, the power of encoder has been shut down, and the rotational speed has exceeded the specified value.
Caution: Once this error occurs, the alarm cannot be cleared until the absolute encoder is reset.




Remedy:

1) Check the external driving force for motor and the rotational speed at the time, and operate to make the speed below specified value.

2) The mode was switched to a power failure mode during normal operation. Check the power supply voltage of encoder side (5V±5 %). Check the connection of connector X6.
Err44.0 error in Panasonic MINAS A6 series servo driveErr44.0 Absolute single turn counter error / Incremental single turn counter error error in Panasonic MINAS A6 series servo drive

Cause:

Absolute encoder has detected a single turn counter error.

Serial incremental encoder has detected an error in the incremental counter value of single turn counter (between z-phase signals).



Remedy:

Replace the motor.
Err45.0 error in Panasonic MINAS A6 series servo driveErr45.0 Absolute multi-turn counter error / Incremental counter error error in Panasonic MINAS A6 series servo drive

Cause:

Absolute encoder has detected a multi-turn counter error.

Serial incremental encoder has detected an error in the incremental counter values between CS signals.



Remedy:

Replace the motor.

If you use the incremental system, check if Pr 0.15 "sets the absolute encoder" is set to 1.
Err47.0 error in Panasonic MINAS A6 series servo driveErr47.0 Absolute status error protection error in Panasonic MINAS A6 series servo drive

Cause:

When power is turned on, absolute encoder has been rotated at the specified value or above.



Remedy:

Arrange so as the motor does not run at power-on.
Err50.0 error in Panasonic MINAS A6 series servo driveErr50.0 External scale wiring error protection error in Panasonic MINAS A6 series servo drive

Cause:

Communication between the external scale and the driver has been interrupted in certain times, and disconnection detecting function has been triggered.



Remedy:


  • Make a wiring connection of the external scale as per the wiring diagram.

  • Correct the miswiring of the connector pins.

Err50.1 error in Panasonic MINAS A6 series servo driveErr50.1 External scale communication data error protection error in Panasonic MINAS A6 series servo drive

Cause:

Communication error has occurred in data from the external scale. Mainly data error due to noise. External scale cables are connected, but communication date has some error.



Remedy:


  • Secure the power supply for the external scale of DC5±5 % (4.75 V to 5.25 V). Pay attention especially when the external scale cables are long.

  • Separate the external scale cable and the motor cable if they are bound together.

  • Connect the shield to FG (refer to wiring diagram).

Err50.2 error in Panasonic MINAS A6 series servo driveErr50.2 External displacement sensor communication data error protection error in Panasonic MINAS A6 series servo drive

Cause:

External displacement sensor communication has no error, but error occurred in data. External displacement sensor communication data error mainly due to noise.



Remedy:

Connect the shield to FG (refer to wiring diagram).
Err51.0 error in Panasonic MINAS A6 series servo driveErr51.0 External scale status 0 error protection error in Panasonic MINAS A6 series servo drive

Cause:

Bit 0 of the external scale error code (ALMC) has been turned to 1.

Check the specifications of the external scale.



Remedy:

Remove the causes of the error, then clear the external scale error from the front panel. And then, shut off the power to reset.
Err51.1 error in Panasonic MINAS A6 series servo driveErr51.1 External scale status 1 error protection error in Panasonic MINAS A6 series servo drive

Cause:

Bit 1 of the external scale error code (ALMC) has been turned to 1.

Check the specifications of the external scale.



Remedy:

(Same as above) Remove causes, clear error, shut off power to reset.
Err51.2 error in Panasonic MINAS A6 series servo driveErr51.2 External scale status 2 error protection error in Panasonic MINAS A6 series servo drive

Cause:

Bit 2 of the external scale error code (ALMC) has been turned to 1.

Check the specifications of the external scale.



Remedy:

Remove the causes of the error, then clear the external scale error from the front panel. And then, shut off the power to reset.
Err51.3 error in Panasonic MINAS A6 series servo driveErr51.3 External scale status 3 error protection error in Panasonic MINAS A6 series servo drive

Cause:

Bit 3 of the external scale error code (ALMC) has been turned to 1.

