Inovance IS620N drive

Home / Inovance / Inovance IS620N drive

Inovance IS620N Servo Drive Fault Codes & Diagnostic Guide

Complete fault code reference directory, trip alarm causes, and step-by-step troubleshooting procedures for the Inovance IS620N single-axis EtherCAT AC servo drive series. Search or filter through the complete fault code directory below.

Single-Axis EtherCAT Servo Drive Power: 0.1 to 7.5 kW (100W – 10 HP) CiA 402 Motion Profile
Power Range 0.1 – 7.5 kW (100W – 10 HP)
Supply Voltage 1-Ph 220V / 3-Ph 220V & 380V
Bus Protocol EtherCAT (CoE / CiA 402)
Feedback / Bandwidth 20/23-Bit Encoder (1.2 kHz)

Complete Inovance IS620N Drive Fault Code Directory

Use the search box in the table below to quickly find your code (e.g., type Er.101, Er.601, or Overcurrent).

Fault Code and MeaningCause and Remedy
Er.101
Parameter abnormal

Cause:

The total number of parameters changes or values in group 2002h exceed limits (often after software update). Other causes include: Control power voltage drops, instantaneous power failure, excessive parameter writing frequency, or the servo drive is faulty.



Remedy:

  • Restore the default setting (2002-20h = 1), and write the parameters again.

  • Check control power (L1C, L2C). Ensure voltage is within specs (220V drive: 198-264V; 380V drive: 342-484V).

  • Increase power capacity or replace with large-capacitance power supply.

  • If power failure occurred during storage: Power on again, restore default settings, and write parameters again.

  • If writing frequency limit exceeded: Change the parameter writing method (from host controller) and write again.

  • If software upgraded: Set servo drive/motor model again and restore default settings.

  • If fault persists after restoring defaults multiple times, replace the servo drive.


Er.102
Programmable logic configuration fault

Cause:

The FPGA software version and the MCU software version do not match, or the hardware is damaged resulting in communication failure.



Remedy:

  • View MCU (2001-01h) and FPGA (2001-02h) versions via operating panel.

  • Contact Inovance technical support to update software to make versions match.

  • If fault persists after power cycling, replace the servo drive.


Er.103
FPGA software version too early

Cause:

The FPGA version in 2001-02h is earlier than 0112.0 (when MCU is 0101.7 or later).



Remedy:

  • Update the software to make the versions match.

  • If the fault persists after power cycling, replace the servo drive.


Er.104
Programmable logic interruption fault

Cause:

Access to MCU or FPGA times out. (Internal fault codes can be viewed in 200B-2Eh).



Remedy:

  • If the fault persists after the servo drive is powered off and on several times, replace the servo drive.


Er.105
Internal program abnormal

Cause:

The total number of parameters is abnormal at EEPROM reading/writing operation, or data range is abnormal (often after software update).



Remedy:

  • Check causes according to the method of Er.101.

  • Restore the default setting (2002-20h = 1), and power on the system again.

  • If fault persists, replace the servo drive.


Er.108
Parameter storage fault

Cause:

Parameter values cannot be written to or read from EEPROM.



Remedy:

  • Modify a parameter, power on the drive again, and check if modification is saved.

  • If modification is not saved and fault persists after power cycling, replace the servo drive.


Er.120
Product model matching fault

Cause:

The motor model and drive model do not match or parameter setting is incorrect.



Remedy:

  • Set 200D-01h (Motor SN) correctly according to the motor nameplate.

  • View drive model in 2001-03h and ensure it matches the nameplate.

  • Use matching products according to the Servo System Configuration.


Er.121
Invalid S-ON command

Cause:

When some auxiliary functions are used, a redundant S-ON signal is given.



Remedy:

  • Turn off the S-ON signal from the host controller.


Er.122
Product matching fault in absolute position mode

Cause:

The motor does not match in absolute position mode or the motor SN is set incorrectly.



Remedy:

  • Set 200D-01h (Motor SN) correctly according to the motor nameplate.

