The A591 warning signifies active initialization of the internal drive hardware architecture within the ABB ACS560. It indicates that the embedded controller is enumerating internal power modules, analog interfaces, and memory tables prior to enabling run status.
Upon power application, the ACS560 supervisor logic performs a low-level handshake across internal communication buses. This verification sequence interrogates the digital signal processor (DSP), current measurement transducers, gate driver logic, and non-volatile memory caches. Warning A591 prevents motor start commands from triggering inverter PWM switching before hardware health parameters and calibrated offsets are fully established. If the internal sequence hangs or encounters unreadable configuration registers, this warning remains visible on the control panel display.
What Causes A591 in ABB ACS560?
- Standard power-up initialization where the drive hardware setup is establishing normal runtime registers (auxiliary code
0000). - First-time system commissioning where internal flash memory is configured with frame-specific power tables (auxiliary code
0001). - Slow stabilization of internal
24V DCcontrol power rails causing prolonged microprocessor boot loops. - Interrupted parameter backups or incomplete firmware flashes executed via the
Drive composerPC interface. - Hardware interface communication faults across internal ribbon connections between the control unit and the power module.
Step-by-Step Troubleshooting and Solutions
- Observe the auxiliary code on the control display: if
0000or0001is active, wait2 to 5 minutesfor background setup to finish. - Check incoming main phase balance on terminals
L1, L2, L3with a calibrated multimeter to verify voltage symmetry within±3%. - Refrain from toggling digital inputs or sending run requests across Modbus while initialization is actively communicating.
- Perform a cold restart by disconnecting mains supply power, waiting until the DC bus indicator LED discharges below
50V DC, and repowering. - If warning
A591fails to clear after multiple reboots, useDrive composerto re-download the original system configuration or contact ABB service.
Preventative Maintenance to Avoid A591 Faults
Ensure reliable uninterruptible control supply, maintain clean control board environments free of moisture or conductive carbon particles, and never cut drive power during active parameter save operations.
Frequently Asked Questions (FAQs)
What is the meaning of A591 fault in ABB ACS560 drive?
The A591 alarm indicates that internal drive hardware setup and component initialization sequences are currently in progress.
What are the primary causes of A591 fault?
It is caused by normal startup calibration, initial hardware configuration, low incoming control voltage, or incomplete parameter write operations.
How do I troubleshoot and correct A591 fault?
Allow the automated setup routine to complete, verify steady incoming line voltage, and perform a controlled power reboot if the state locks up.