Inovance SV660F Servo Drive Fault Codes & Diagnostic Guide
Complete fault code reference directory, trip alarm causes, and step-by-step troubleshooting procedures for the Inovance SV660F single-axis PROFINET AC servo drive series. Search or filter through the complete fault code directory below.
Power Range
0.05 – 7.5 kW (50W – 10 HP)
Supply Voltage
1-Ph 230V / 3-Ph 400V AC
Bus Protocol
PROFINET RT / IRT (PROFIdrive)
Feedback / Loop
23-Bit Encoder & 4.5 kHz Loop
Complete Inovance SV660F Drive Fault Code Directory
Use the search box in the table below to quickly find your code (e.g., type Er.201, Er.740, or Overcurrent).
| Fault Code and Meaning | Cause and Remedy |
|---|---|
| E108.0 Parameter write error Parameter values cannot be written to EEPROM. | Cause: An error occurs during parameter-writing. Remedy:
|
| E108.1 Parameter read error Parameter values cannot be read from EEPROM. | Cause: The parameter-read operation is abnormal, and the system indicates an EEPROM read failure. Remedy:
|
| E108.2 EEPROM write check error The check on the data written in EEPROM failed. | Cause: An error occurs during parameter-writing. Remedy:
|
| E108.3 EEPROM read check error The check on the data read in EEPROM failed. | Cause: An error occurs during parameter-reading. Remedy:
|
| E110.0 Frequency-division pulse output setting error The frequency-division output setpoint (H05.17) exceeds the encoder resolution. | Cause: The number of frequency divisions (quadrupled) exceeds the motor revolutions. Remedy:
|
| E121.0 Duplicate S-ON command A redundant S-ON signal is sent when some auxiliary functions are used. | Cause: The external S-ON signal is active when servo drive is enabled internally. Remedy:
|
| E122.0 Multi-turn absolute encoder setting error The motor does not match the absolute position mode or the motor code is set improperly. | Cause: The motor does not match the absolute position mode or the motor code is set incorrectly. Remedy:
|
| E510.0 Frequency division output overspeed The single-channel output pulse frequency exceeds the frequency upper limit allowed by the hardware (4 MHz). | Cause:
Remedy:
|
| E550.2 External switchover wait warning Incorrect task block switching. | Cause: The external warning must be kept to allow current block to continue operating. Remedy:
|
| E600.0 Inertia auto-tuning failure Vibration cannot be suppressed, values fluctuate, or load issues. | Cause:
Remedy:
|
| E601.0 Homing warning Homing time exceeds the setpoint. | Cause:
Remedy:
|
| E601.1 Homing switch error The homing switch is set improperly. | Cause: The home switch is set improperly (e.g., limit signals at both sides activated simultaneously with home signal). Remedy:
|
| E601.2 Homing method setting error The homing method value is too large. | Cause: The homing method value is too large. Remedy:
|
| E730.0 Encoder battery warning The voltage of the absolute encoder battery is lower than 3.0 V. | Cause: The voltage of the absolute encoder battery is lower than 3.0 V. Remedy:
|
| E900.0 DI emergency braking The DI terminal allocated with DI function 34 (Emergency Stop) is active. | Cause: The DI function 34 (EmergencyStop) is triggered. Remedy:
|
| E902.0 DI setting invalid DI function parameters are set to invalid values. | Cause: DI (DI1...DI5) function parameters are set to invalid values. Remedy:
|
| E902.1 DO setting invalid DO function parameters are set to invalid values. | Cause: DO (DO1...DO3) function parameters are set to invalid values. Remedy:
|
| E902.2 Invalid setting for torque reach DO parameters set for torque reach are invalid. | Cause: The value of H07.22 is lower than or equal to the value of H07.23. Remedy:
|
| E908.0 Model identification failure Model identification check code error. | Cause:
Remedy:
|
| E908.1 Inverter model setting mismatch The inverter model is set improperly. | Cause:
Remedy:
|
| E920.0 Regenerative resistor overload The accumulative heat of the regenerative resistor exceeds the set value. | Cause:
Remedy:
|
| E922.0 Resistance of external regenerative resistor too small H02.27 is lower than H02.21 (permissible min. resistance). | Cause: When an external resistor is used, its resistance is lower than the minimum allowed. Remedy:
|
| E924.0 Regenerative transistor overtemperature Estimated temperature is higher than H0A.18. | Cause: The regenerative transistor temperature exceeds the threshold defined by H0A.49. Remedy:
|
| E941.0 Parameter modifications activated at next power-on Parameters modified require a restart. | Cause: The parameters modified are those whose "Effective time" is "Next power-on". Remedy:
|
| E942.0 Parameter saved frequently The number of parameters modified at a time exceeds 200. | Cause: Too many parameters are modified and saved to EEPROM (H0C.13 = 1) at a brief interval. Remedy:
|
| E950.0 Forward overtravel warning DI function 14 (P-OT) effective or software limit reached. | Cause:
Remedy:
|
| E952.0 Reverse overtravel warning DI function 15 (N-OT) effective or software limit reached. | Cause:
Remedy:
|
| E958.0 Reverse position reference overtravel in process segment position mode Reverse direction position reference overtravel. | Cause: Position reference is less than the value of H22.06 when motor runs reversely in process segment mode. Remedy:
|
| E980.0 Encoder algorithm error An encoder algorithm error occurs. | Cause: An internal fault occurs on the encoder. Remedy:
|
| EA41.0 Torque fluctuation compensation failure The torque compensation fails. | Cause: The torque compensation fails. Remedy:
|
| E101.0 Parameter error in H02 and above | Cause: 1. Control circuit power supply voltage drops instantaneously. 2. Instantaneous power failure while saving parameters. 3. Excessive write operations within a certain period. 4. Software update caused parameter limit overflow. 5. Servo drive is faulty. Remedy:
|
| E101.1 Parameter error in group H00/H01 | Cause: Parameter values in H00/H01 exceed the upper/lower limit (often after software update or initialization). Remedy:
|
| E101.2 Address error in read/write operation | Cause: Total number of parameters changed after software update, leading to address error. Remedy:
|
| E102.0 FPGA communication establishment error | Cause: Communication between MCU and FPGA cannot be established. Remedy:
|
| E102.1 FPGA initialization start error | Cause: FPGA cannot start / FPGA failed. Remedy:
|
| E102.8 FPGA and MCU version mismatch | Cause: The software versions of MCU and FPGA are inconsistent. Remedy:
|
| E104.1 MCU running timeout (MCU break down) | Cause: Access to MCU timed out due to FPGA failure, communication handshaking error, or coprocessor access timeout. Remedy:
|
| E104.2 Current loop operation timeout (FPGA break down) | Cause: MCU torque interrupt scheduling time is abnormal (FPGA failure or handshaking error). Remedy:
|
| E104.4 MCU command update timeout | Cause: Encoder communication time set improperly or command calculation time is too long. Remedy:
|
| E120.0 Unknown encoder model | Cause: 1. Motor or drive code does not exist. 2. Power rating of motor does not match servo drive. Remedy:
|
| E120.1 Unknown motor model | Cause: The motor model defined by H00.00 is abnormal or does not exist. Remedy:
|
| E120.2 Unknown drive model | Cause: H01.10 is incorrect (drive model detection failed). Remedy:
|
| E120.5 Motor and drive current mismatch | Cause: The internal scale value is abnormal (rated output of drive is far higher than motor). Remedy:
|
| E120.6 FPGA and motor model mismatch | Cause: FPGA software version and H00.00 mismatch, or encoder not supported. Remedy:
|
| E120.7 Model check error | Cause: Model parameter CRC check failed. Remedy:
|
| E120.8 Junction temperature parameter check error | Cause: Junction temperature parameter CRC check failed. Remedy:
|
| E122.1 Different DIs assigned with the same function | Cause: 1. Multiple DIs assigned with same function. 2. DI function No. exceeds maximum allowed. Remedy:
|
| E122.2 Different DOs assigned with the same function | Cause: The DO function No. exceeds the maximum number allowed. Remedy:
|
| E122.3 Upper limit in the rotation mode invalid | Cause: The upper limit of the mechanical single-turn position exceeds 2^31 in absolute position rotation mode. Remedy:
|
| E122.4 Different VDIs assigned with the same function | Cause: 1. The same function is assigned to different VDIs. 2. VDI function No. exceeds maximum allowed. Remedy:
|
| E122.5 DI and VDI assigned with the same function | Cause: Two or more DIs and VDIs are assigned with the same function No. Remedy:
|
| E122.8 Small lower limit of the rotation mode | Cause: The lower limit of the mechanical single-turn position (modal axis modulus) is less than 1. Remedy:
|
| E126.0 Process segment number error | Cause: The process segment number is not 1000 or any value from 0 to 15. Remedy:
|
| E126.1 Process segment internal operation mode error | Cause: The technology segment operation mode is not 0, 1, 2, 3, 7, or 8. Remedy:
|
| E126.2 Position reference type error in process segment | Cause: The position reference type is not 00 (Absolute) or 10 (Incremental). Remedy:
|
| E136.0 Encoder ROM motor parameter check error | Cause: 1. Servo drive/motor model mismatch. 2. Encoder ROM parameter check error or no parameters saved. 3. Servo drive is faulty. Remedy:
|
| E136.1 Encoder ROM motor parameter read error | Cause: 1. Encoder cable connections incorrect or loosened. 2. Ambient vibration causing looseness. 3. Servo drive is faulty. Remedy:
|
| E136.2 Torque ripple compensation data check error | Cause: Data check error. Remedy:
|
| E150.0 STO safety state applied | Cause: Two 24V inputs are disconnected simultaneously, triggering STO function. Remedy:
|
| E150.1 STO input state abnormal | Cause: The single-channel input of STO is ineffective. Remedy:
|
| E150.2 Buffer 5 V voltage detection error. The MCU monitors the 5 V power supply of the PWM Buffer. | Cause: The 5 V voltage supplied to the STO Buffer is abnormal due to undervoltage or overvoltage. Remedy:
|
| E150.3 STO input circuit hardware diagnosis failure. Short circuit on upstream optocoupler of STO. | Cause: Short circuit occurs on the upstream optocoupler of STO1 or STO2. Remedy:
|
| E150.4 PWM buffer hardware detection failure. Error on PWM Buffer IC during initialization. | Cause: STO Buffer power-on test error. Remedy:
|
| E201.0 Phase-P overcurrent. Excessively high current flows through the positive pole of the DC-AC circuit. | Cause: 1. Gains set improperly (oscillation). 2. Encoder wired improperly, aging, or loose. 3. Servo drive is faulty. 4. Overcurrent on regenerative resistor. Remedy:
|
| E201.1 Phase-U overcurrent. Current higher than threshold collected in phase-U. | Cause: 1. Motor cables in poor contact, grounded, or short-circuited. 2. The motor is damaged. Remedy:
|
| E201.2 Phase-V overcurrent. Current higher than threshold collected in phase-V. | Cause: 1. Motor cables in poor contact, grounded, or short-circuited. 2. The motor is damaged. Remedy:
|
| E201.4 Phase-N overcurrent. Excessively high current flows through the negative pole of the DC-AC circuit. | Cause: 1. Gains set improperly (oscillation). 2. Encoder wired improperly or aging. 3. Regen resistor resistance too small or shorted. 4. Abrupt acceleration during braking. 5. Servo drive is faulty. Remedy:
|
| E206.0 Switching frequency abnormal. | Cause: 1. Motor control malfunction. 2. Switch-on times of inverting circuit is abnormal. Remedy:
|
| E208.2 Encoder communication timeout. FPGA detected communication timeout with encoder. | Cause: 1. Drive fails to receive data for 3 consecutive cycles. 2. Cable loose, too long, or interference. 3. Faulty encoder. Remedy:
|
| E208.4 FPGA current loop operation timeout. Operating time exceeds interval threshold. | Cause: FPGA operation timeout / Internal fault code H0b.45 = 4208. Remedy:
|
| E210.0 Output short-circuited to ground. Abnormal phase current or bus voltage during power-on self-test. | Cause: 1. Power cables (U/V/W) shorted to ground. 2. Motor shorted to ground. 3. Servo drive faulty. 4. Motor speed too high during detection. Remedy:
|
| E234.0 Runaway. Torque/Speed reference direction is reverse to feedback direction. | Cause: 1. Phase sequence of U/V/W incorrect. 2. Interference signal causes error in initial phase detection. 3. Encoder model wrong or wired improperly. 4. Gravity load too large (vertical axis). 5. Improper stiffness settings (vibration). Remedy:
|
| E320.0 Regenerative resistor overload. | Cause: Accumulative heat of regenerative resistor exceeds thermal capacity. Remedy:
|
| E320.1 Braking resistor surface temperature too high. | Cause: The braking resistor surface temperature is too high. Remedy:
|
| E400.0 Main circuit overvoltage. DC bus voltage exceeds threshold. | Cause: DC bus voltage between P⊕ and N⊖ is too high. (220V drive threshold: 420V / 380V drive threshold: 760V). Remedy:
|
| E410.0 Main circuit undervoltage | Cause: 1. The power supply of the main circuit is unstable or power failure occurs. Remedy:
Cause: 2. Instantaneous power failure occurs. Remedy:
Cause: 3. The power voltage drops during running. Remedy:
Cause: 4. A three-phase servo drive is connected to a single-phase power supply (Phase Loss). Remedy:
Cause: 5. The servo drive is faulty (Bus voltage reading error). Remedy:
|
| E410.1 Main circuit de-energized (Phase Loss) | Cause: 1. The power supply is disconnected during operation. Remedy:
Cause: 2. Drive faulty (Internal voltage check). Remedy:
Cause: 3. Wiring issue. Remedy:
|
| E420.0 Main circuit phase loss | Cause: 1. The three-phase input cables are connected improperly. Remedy:
Cause: 2. A single-phase power supply is used for a three-phase servo drive. Remedy:
Cause: 3. Power supply unbalanced or voltage too low. Remedy:
|
| E420.1 Main circuit PL signal detection error | Cause: 1. Three-phase input cables connected improperly. Remedy:
Cause: 2. Single-phase used / Unbalanced supply. Remedy:
|
| E430.0 Control circuit power supply undervoltage | Cause: 1. The control power supply of servo drives (size C/D/E) is unstable or fails. Remedy:
Cause: 2. Control power supply cables in poor contact. Remedy:
|
| E500.0 Motor overspeed | Cause: 1. The phase sequence of motor cables is wrong. Remedy:
Cause: 2. H0A.08 (Overspeed threshold) is set improperly. Remedy:
Cause: 3. The input reference exceeds the overspeed threshold. Remedy:
Cause: 4. The motor speed overshoots. Remedy:
Cause: 5. The servo drive is faulty. Remedy:
|
| E500.1 Speed feedback overflow | Cause: 1. FPGA internal speed overflows. Remedy:
Cause: 2. The motor speed overshoots. Remedy:
|
| E500.2 FPGA position feedback pulse overspeed | Cause: Communication error occurred between boards of the drive. Remedy:
|
| E550.0 Initial operation block number not exist | Cause: The block number designated by PLC is outside range (0-15) or set to "Invisible". Remedy:
|
| E550.1 Relative/absolute attribute set improperly | Cause: The relative/absolute attribute of positioning or fixed stopper commands set improperly (bit8–bit11 of task mode is 0 or 1). Remedy:
|
| E550.9 Fixed stopper beyond the window | Cause: The position feedback fluctuation exceeds the monitoring window (H28.64) after the fixed stopper is found. Remedy:
|
| E551.1 Program block stop exception | Cause: The switchover condition for the last block is not "stop". Remedy:
|
| E551.3 Jump block not exist | Cause: The block number designated by the jump task does not exist. Remedy:
|
| E602.0 Angle auto-tuning failure | Cause: The data fed back by the encoder is abnormal (unusual jitter). Remedy:
|
| E602.2 U/V/W phase sequence reversed | Cause: Incorrect UVW wiring is detected during angle auto-tuning. Remedy:
|
| E605.0 Motor speed too high upon S-ON | Cause: The motor speed exceeds the rated speed when the servo drive is switched on. Remedy:
|
| E620.0 Motor overload | Cause: The accumulative heat of the motor reaches the fault threshold. Possible causes:
Remedy:
|
| E625.0 Brake abnormality enabled | Cause: The brake fails when it is released. Remedy:
|
| E626.0 Brake abnormality disabled | Cause: The brake fails when it closes. Remedy:
|
| E630.0 Motor rotor locked over-temperature | Cause: Motor speed is lower than 10rpm but torque reference reaches limit for time defined by H0A.32. Remedy:
|
| E640.0 IGBT over-temperature | Cause: The IGBT temperature reaches the fault threshold defined by H0A.18. Remedy:
|
| E640.1 Flywheel diode overtemperature | Cause: The temperature of the flywheel diode reaches the fault threshold defined by H0A.18. Remedy:
|
| E650.0 Heatsink overtemperature | Cause: The temperature of the servo drive power module is higher than the overtemperature threshold. Remedy:
|
| E660.0 Motor overtemperature | Cause: The temperature of the air-cooled motor is too high. Remedy:
|
| E661.0 STune failure | Cause: During STune operation, the gain drops to the lower limit (Position/Speed loop gain < 5, Model loop gain < 10). Remedy:
|
| E662.0 ETune failure | Cause: Resonance occurred during ETune operation cannot be suppressed. Remedy:
|
| E663.0 ITune failure | Cause: Resonance occurred during ITune operation cannot be suppressed. Remedy:
|
| E664.0 Resonance too strong | Cause: Resonance occurs on the servo system and the torque fluctuation amplitude is higher than the value of H09.54. Remedy:
|
| E731.0 Encoder battery failure | Cause: The voltage of the absolute encoder battery is lower than 2.9V. Remedy:
|
| E733.0 Encoder multi-turn counting error | Cause: An encoder multi-turn counting error occurs (Encoder faulty). Remedy:
|
| E735.0 Encoder multi-turn counting overflow | Cause: A multi-turn counting overflow occurs on the absolute encoder (Forward revolutions > 32767 or Reverse > 32768). Remedy:
|
| E740.0 Absolute encoder communication timeout | Cause: Communication timeout occurs on the absolute encoder. Remedy:
|
| E740.2 Absolute encoder error | Cause: A communication error occurs on the RX side of the encoder. Remedy:
|
| E740.3 Absolute encoder single-turn calculation error | Cause: An internal fault occurs on the encoder (Encoder is faulty). Remedy:
|
| E740.6 Encoder data write error | Cause: An error occurs when writing the position offset after angle auto-tuning. Remedy:
|
| E760.0 Encoder overtemperature | Cause: The temperature of the absolute encoder is too high. Remedy:
|
| E765.0 Nikon encoder over-temperature or overspeed | Cause: Motor overtemperature. Remedy:
|
| E770.0 Fully-closed input phase A wire breakage | Cause: Fully-closed phase A input differential voltage wire breakage. Remedy:
|
| E770.1 Fully-closed input phase B wire breakage | Cause: Fully-closed phase B input differential voltage wire breakage. Remedy:
|
| E770.2 Fully-closed input phase Z wire breakage | Cause: Fully-closed phase Z input differential voltage wire breakage. Remedy:
|
| EA33.0 Encoder read/write check error | Cause: Internal parameters of the encoder are abnormal (or cable disconnected/loose). Remedy:
|
| EB00.0 Position deviation too large | Cause: Position deviation is larger than setpoint of 6065h. Potential causes: Phase loss, disconnected cables, mechanical stall, low gain, or reference increment too large. Remedy:
|
| EB00.1 Position deviation overflow | Cause: The position deviation is too large. Remedy:
|
| EB01.0 Position reference increment too large | Cause: Pulse reference increment exceeds threshold three times consecutively. Remedy:
|
| EB01.1 Individual position reference increment too large | Cause: The target position increment is too large. Remedy:
|
| EB01.2 Position reference increment too large continuously | Cause: The target position increment is too large (Continuous). Remedy:
|
| EB01.3 Command overflow | Cause: The target position is still in the process of transmission when the servo limit or software position limit signal is activated and the 32-bit upper/lower limit is reached. Remedy:
|
| EB01.4 Target position beyond upper/lower limit | Cause: The target position exceeds the upper/lower limit of the unit position in the single turn absolute mode. Remedy:
|
| EB02.0 Position deviation exceeding threshold in fully closed-loop | Cause: The absolute value of position deviation in fully closed-loop mode exceeds the value of H0F.08. Causes include phase loss, disconnected cables, mechanical stalling, low drive gain, high input pulse frequency, or hardware faults. Remedy:
|
| EB03.0 Electronic gear ratio beyond the limit - H05.02 | Cause: The electronic gear ratio exceeds the limit: (0.001–4000 x Encoder resolution/10000). Remedy:
|
| EB03.1 Electronic gear ratio beyond the limit - Electronic gear ratio 1 | Cause: The group 1 electronic gear ratio exceeds the limit: (0.001–4000 x Encoder resolution/10000). Remedy:
|
| EB03.2 Electronic gear ratio beyond the limit - Electronic gear ratio 2 | Cause: The group 2 electronic gear ratio exceeds the limit: (0.001–4000 x Encoder resolution/10000). Remedy:
|