  • Ensure the motor is a multi-turn absolute encoder motor.


Er.130
Different DIs allocated with the same function

Cause:

The same function is allocated to different DIs, the DI function No. exceeds limits, or the function is not supported.



Remedy:

  • Allocate group 2003h and 2007h parameters correctly (ensure no duplicate non-zero functions).

  • Turn control power off/on or toggle S-ON/Reset to effect changes.

  • Restore default settings (2002-20h = 1) if MCU program is updated.

  • Do not set a DI function No. not included in the DI/DO function definitions table.


Er.131
DO function No. exceeding the number of functions

Cause:

The DO function No. exceeds the number of DO functions.



Remedy:

  • Restore the default setting (2002-20h = 1), and power on the system again.


Er.136
Data check error or no parameter stored in the motor ROM

Cause:

When reading parameters from encoder ROM, the drive detects no parameters are saved or values are inconsistent. Mismatch between drive and motor.



Remedy:

  • Use matched servo drive and servo motor (Inovance IS620N series).

  • Use the recommended encoder cable. Ensure reliable connection.

  • Check signals PS+, PS-, +5V, and GND at both ends of cable.

  • Never bundle encoder cable and power cables together.

  • If fault persists after power cycling, replace the servo drive.


Er.200
Overcurrent 1

Er.201
Overcurrent 2

Cause:

Er.200: Any phase feedback current is larger than the overcurrent threshold.

Er.201: Hardware overcurrent is detected.



Remedy:

  • Check reference input timing (wait for "rdy"). Add reference filter time or increase accel/decel time.

  • Check Regenerative Resistor:

    • If internal (2002-1Ah=0): Check jumper between P and D.

    • If external (2002-1Ah=1/2): Check wiring between P and C. Verify resistance values.



  • Fasten loose power cables or motor UVW cables.

  • Check grounding: Measure insulation resistance between UVW and PE (should be MΩ-level). Replace motor if insulation is poor.

  • Check for short circuits or burrs in motor cables; connect correctly.

  • Check if motor is damaged (unbalanced resistance). Replace if necessary.

  • Carry out gain adjustment if motor oscillates or makes shrill noise.

  • Check encoder cable (aging, corrosive, loose). Re-weld or replace.

  • If fault persists after cables are disconnected and power cycled: Replace the servo drive.


Er.207
Shaft D/Q current overflow

Cause: Abnormal current feedback results in overflow of the internal register of the servo drive.



Remedy:

  • If the fault persists after the servo drive is powered off and powered on again for several times, replace the servo drive.


Er.208
FPGA sampling operation timeout

Cause: Internal sampling or communication timeout (Check internal sub-code 200B-2Eh).



Remedy:

  • Subcode 1208 (MCU timeout): The internal chip is damaged. Replace the servo drive.

  • Subcode 2208 (Encoder timeout): Check encoder wiring, connectors, and cable length. Use shielded twisted pair. Replace servo motor if encoder is faulty.

  • Subcode 3208 (Current sampling timeout): Check for large equipment generating interference. Separate heavy current from light current. Replace servo drive if chip is damaged.

  • Subcode 4208 (AD conversion timeout): High-accuracy AI interference. Use twisted shielded cables and shorten distance.

  • Subcode 0208 (FPGA timeout): Remove the preceding causes listed above.


Er.210
Output to-ground short-circuit

Cause: The servo drive detects motor phase current or bus voltage abnormal during self-check at power-on.



Remedy:

  • Disconnect motor cables and measure if drive power cables are shorted to ground. Re-connect or replace cables.

  • Measure insulation resistance between UVW and PE. Replace motor if insulation is poor.

  • Remove power cables; if fault persists after power cycling, replace the servo drive.


Er.220
Phase sequence incorrect

Cause: After angle auto-tuning, the UVW phase sequence is inconsistent with that of the motor.



Remedy:

  • Perform the wiring again and then perform angle auto-tuning.


Er.234
Runaway

Cause: Torque reference direction is reverse to speed feedback, or speed feedback is reverse to reference in position/speed mode.