Check the specifications of the external scale.



Remedy:

(Refer to general external scale error handling).
Err51.4 error in Panasonic MINAS A6 series servo driveErr51.4 External scale status 4 error protection error in Panasonic MINAS A6 series servo drive

Cause:

Bit 4 of the external scale error code (ALMC) has been turned to 1.

Check the specifications of the external scale.



Remedy:

(Refer to general external scale error handling).
Err51.5 error in Panasonic MINAS A6 series servo driveErr51.5 External scale status 5 error protection error in Panasonic MINAS A6 series servo drive

Cause:

Bit 5 of the external scale error code (ALMC) has been turned to 1.

Check the specifications of the external scale.



Remedy:

Remove the causes of the error, then clear the external scale error from the front panel. And then, shut off the power to reset.
Err55.0 .error in Panasonic MINAS A6 series servo driveErr55.0 A-phase wiring error protection error in Panasonic MINAS A6 series servo drive

Cause:

A-phase wiring in the external scale is defective, e.g. discontinued.



Remedy:

When using serial communication type external displacement sensor, please change the setting value of Pr3.23 external displacement sensor type selection to:

1 : serial communication type(incremental specification)

or 2 : serial communication type(absolute specification).
Err55.1 error in Panasonic MINAS A6 series servo driveErr55.1 B-phase wiring error protection error in Panasonic MINAS A6 series servo drive

Cause:

B-phase wiring in the external scale is defective, e.g. discontinued.



Remedy:

(Same as above) Change setting value of Pr3.23.
Err55.2 error in Panasonic MINAS A6 series servo driveErr55.2 Z-phase wiring error protection error in Panasonic MINAS A6 series servo drive

Cause:

Z-phase wiring in the external scale is defective, e.g. discontinued.



Remedy:

(Same as above) Change setting value of Pr3.23.
Err70.0 error in Panasonic MINAS A6 series servo driveErr70.0 U-phase current detector error protection error in Panasonic MINAS A6 series servo drive

Cause:

U-phase current offset error is detected.



Remedy:


  • Turn off the power once, then re-enter.

  • If error repeats, this might be a failure. Stop using the products, and replace the motor and the driver. Return the products to the dealer or manufacturer.

Err70.1 error in Panasonic MINAS A6 series servo driveErr70.1 W-phase current detector error protection error in Panasonic MINAS A6 series servo drive

Cause:

W-phase current offset error is detected.



Remedy:

(Same as U-phase error) Turn off power, re-enter. If repeats, replace unit.
Err71.0 error in Panasonic MINAS A6 series servo driveErr71.0 CCWTL anomaly protection error in Panasonic MINAS A6 series servo drive

Cause:

11 V or more at analog input 2 or -11 V or less was applied.



Remedy:

Check the connection status of the I/F connector. Turn the power off and then on again.
Err71.1 error in Panasonic MINAS A6 series servo driveErr71.1 CWTL anomaly protection error in Panasonic MINAS A6 series servo drive

Cause:

11 V or more at analog input 3 or -11 V or less applied.



Remedy:

Check the connection status of the I/F connector. Turn the power off and then on again.
Err72.0 error in Panasonic MINAS A6 series servo driveErr72.0 Thermal error protection error in Panasonic MINAS A6 series servo drive

Cause:

Thermal protector error is detected.



Remedy:

Check motor temperature and wiring.
Err80.0 error in Panasonic MINAS A6 series servo driveErr80.0 Modbus communication timeout protection error in Panasonic MINAS A6 series servo drive

Cause:

While ensuring Modbus execution right, Modbus communication against own axis has not been received for more than the set time.



Remedy:


  • Set Pr5.40 ”Modbus communication timeout period” to 0 to be disabled or to appropriate time.

  • Check the connection of Modbus communication.

Err87.0 error in Panasonic MINAS A6 series servo driveErr87.0 Forced alarm input protection error in Panasonic MINAS A6 series servo drive

Cause:

Forced alarm input (E-STOP) is applied.



