The A79B event indicates a direct short circuit condition detected within the brake chopper transistor or external dynamic braking circuit on the ABB ACH180. The drive inhibits chopper firing and locks out modulation to prevent a catastrophic short across the intermediate DC bus.
The internal dynamic brake chopper switch is connected directly across the high-voltage intermediate DC bus rail (UDC+ / R+) and the negative return path through terminal R-. If an external braking resistor fails with a shorted turn-to-turn segment, or if the chopper IGBT punctures through electrical overstress, turning on the switch creates a direct dead short across the DC bus capacitor bank. The ACH180 hardware desaturation protection detects the excessive current surge instantaneously, suppresses gate pulses, and asserts code A79B to prevent catastrophic capacitor venting and rectifier diode failure.
What Causes A79B in ABB ACH180?
- Internal electrical puncture or collector-to-emitter short circuit across the brake chopper IGBT.
- Direct electrical short circuit or insulation breakdown between conductors connected to terminals
R+andR-. - External dynamic braking resistor element collapsed or shorted internally to its grounded metallic cage.
- Connecting a dynamic brake resistor with an ohmic value below the specified absolute minimum resistance
Rmin. - Defective external brake chopper module in systems utilizing external dynamic braking chopper units.
Step-by-Step Troubleshooting and Solutions
- Isolate Dynamic Resistor Connections: Cut mains AC input on terminals
L1, L2, L3, wait5 minutesfor the DC link to discharge below50V DC, and disconnect wiring from terminalsR+andR-. - Measure Resistor Resistance: Using a calibrated digital multimeter, measure the resistance of the isolated resistor bank; verify that it matches the nameplate and exceeds the drive minimum allowable resistance
Rmin. - Perform Insulation Megger Test: Run a
500V DCinsulation resistance test between resistor terminals and chassis ground; confirm that the insulation resistance exceeds100 MΩ. - Test Internal Chopper IGBT: With leads disconnected, place your multimeter in diode check mode across terminals
UDC+ / R+andR-; verify that the internal chopper switch is not shorted in both directions. - Service or Replace Hardware: If the external resistor and cabling are healthy but the short circuit indication returns, the internal chopper IGBT has failed, requiring unit replacement.
Preventative Maintenance to Avoid A79B Alarms
Verify that dynamic braking resistors strictly respect drive minimum resistance limits (Rmin), install thermal overload relays in series with resistor banks, and use high-temperature cabling within dynamic braking circuits.
Frequently Asked Questions (FAQs)
What is the meaning of A79B alarm in ABB ACH180 drive?
The A79B alarm indicates that the drive has detected a dead short circuit across the brake chopper power switch or connected external braking resistor circuit.
What are the primary causes of A79B alarm?
Primary root causes include damaged external brake resistor elements, shorted conductors at terminals R+ and R-, shorted chopper IGBTs, and using resistors below minimum Rmin limits.
How do I troubleshoot and correct A79B alarm?
Disconnect terminals R+ and R-, test resistor ohms against drive minimum specifications, perform a 500V DC insulation megger test, and check the chopper semiconductor with a multimeter.