Inovance CS710 Crane Drive Fault Codes & Diagnostic Guide
Complete fault code directory, crane trip alarm causes, and step-by-step troubleshooting procedures for the Inovance CS710 crane-dedicated AC drive series. Search or filter through the complete fault code directory below.
Power Range
0.4 – 450 kW (0.5 – 600 HP)
Supply Voltage
380–480V AC (3-Phase)
Control Modes
Closed-Loop Vector (FVC) & SVC
Operator Interface
LED / LCD Control Panel / InoDriveShop
Complete Inovance CS710 Crane Drive Fault Code Directory
Use the search box in the table below to quickly find your code (e.g., type Err02, Err04, or Overcurrent).
| Fault Code and Meaning | Cause and Remedy |
|---|---|
| Er102 Overcurrent during acceleration | Cause:
Remedy:
|
| Er103 Overvoltage during deceleration | Cause:
Remedy:
|
| Er104 Overvoltage at constant speed | Cause:
Remedy:
|
| Er105 Overcurrent during acceleration | Cause:
Remedy:
|
| Er106 Overvoltage during deceleration | Cause:
Remedy:
|
| Er107 Overvoltage at constant speed | Cause:
Remedy:
|
| Er108 Control power fault | Cause:
Remedy:
|
| Er109 Undervoltage fault | Cause:
Remedy:
|
| Er110 Drive overload | Cause:
Remedy:
|
| Er111 Motor overload | Cause:
Remedy:
|
| Er112 Input phase loss | Cause:
Remedy:
|
| Er114 IGBT overheat | Cause:
Remedy:
|
| Er115 Built-in braking unit overloaded | Cause:
Remedy:
|
| Er117 Contactor fault | Cause:
Remedy:
|
| Er118 Current detection fault | Cause:
Remedy:
|
| Er119 Motor auto-tuning fault | Cause:
Remedy:
|
| Er120 Encoder fault | Cause:
Remedy:
|
| Er123 Short circuit to ground | Cause:
Remedy:
|
| Er125 Output phase loss | Cause: 1. The cables connecting the drive and the motor are abnormal. 2. The three-phase outputs of the drive are unbalanced when the motor is running. 3. The drive board is faulty. 4. The IGBT module is faulty. Remedy:
|
| Er137 Abnormal frequency direction | Cause: The direction of the frequency reference is reverse to the direction of the motor feedback frequency. Remedy:
|
| Er138 Abnormal frequency following | Cause: There is large deviation between the frequency reference and the motor feedback frequency. Remedy:
|
| Er140 Pulse-by-pulse current limiting fault | Cause: 1. The load is too heavy or rotors of the motor are blocked. 2. The power rating of the drive is too low. Remedy:
|
| Er*41 Brake release fault | Cause: The input brake release feedback signal is incorrect. For details, see description of b6.08. Remedy:
|
| Er*42 Brake applying fault | Cause: The input brake applying feedback signal is incorrect. For details, see description of b6.08. Remedy:
|
| Er*43 Shaft-cooling motor low-speed running timeout | Cause: For details, see description of b0.00 and b0.01. Remedy:
|
| Er*44 Forward and reverse RUN commands valid simultaneously | Cause: The drive detects forward and reverse RUN commands simultaneously. Remedy:
|
| Er*45 Joystick not reset | Cause: The drive detects the RUN command or input frequency reference signal at power-on. Remedy:
|
| Er*46 Process card communication fault | Cause: Communication between the drive and process card (CS70CF*) is abnormal. Remedy:
|
| Er*47 CANlink communication fault | Cause: 1. The CANlink extension card does not work normally. 2. The communication cable does not work normally. Remedy:
|
| Er*48 Communication error | Cause: 1. The computer does not work normally. 2. The communication cable does not work normally. 3. Communication parameters in group bd are not set properly. Remedy:
|
| Er*49 Parameter read-write error | Cause: The EEPROM chip is damaged. Remedy:
|
| Er*50 External input fault | Cause: DI function 6 is valid. Remedy:
|
| Er*51 Function code error | Cause: 1. A function parameter is not set properly. 2. The EEPROM storage chip is faulty. Remedy:
|
How to Clear & Reset Inovance CS710 Drive Faults
- Keypad Reset: Press the red STOP/RES key on the LED/LCD operating panel while in a tripped status. Ensure the mechanical hoist brake is securely clamped and the crane motion has halted.
- Digital Input Reset (DI): If an input terminal (DI1 to DI8) is configured to function 9 (Fault reset) in parameter group F4-00 to F4-07, pulse the remote push-button or crane cabin reset switch.
- Crane PLC / Fieldbus Interface: Send a reset command by writing Bit 7 to control word address 2000H over Modbus RTU, Profibus-DP, Profinet, or CANopen networks.
- InoDriveShop PC Software: Connect via the front diagnostic port using a dedicated RS485 communication adapter, open InoDriveShop, inspect active hoist faults, and select “Fault Reset”.
- Power Cycle: Disconnect the incoming 3-phase line supply. Wait 5 to 10 minutes until the CHARGE lamp is completely extinguished and internal capacitors bleed down, then restore main power.
⚠️ Crane Safety & High-Voltage Warning:
Before resetting faults or servicing hoist drives, ensure the suspended load is safely landed on the ground and mechanical fail-safe brakes are fully locked. Always measure DC bus voltage across terminals (+) and (-) with a calibrated multimeter to confirm it is below 36VDC before opening terminal enclosures on the Inovance CS710 drive.