Remedy:

Check the wiring of forced alarm input (E-STOP).
Err92.0 error in Panasonic MINAS A6 series servo driveErr92.0 Encoder data recovery abnormal protection error in Panasonic MINAS A6 series servo drive

Cause:

Initialization process of internal position information has not conducted normally under absolute and semi-closed control mode.



Remedy:


  • Secure encoder power supply voltage at DC5V±5% (4.75 to 5.25V). Care must be taken when the encoder lines are lengthy.

  • If motor wires and encoder wires are bundled together, separate them.

  • Connect shield to FG.

Err92.1 error in Panasonic MINAS A6 series servo driveErr92.1 External scale data recovery error protection error in Panasonic MINAS A6 series servo drive

Cause:

Internal position information initialization error under full-closed control and absolute mode with block operation enabled.



Remedy:


  • Secure external scale power supply voltage of 5 VDC±5% (4.75 to 5.25 V).

  • In case the motor line and the external scale connecting cable are bundled together, separate them.

  • Connect shield to FG. Refer to external scale connecting diagram.

Err92.3 error in Panasonic MINAS A6 series servo driveErr92.3 Multi-rotation upper limit value inconsistency error protection error in Panasonic MINAS A6 series servo drive

Cause:

At continuous rotating absolute encoder function, there was a disagreement between the upper-limit value of encoder multi-turn data and the upper-limit value of driver parameter multi-turn data.



Remedy:


  • Please confirm the set values of parameters.

  • Reclose the control power supply when this occurs immediately after closing the control power supply. (This is not an abnormality.)

Err93.0 error in Panasonic MINAS A6 series servo driveErr93.0 Parameter setup error 1 error in Panasonic MINAS A6 series servo drive

Cause:

1) Electronic gear ratio exceeds the allowable range.

2) When a block operation was enabled(Pr 6.28 is non 0), Modbus connection was disabled (Pr 5.37 is 0).

3) When the backlash correction function is enabled (Pr 7.04 = bit 1 - 0 is other than 0) and no block operation is performed (Pr 6.28 = 0), the value of Pr 7.18 "backlash correction amount holding range" converted to pulse units by the electronic gear ratio exceeds 2147483647.



Remedy:

Check the setting value of the parameter.

1) When a block operation was enabled (Pr 6.28 is non 0), Electronic gear ratio must be in the range 1/1000 to 8000.

2) When a block operation was enabled (Pr 6.28 is non 0), Modbus connection was disabled (Pr 5.37 is 0).

3) Check the setting of Pr 7.18 "Retention range of backlash compensation" and electronic gear ratio.
Err93.1 error in Panasonic MINAS A6 series servo driveErr93.1 Block data setting error protection error in Panasonic MINAS A6 series servo drive

Cause:

1) The blocking action was activated by setting the velocity, acceleration and deceleration to 0 or by setting the acceleration and deceleration to values exceeding 4294967295 [command unit/s²].

2) The conditional branch command does not correspond to the comparison target.

3) The command for the specified block data is not defined.

4) In addition, there is an error in the block data setting.



Remedy:

1) Check speed, acceleration and deceleration values.

2) Check if there are any problems with the conditional branch command or comparison target.

3) Check if there are any problems with the block data. Check if there are any problems with the block number specification.

4) Check if there are any problems with the block data setting.
Err93.2 error in Panasonic MINAS A6 series servo driveErr93.2 Parameter setting error protection 2 error in Panasonic MINAS A6 series servo drive

Cause:

External scale ratio has exceeded the allowable range (1/160000 to 160000 times).



Remedy:


  • Please confirm the set values of parameters.

  • Use external scale ratio in the range of 1/40 to 1280 times.

Err93.3 error in Panasonic MINAS A6 series servo driveErr93.3 External scale connection error protection error in Panasonic MINAS A6 series servo drive

Cause:

Set value for Pr3.23 “External scale type selection” and the connected serial communication type external scale type to not match.



Remedy:

Set Pr3.23 to match the type of the connected external scale.
Err94.0 error in Panasonic MINAS A6 series servo driveErr94.0 Block operation error protection error in Panasonic MINAS A6 series servo drive

Cause:

1) During the execution of movement system command (During the execution of position command creation process), a new movement system command has been executed.

2) During block operation, a new block number was designated to start.