| EE03.0 Communication timeout | Cause: Communication timeout occurred after switching to the running state. Communication frame present, but drive is waiting. Remedy:
|
| EE03.1 Communication abnormal | Cause: The communication chip is not functioning properly (faulty), and the check times out. Remedy:
|
| EE08.0 PLC synchronization lost | Cause: The SYNC signal is turned off when the PROFINET network is in the OP state. Bit10 of control word changes. Remedy:
|
| EE08.1 PLC stopped | Cause: The PLC stopped during synchronous communication. Remedy:
|
| EE08.7 Abnormal heartbeat | Cause: The heartbeat is abnormal during synchronous communication. Remedy:
|
| EE08.8 No network connection during synchronous communication | Cause: The network is not connected during synchronous communication. Remedy:
|
| EE08.9 LAN cable disconnected | Cause: The LAN cable is disconnected during synchronous communication. Remedy:
|
| EE09.0 Software position limit setting error | Cause: The lower limit of the software position limit is equal to or larger than the upper limit. Remedy:
|
| EE09.1 Home setting error | Cause: The home offset exceeds the upper/lower limit of the software position limit or mechanical limit. Remedy:
|
| EE09.2 Gear ratio beyond the limit | Cause: The electronic gear ratio exceeds the limit. Remedy:
|
| EE09.3 Homing mode setting error | Cause: MCU does not receive synchronization signal. Causes include improper sync clock config, inverse IN/OUT connection, damaged slave IC, or damaged MCU pins. Remedy:
|
| EE09.5 PDO mapping beyond the limit | Cause: The mapping objects in TPDO or RPDO exceeds 40 bytes. Remedy:
|
| EE11.0 ESI check error | Cause: PROFINET communication failed to load the XML file. XML not downloaded or drive faulty. Remedy:
|
| EE11.1 EEPROM read failure | Cause: Communication with external EEPROM failed. Remedy:
|
| EE11.2 EEPROM update failure | Cause: Communication is normal but message in EEPROM is wrong or lost. Remedy:
|
| EE11.3 ESI and drive mismatch | Cause: The XML file does not match the drive model. Remedy:
|
| EE12.0 Parallel port detection error | Cause: The internal chip is faulty. Remedy:
|
| EE15.0 Synchronization cycle error too large | Cause: The synchronization cycle error of the controller exceeds the threshold. Remedy:
|
| EE16.0 MCU and ESC communication error | Cause: MCU and ESC communication timed out. Remedy:
|
| EE18.0 PN device name missing | Cause: The communication is faulty, leading to device name loss. Remedy:
|
| EE20.0 Continuous position reference not supported | Cause: Continuous position reference is set for telegram 111 relative positioning. Remedy:
|
| Internal Faults (E602.0, E220.0, EA40.0, E111.0) | Cause: Internal errors (Angle auto-tuning, Phase sequence, Parameter auto-tuning, Internal parameter). Remedy:
|
How to Clear & Reset Inovance SV660F Drive Faults
- PROFINET Master Reset (PLC): Transition Bit 7 (Fault Acknowledge / Reset) from
0to1in the PROFIdrive standard Control Word 1 (STW1) via Siemens TIA Portal or host motion controller. - Drive Front Keypad Reset: Press and hold the MODE / SET key on the drive’s 5-digit LED front panel while in the alarm display menu to acknowledge and clear resettable non-fatal faults.
- Digital Input (DI) Alarm Reset: Pulse the multi-function digital input terminal assigned to function ALM-RST (Alarm Reset), mapped in parameter group H03 (Input Terminal Selection).
- Inovance InoServoShop Software: Connect via the front commissioning port, open InoServoShop PC software, inspect the waveform and fault snapshot in parameter group H02 (Fault History), and click Fault Reset.
- Control & Mains Power Cycle: For critical system trips or encoder safety alarms (such as Er.101 or Er.740), switch off primary main power (L1, L2, L3) and 24VDC control supply. Wait at least 5 minutes until the charge indicator turns off completely before restoring power.
⚠️ High-Voltage Electrical Safety Warning:
Always verify with a calibrated digital multimeter that intermediate DC bus voltage measures strictly below 36VDC across terminals [(+)] and [(-)] before disconnecting servo motor power cables (U, V, W), servicing regenerative brake leads, or opening terminal housings on the Inovance SV660F servo drive.