Remedy:

  • Check UVW sequence and connect cables according to the correct sequence.

  • If Er.234 occurs immediately at power-on (initial phase error): Power on the servo drive again.

  • Ensure matching Drive and Motor (Check parameters like 2000-01h). Correct motor model and encoder settings.

  • Check encoder cable wiring (aging/loose). Re-weld or replace.

  • Vertical Axis: Reduce load, improve stiffness, or shield this fault (if safety permits).


Er.400
Main circuit overvoltage

Cause: DC bus voltage exceeds threshold (220V drive > 420V; 380V drive > 760V).



Remedy:

  • Measure input voltage. Replace or adjust power supply to be within specifications.

  • If supply is unstable/lightning affected: Connect a surge suppressor.

  • Check Braking/Regenerative Resistor:

    • Internal: Check jumper P and D.

    • External: Check wiring P and C. Select resistor with correct resistance/power. Set parameters 2002-1Bh and 2002-1Ch.



  • If resistance is too large/absorption insufficient: Connect new external resistor of recommended value between P and C.

  • If abrupt accel/decel: Increase acceleration/deceleration time.

  • If bus voltage sampling deviation is large (measured vs displayed): Contact Inovance technical support.

  • If fault persists after power cycling: Replace the servo drive.


Er.410
Main circuit undervoltage

Cause: The DC bus voltage between P⊕ and ⊖ is lower than the overvoltage threshold.

(220V drive < 200V; 380V drive < 380V).

Potential causes include unstable power supply, instantaneous power failure, voltage drops, or phase loss.



Remedy:

  • Measure input voltage (RST) to ensure it is within specifications (220V drive: 198-264V; 380V drive: 342-484V).

  • Improve power capacity if voltage drops during operation.

  • Check if single-phase power is being used for a three-phase drive (Phase loss).

  • Check if main circuit wiring is correct and reliable.

  • If fault persists after power cycling multiple times, replace the servo drive.


Er.420
Main circuit phase loss

Cause: Phase loss occurs on the three-phase servo drive, or input power is unbalanced.

Could be due to loose cables, single-phase power applied to 3-phase drive, or faulty drive.



Remedy:

  • Check if power cables (RST) are connected securely.

  • Replace cables if damaged.

  • If using single-phase input on 0.75kW drives, set parameter 200A-01h = 2 (Inhibit faults).

  • If input voltage is too low or unbalanced, adjust power capacity.

  • If fault persists, replace the servo drive.


Er.430
Control power undervoltage

Cause: The voltage of the control power (L1C, L2C) is below the threshold (190V for 220V drive; 380V for 380V drive).



Remedy:

  • Check if control power is cut off or if instantaneous failure occurred.

  • Measure input voltage of L1C and L2C cables to ensure they meet specifications.

  • Check for poor contact in control power cables; reconnect or replace them.

  • Improve power capacity if voltage is unstable.


Er.500
Motor overspeed

Cause: The actual speed of the servo motor exceeds the overspeed threshold.

Issues may include incorrect UVW phase sequence, incorrect threshold settings, or input reference being too high.



Remedy:

  • Check UVW cabling phase sequence and connect correctly.

  • Check overspeed threshold (200A-09h). Reset according to mechanical requirement.

  • Position Mode: Decrease gear ratio or position reference increment.

  • Speed Mode: Decrease target velocity or gear ratio.

  • Torque Mode: Set speed limit smaller than overspeed threshold.

  • Adjust gain or mechanical conditions if motor overshoots.

  • If fault persists after power cycling, replace servo drive.


Er.510
Pulse output overspeed

Cause: When pulse output function is used, the output pulse frequency exceeds the hardware limit (1 MHz).



Remedy:

  • Decrease parameter 2005-12h (Encoder frequency-division pulses).

  • Ensure output pulse frequency is below the limit within the required speed range.


Er.610
Servo drive overload

Cause: Heat accumulation of the servo drive reaches the fault level.

