The A2019 alarm in the ABB ACS355 variable frequency drive indicates that an automated Motor Identification (ID) Run routine is currently active. The drive temporarily suppresses normal process speed commands while executing specialized magnetic saturation and stator resistance mapping to optimize vector control performance.
During this operational phase, the inverter firing circuit modulates the output IGBTs with micro-current pulses and rotational torque vectors to measure stator resistance, rotor time constants, and leakage inductance without tripping overcurrent limits. Because this is an intentional calibration cycle initiated by parameter 9910 (ID RUN), the DC bus voltage remains stabilized while output terminals U2, V2, and W2 energize the motor windings. Standard external start/stop signals and analog reference speed inputs are bypassed until mathematical modeling completes.
What Causes A2019 in ABB ACS355?
- Parameter
9910(MOTOR ID RUN) has been intentionally set to1(ON) orSTANDSTILLby an engineer during initial commissioning. - A technician updated motor nameplate specifications in parameter group
99, requiring automated flux vector calibration. - The drive completed a firmware restore or factory macro reset, prompting a mandatory baseline motor identification sequence.
- An automated commissioning script via DriveWindow Light or external PLC initiated calibration before permitting normal line operation.
Step-by-Step Troubleshooting and Solutions
- Do not interrupt main incoming 3-phase power at terminals
L1,L2, andL3; allow the drive between 10 seconds and 3 minutes to conclude the automated identification process. - Monitor the integrated or assistant control panel display until the warning symbol disappears and the drive transitions from
A2019to a ready state (displaying output frequency0.0 Hz). - Verify motor nameplate data in parameters
9905(MOTOR NOM VOLT),9906(MOTOR NOM CURR), and9907(MOTOR NOM FREQ) to prevent calculation errors. - If the ID run fails or aborts with an overcurrent fault, disconnect load coupling, perform a
1000 Vmotor insulation megger test on phasesU2,V2, andW2, and restart the routine in standstill mode.
Preventative Maintenance to Avoid A2019 Faults
Because A2019 is an operational status alert rather than an electrical fault, avoid unnecessary re-triggers by verifying that motor commissioning parameters are permanently saved to internal flash memory. Schedule routine thermal inspections on terminal blocks U2, V2, and W2, and always confirm uncoupled mechanical rotation when running high-precision rotating ID routines.
Frequently Asked Questions (FAQs)
What is the meaning of A2019 alarm in ABB ACS355 drive?
The A2019 alarm signifies that the drive is currently executing an automated motor identification run to calculate stator resistance and flux characteristics for optimal vector control.
What are the primary causes of A2019 alarm?
This alarm is triggered whenever parameter 9910 is set to initiate motor identification or when new motor nameplate ratings are entered during commissioning.
How do I troubleshoot and correct A2019 alarm?
Allow the drive to complete the routine uninterrupted until the alarm clears automatically, and verify that motor nameplate values in parameter group 99 are accurate.