Lenze 8200 Motec Drive Fault Codes & Diagnostic Guide
Complete fault code reference directory, trip error messages, and step-by-step troubleshooting procedures for the Lenze 8200 Motec decentralized frequency inverter series. Search or filter through the complete fault code directory below.
Power Range
0.25 – 7.5 kW (0.33 – 10 HP)
Supply Voltage
1~ 230V / 3~ 400–500V AC
Control Modes
V/f (Linear/Quad) & SLVC
Operator Interface
Keypad XT / GDC Software
Complete Lenze 8200 Motec Drive Fault Code Directory
Use the search box in the table below to quickly find your code (e.g., type OC1, OU, OH, or Overcurrent).
| Fault Code and Meaning | Cause and Remedy |
|---|---|
| nDEr (0) No fault | Cause: - Remedy: - |
| CCr (71) System failure | Cause:
Remedy:
|
| CE0 (61) Communication error on AIF | Cause: Faulty transmission of control commands via AIF. Remedy:
|
| CE1 (62) Communication error on CAN-IN1 (sync control) | Cause: CAN-IN1 object receives faulty data or communication is interrupted. Remedy:
|
| CE4 (65) BUS-OFF | Cause: Controller has received too many faulty telegrams via the system bus and has been disconnected. Remedy:
|
| LP1 (32/182) Error in motor phase | Cause:
Remedy:
|
| LU (-) DC bus undervoltage | Cause:
Remedy:
|
| OC1 (11) Short circuit | Cause:
Remedy:
|
| OH (50) Heatsink temperature > +85 °C | Cause: Ambient temperature is too high. Remedy:
|
| OH4 (54) Controller overtemperature | Cause: Controller too hot inside. Remedy:
|
| Pr5 (79) Internal fault | Cause: EEPROM is defective. Remedy:
|
| Sd5 (85) Open circuit - analog input 1 | Cause: Current at analog input < 4 mA at setpoint range 4 ... 20 mA. Remedy:
|
How to Clear & Reset Lenze 8200 Motec Drive Faults
- Keypad Reset: Press the STOP / RESET key on the plug-in Keypad XT (or diagnostic handheld terminal). If the drive is operating in local manual mode, ensure the start/run condition is inactive before executing the reset.
- Terminal Input Reset (TRIP-RESET): Apply a low-to-high signal transition (0 → 1 edge pulse) on the digital input terminal assigned to the TRIP-RESET function (configured via code C0410 on input terminals E1 through E4).
- Global Drive Control (GDC) PC Tool: Connect your PC to the drive via the diagnostic interface / LECOM optical or RS232/RS485 adapter, open Lenze Global Drive Control (GDC / GDC easy), and click “TRIP-Reset” in the drive status window.
- Fieldbus Control Word: Write Bit 11 (TRIP-RESET) from
0to1in the automation control word across connected fieldbus modules (PROFIBUS-DP, CANopen, DeviceNet, or AS-Interface). - Mains Power Cycle: Switch off the main AC line power, wait until all diagnostic LEDs on the unit turn off completely (approx. 3 to 5 minutes to permit internal capacitor discharge), and reapply power.
⚠️ High-Voltage Electrical Safety Warning:
After switching off the mains power supply, wait at least 3 minutes for intermediate DC bus capacitors to discharge. Verify with a calibrated DC voltmeter that voltage across DC bus terminals (+UG and -UG) is below 50V DC before loosening housing screws, opening the IP65 enclosure cover, or touching power terminals (L1, L2, L3, PE, U, V, W).