Commonly caused by poor wiring, heavy load, or improper gain settings.



Remedy:

  • Check wiring between servo drive, motor, and encoder. Use recommended cables.

  • Check if load is too heavy (Average load ratio > 100%). Use larger capacity drive if needed.

  • Increase acceleration/deceleration time.

  • Adjust gain if motor vibrates or produces abnormal noise.

  • Verify servo drive/motor model settings (2000-06h and 2001-03h).

  • Eliminate mechanical binding/locking factors.


Er.620
Motor overload

Cause: Heat accumulation of the motor reaches the fault level.



Remedy:

  • Reduce load or increase acceleration/deceleration time.

  • Check for mechanical interference causing heavy load.

  • Check if motor brake is released correctly.

  • Replace servo drive if fault persists after cooling and restart.


Er.630
Motor rotor locked

Cause: The actual motor speed is lower than 10 RPM but the torque reference reaches the limit for a specific duration.



Remedy:

  • Check for Phase Loss or incorrect UVW sequence. Correct wiring.

  • Check for broken encoder cables or UVW cables.

  • Check running reference (pulse counter/speed ref) in commissioning software.

  • Eliminate mechanical locking factors blocking the motor.


Er.650
Heatsink overheat

Cause: Temperature of the power module is higher than the protection threshold.



Remedy:

  • Measure ambient temperature; improve cooling conditions.

  • Ensure proper clearance between drives.

  • Check if fan is working; replace drive if fan is damaged.

  • Do not reset overload faults repeatedly without cooling down (wait 30s).

  • If fault persists 5 minutes after power-off restart, replace servo drive.


Er.731
Encoder battery failed

Cause: The battery voltage of the absolute encoder is lower than 3.0 V.



Remedy:

  • Check battery connection.

  • Set 200D-15h = 1 to remove the fault (after fixing connection).

  • Replace with a new battery of matching voltage.


Er.733
Encoder multi-turn counting error

Cause: The encoder multi-turn counting is incorrect.



Remedy:

  • Set 200D-15h = 2 to remove the fault.

  • If fault persists after power-on, replace the motor.


Er.735
Encoder multi-turn counting overflow

Cause:

The encoder multi-turn counting overflows (detected when 2002-02h = 1).



Remedy:

  • Set 200D-15h = 1 to remove the fault.


Er.740
Encoder interference

Cause:

The encoder Z signal suffers interference, resulting in too large change of corresponding electrical angle of Z signal.



Remedy:

  • Check the encoder wiring and connect the cable correctly.

  • Re-connect the encoder cable securely if loose.

  • Check for on-site vibration or damage to the encoder.

  • Use cables recommended by Inovance (STP cable). Do not bundle motor and encoder cables together.

  • Ensure servo motor and drive are well grounded.

  • Replace the encoder cable.

  • Replace the motor if the encoder is faulty.


Er.770
External encoder scale fault

Cause:

When fully closed-loop or customized pulse input is used, the level difference between signals (A+/A-, B+/B-, Z+/Z-) does not meet requirements.



Remedy:

  • If frequency-division output is not forbidden: Set H05-38 to 2.

  • Measure level difference; adjust level to meet specifications (>2V).

  • Note: When using external encoder without Z signal, pull up Z+ to above 2V and make Z- grounded.


Er.A33
Encoder data abnormal

Cause:

Internal parameters of the encoder are abnormal.



Remedy:

  • Check connection of the encoder cable (incorrect connection, wire break, or poor contact).

  • Separate motor cables and encoder cables if bundled.

  • Power cycle the drive; if fault persists, replace the servo motor.


Er.A34
Encoder communication check abnormal

Cause:

After power-on, an error occurs in reading the rotor's initial phase information from the 2500-PPR incremental encoder.



Remedy:

  • Ensure the servo drive model matches the motor model (Check nameplates).

  • Check if encoder cable is broken or insecure; replace or reconnect securely.


Er.A35
Z signal lost

Cause:

Z signal of the 2500-PPR incremental encoder gets lost or AB signal edges change simultaneously.



