64FF fault in ABB ACS560 drive

Home/ABB/ABB ACS560 drive/64FF fault in ABB ACS560 drive

The 64FF event in the ABB ACS560 drive indicates an informational fault reset action initiated via a control interface. This system notice confirms that an active trip state was cleared, allowing the drive firmware to re-enable its internal gating sequence.

When code 64FF registers in the event logger, the inverter processing unit registers that a trip condition was acknowledged and cleared either locally or remotely. The intermediate DC bus capacitor bank remains charged to approximately 1.35 × Vline, and the main control board resets its fault latch, returning the drive logic from a lock-out condition to ready-to-run status. No hardware protection threshold was violated by this event; instead, it provides a timestamped trace confirming whether the reset originated from digital input logic, fieldbus communications, the integrated control panel, or commissioning software.

What Causes 64FF in ABB ACS560?

  1. An operator manual reset command issued directly from the assistant control panel keypad.
  2. A rising-edge pulse received on a designated digital input configured for fault reset in parameter 31.11 Fault reset selection.
  3. A control word bit transition transmitted over Modbus RTU or industrial fieldbus communication protocols.
  4. A software command executed through the ABB Drive composer PC commissioning tool.
  5. Automated PLC auxiliary logic triggering repetitive reset commands following an unrectified primary trip.

Step-by-Step Troubleshooting and Solutions

  1. Inspect the drive event log history prior to timestamp 64FF to locate the underlying trip code that triggered the initial shutdown.
  2. Audit digital control terminals DI1 through DI6 to ensure external 24V DC control circuits are not intermittently pulsing parameter 31.11.
  3. Review automation PLC sequencing logic to ensure automated reset pulses are not masking genuine motor or inverter stress conditions.
  4. Verify serial communications on terminals 485-1 and 485-2 to confirm the Modbus control word Bit 3 is functioning as designed.

Preventative Maintenance to Avoid 64FF Faults

Maintain clean logging architecture by synchronizing the real-time clock on the control panel, ensuring all upstream faults are physically resolved before issuing reset commands, and avoiding automated continuous reset cycling from supervisory control systems.

Frequently Asked Questions (FAQs)

What is the meaning of 64FF fault in ABB ACS560 drive?

The 64FF entry is an informational event code recorded whenever an active trip condition is successfully cleared by a user command or remote interface.

What are the primary causes of 64FF fault?

This entry is triggered by manual keypresses on the keypad, digital input pulses, serial communications commands, or Drive composer connection requests.

How do I troubleshoot and correct 64FF fault?

Review the event history preceding this notice to locate and resolve the actual underlying root fault that initiated the original shutdown.