3) Although it was servo-off, a block operation was started.



Remedy:

1) Check whether the block operation sequence does not have any problems.

2) Check whether the host sequence does not have any problems.

3) Check whether the host sequence does not have any problems.
Err94.2 error in Panasonic MINAS A6 series servo driveErr94.2 Return to origin error protection error in Panasonic MINAS A6 series servo drive

Cause:

1) Return to origin command of block operation was executed in the absolute mode.

2) In the return to origin operation of the block operation, the prohibited driving input in the return to origin direction was turned ON, and the prohibited driving input in the opposite direction to the return to origin direction was turned ON during the reverse operation.

3) In the return to origin operation of the block operation, both POT and NOT of the driving prohibited input were turned on.

4) Relative or absolute positioning was performed in the uncompleted return to origin state.



Remedy:

1) Check the block data setting or the absolute mode setting for any problems.

2) Check if there are any problems in the arrangement relation between the driving prohibited input and the origin (Sensor input, Z-phase).

3) Check if there are any problems in the arrangement relation between the driving prohibited input.

4) Check if there are any problems in the block data setting.
Err95.0 error in Panasonic MINAS A6 series servo driveErr95.0 to 4 Motor automatic recognition error protection error in Panasonic MINAS A6 series servo drive

Cause:

The motor and the driver has not been matched.



Remedy:

Replace the motor which matches to the driver.
Err96.2 error in Panasonic MINAS A6 series servo driveErr96.2 Control unit error protection 1 error in Panasonic MINAS A6 series servo drive

Cause:

Control circuit has malfunctioned due to excess noise or other causes.

Some error has occurred inside of the driver, which triggered self-diagnosis function of the driver.



Remedy:

Turn off power once, and turn on again. Even so, if an error indication appears, failure is possible. Discontinue to use and replace the motor and servo driver. Return to a dealer for investigation(repair).
Err97.0 error in Panasonic MINAS A6 series servo driveErr97.0 Control mode setting error protection error in Panasonic MINAS A6 series servo drive

Cause:

1) Block operation was enabled except for position control (Pr 0.01 = 0) or full close control (Pr 0.01 = 6).

2) When Pr 6.28 "Special function setting" = 4 (block operation enabled by starting input signal) was set, Pr 0.15 "Absolute encoder setting" = 1 (increment mode) was set.



Remedy:

1) Check the settings of Pr 0.01 "Control mode setting" and Pr 6.28 "Special function selection."

2) Check the settings of Pr 6.28 "Special function setting" and Pr 0.15 "Absolute encoder setting."

How to Clear & Reset Panasonic MINAS A6 Drive Errors

  1. Front Panel Button Reset: On the driver front panel, navigate to the error display mode using the [MODE] button, then press and hold the [SET] button for approximately 3 seconds until the display clears.
  2. Digital Input Signal (A-CLR): Turn ON the Alarm Clear input terminal (A-CLR) by applying a continuous signal for at least 120 ms. Ensure the servo-off condition is established before asserting the clear signal.
  3. PANATERM Setup Software: Connect a PC using a standard mini-USB cable to connector X1, open the PANATERM support tool, navigate to the Alarm screen, and click “Alarm Clear”.
  4. Communication Command: If operating via EtherCAT (A6B) or RTEX (A6N), transmit the fault reset control command word via the master PLC or network motion controller.
  5. Control Power Cycle: Critical non-resettable alarms (such as Err 12.0 Overcurrent, Err 13.0 Main Power Undervoltage, or Err 14.0 Overvoltage) cannot be cleared via software or digital inputs. Turn OFF control power (L1C, L2C) and main power (L1, L2, L3), wait for the front-panel CHARGE LED to fully turn off, resolve the mechanical or wiring cause, and reapply power.
⚠️ High-Voltage Electrical Safety Warning: Before disconnecting motor leads, checking regenerative resistor connections, or touching power terminals (L1, L2, L3, P, B, N, U, V, W), disconnect all incoming electrical power and confirm that the red CHARGE LED has completely turned off. Always measure with a calibrated voltmeter to verify DC intermediate bus voltage is safely below 50VDC.