Remedy:

  • Use a new encoder cable and connect correctly.

  • Replace the servo motor if the fault persists after cable replacement.


Er.B00
Position deviation excess

Cause:

The position deviation is larger than the setting of 6065h in position control mode.



Remedy:

  • Check UVW wiring/phase sequence; correct wiring or replace cables.

  • Eliminate mechanical factors locking the motor rotor.

  • Adjust position loop and speed loop gains (manually or auto-tuning).

  • Decrease position reference increment or gear ratio.

  • Increase the value of 6065h (Following error window).

  • If position reference is not 0 but feedback is 0, replace drive or motor.


Er.B01
Position reference excess

Cause:

The position reference increment of adjacent synchronization periods is excessive.



Remedy:

  • Decrease the target position reference increment.

  • Assign the current position value to the target position (607Ah) before mode switchover or servo ON.

  • Set synchronization offset parameter to 0 (if host is AM600) or check communication.

  • Check that maximum motor speed/profile speed settings are not too small.


Er.B02
Position deviation exceeding threshold in fully closed-loop

Cause:

The absolute value of position deviation in fully closed-loop exceeds 200F-09h.



Remedy:

  • Check UVW wiring and connections; repair if broken or incorrect.

  • Eliminate mechanical factors causing rotor lock.

  • Adjust servo drive gains (manual or auto-tuning).

  • Decrease position reference increment or gear ratio (CSP, PP, HM modes).

  • Increase the value of 200F-09h.

  • If position reference is not 0 but feedback is 0, replace drive or motor.


Er.B03
Electronic gear ratio setting exceeding limit

Cause:

Any electronic gear ratio exceeds limit.



Remedy:

  • Set the gear ratio within the required range.

  • Reset the fault or power on the system again.


Er.B04

Parameter setting error with fully closed-loop function

Cause:


When the fully closed-loop function is used and the position reference source is internal position reference, switchover between internal encoder feedback and external encoder feedback is enabled (Check if 200F-01h = 2).



Remedy:



  • In fully closed-loop mode, when the position reference source is internal position reference, only external encoder feedback can be used.

  • Ensure 200F-01h is set to 1.


Er.110

Setting error of frequency-division pulse output

Cause:


When using the encoder frequency-division output function (2005-27h = 0), the number of encoder frequency-division pulses does not match the threshold determined by the encoder specification.



Remedy:



  • For incremental encoders: frequency-division pulses per revolution must not exceed encoder PPR (20-bit = 1048576 P/r, 2500-PPR = 10000 P/r).

  • For absolute encoders: frequency-division pulses must not exceed 1/4 of the encoder resolution.

  • Re-set the frequency-division pulses per revolution in 2005-12h according to the specification.


Er.601

Homing timeout

Cause:


When using the homing function, home is not found within the time set in 2005-24h.



Remedy:



  • If home switch fails: Check DI function FunIN.31 (HomeSwitch) and wiring. Manually change DI logic and observe 200B-04h.

  • If search time is too short: Increase the time set in 2005-24h.

  • If search speed is too small: Check distance to home switch and increase 6099-01h (Speed during search for switch).

  • If home switch setting is improper: Check if limit signals at two sides are active simultaneously. Set the position of the hardware switch properly.


Er.730

Encoder battery warning

Cause:


The battery voltage of the absolute encoder is lower than 3.0 V.



Remedy:



  • Measure the battery voltage.

  • Use a new battery of matching voltage.


Er.900

DI emergency braking

Cause:


The logic of DI (including hardware DI and VDI) allocated with FunIN.34: EmergencyStop is valid/triggered.



Remedy:



  • Check the running mode.

  • Clear the DI braking signal on the prerequisite of ensuring safety.


Er.909

Motor overload warning

Cause:


Accumulative heat of 60Z series 200 W and 400 W motors reaches the warning threshold.



Remedy:



  • Wiring issues: Connect wirings correctly according to the diagram. Use cables recommended by Inovance.

  • Load too heavy: Use a servo drive of larger capacity/matching motor. Reduce load and increase acceleration/deceleration time.

  • Accel/Decel too frequent: Increase the acceleration/deceleration time.

  • Improper Gain: Check for vibration/noise and adjust the gain.

  • Wrong Model Set: View servo drive nameplate and set the correct model in 2001-03h.

  • Locked-rotor (Mechanical): Eliminate mechanical factors causing heavy load.

  • Drive Faulty: Replace the servo drive.


Er.920

Regenerative resistor overload

Cause:


The accumulative heat of the regenerative resistor exceeds the setting value.



Remedy:



  • Connection issues: Check cable connection. If resistance is ∞, replace cable or resistor. If using internal resistor, check jumper between P⊕ and D.

  • Incorrect Setting (2002-1Ah): Set 2002-1Ah correctly (1 for External natural, 2 for External forced cooling).

  • Resistor too large: Select proper resistor according to specification table (6.1.7).

  • Wrong Resistance Setting: Set 2002-1Ch according to the actual resistance used.

  • Input Voltage High: Replace or adjust power supply to match specifications (220V or 380V ranges).

  • Inertia too large: Select larger external resistor and set 2002-1Bh correctly. Or select larger servo drive.

  • High Speed/Duty: Reduce load, increase accel/decel time, or increase motor running period.

  • Drive Faulty: Replace the servo drive.


Er.922
Resistance of the external regenerative resistor too small

Cause:


The resistance of the external regenerative resistor (2002-1Ch) is smaller than the permissible minimum resistance (2002-16h).



Remedy:

  • Measure the resistance of the external regenerative resistor between terminals P⊕ and C.

  • Check if the measured value is smaller than 2002-16h.

  • If yes, connect an external regenerative resistor matching the servo drive specifications.

  • Set 2002-1Ch (Resistance of external regenerative resistor) to the actual value.


Er.939
Motor power cable breaking

Cause:


The actual phase current is smaller than 10% of the rated current, and motor speed is small while internal torque reference is very large.



Remedy:

  • Check connection of motor power cables.

  • Reconnect the motor power cables.

  • Replace the cables with new ones if necessary.


Er.941
Parameter modification taking effect only after power-on again

Cause:


Parameters with the effective condition "power-on again" have been modified.



Remedy:

  • Power off and then power on the servo drive again.


Er.942
Parameter storage too frequent

Cause:


The number of parameters modified and stored to EEPROM exceeds 200 times.



Remedy:

  • Check if the host controller performs frequent and fast parameter modification.

  • For parameters that do not need to be stored in EEPROM, set 200C-0Eh to 0 before operation.


Er.950
Positive limit switch warning

Cause:


The logic of the Digital Input (DI) allocated with FunIN.14 (P-OT Positive limit switch) is valid.



Remedy:

  • Check the running mode.

  • Ensure safety, then send a reverse reference or rotate the motor to move away from the limit switch.

  • Make the logic of the DI with the positive limit switch function invalid.


Er.952
Negative limit switch warning

Cause:


The logic of the Digital Input (DI) allocated with FunIN.15 (N-OT Negative limit switch) is valid.



Remedy:

  • Check the running mode.

  • Ensure safety, then send a reverse reference or rotate the motor to move away from the limit switch.

  • Make the logic of the DI with the negative limit switch function invalid.


Er.980
Encoder internal fault

Cause:


An encoder algorithm error occurred.



Remedy:

  • Power off and power on the servo drive several times.

  • If the warning persists, the encoder is faulty. Replace the servo motor.


Er.990
Power input phase loss warning

Cause:


Single-phase power is applied to a three-phase drive (allowed for <1kW), but the warning (200A-01h) is enabled.



Remedy:

  • If connected to three-phase power: Rectify wiring (treat as Er.420 Power cable phase loss).

  • If single-phase input is intended: Set 200A-01h to 0 to disable the warning.


Er.998
Homing mode setting incorrect

Cause:


The homing mode set in 0x6098h is incorrect or not supported (15/16/31/32).



Remedy:

  • View the setting of 6098h.

  • Set 6098h correctly.


Internal Faults

Er.602: Angle auto-tuning failure

Er.220: Phase sequence incorrect

Er.A40: Motor auto-tuning failure

Er.111: Internal parameter abnormal

Cause:


Various internal system failures.



Remedy:

  • Contact Inovance for technical support.


Er.D09
Software upper/lower limit setting incorrect

Cause:


The lower limit of software position is larger than the upper limit.



Remedy:

  • View settings of 607D-01h and 607D-02h.

  • Set 607Dh correctly.

  • Ensure 607D-1h < 607D-2h.


Er.D10
Home offset setting incorrect

Cause:


The home offset is set outside the software position lower/upper limit.



Remedy:

  • View settings of 607D-01h, 607D-02h, and 607Ch.

  • Set 607D correctly.

  • Ensure 607D-01h ≤ 607Ch ≤ 607D-02h.


Er.E08
Synchronization loss

Cause:


The master’s synchronization signal is abnormal during communication.



Remedy:

  • Use shielded twisted pair cables for communication.

  • Ensure the servo drive is well grounded.

  • Check the Ethernet port and network connection status.

  • Identify synchronization performance of the host.

  • Increase the permissible interruption loss times (200C-2Dh) of the slave.

  • Check the network status switchover program of the host.


Er.E11
The XML configuration file is not burnt

Cause:


The device configuration file is missing, or the slave ID scanned by the host is empty.



Remedy:

  • Burn the device configuration file.

  • If the issue persists, replace the servo drive.


Er.E12
Network initialization failure

Cause:


FPGA firmware not burnt, equipment configuration file not burnt, or hardware fault.



Remedy:

  • Check if 2001-02h is 01XX.Y; burn FPGA firmware if needed.

  • Burn the equipment configuration file.

  • Replace the servo drive.


Er.E13
Synchronization cycle setting incorrect

Cause:


The synchronization cycle is not an integral multiple of 125 us or 250 us.



Remedy:

  • Modify the synchronization cycle to an integral multiple of 125 us or 250 us.


Er.E15
Synchronization cycle error being large

Cause:


The synchronization cycle error exceeds the threshold.



Remedy:

  • Measure synchronization cycle via oscilloscope.

  • Increase 200C-2Dh and test.

  • If fault persists, set 200C-2Ch to 2.


How to Clear & Reset Inovance IS620N Drive Faults

  1. EtherCAT Master Reset (PLC): Transition Bit 7 (Fault Reset) from 0 to 1 in the CiA 402 standard Controlword object (6040h) via Beckhoff TwinCAT, Omron Sysmac, or your host EtherCAT master controller.
  2. Front Operating Keypad Reset: Press and hold the MODE or SET key on the drive’s built-in 5-digit LED front panel while in the alarm display menu to acknowledge and clear resettable non-critical alarms.
  3. Digital Input (DI) Alarm Reset: Pulse the multi-function digital input terminal assigned to function ALM-RST (Alarm Reset), configured in parameter group H03 (Input Terminal Selection) or object 2003h.
  4. InoServoShop PC Commissioning Tool: Connect your PC via the front USB interface (CN5), open InoServoShop, view the detailed trip history in parameter group H02 (Fault Log / 2002h), and click Fault Reset.
  5. Mains & Control Power Cycle: For hard hardware trips and encoder disconnect errors (e.g., Er.101, Er.120, Er.740), switch off primary mains power (R, S, T) and control power supply (L1C, L2C). Wait at least 5 minutes until the charge indicator LED completely turns off before reapplying power.
⚠️ High-Voltage Electrical Safety Warning: Always verify with a calibrated digital multimeter that intermediate DC bus voltage measures strictly below 36VDC across terminals [(+)] and [(-)] before disconnecting servo motor power lines (U, V, W), servicing external regenerative braking resistors, or opening terminal housings on the Inovance IS620N servo drive.