Complete Lenze i550 motec Drive Fault Code Directory
Use the search box in the table below to quickly find your error code (e.g., type 2250, 2320, 3210, or Overcurrent).
| Fault Code and Meaning | Cause and Remedy |
|---|---|
| 2250 CiA: Continuous overcurrent (inside the device) | Cause: Classification: Error Remedy:
|
| 2320 Short circuit or earth leakage on motor side | Cause: Classification: Error Remedy:
|
| 2340 CiA: Short circuit (inside the device) | Cause: Classification: Error Remedy:
|
| 2350 CiA: i²*t overload (thermal state) | Cause: Classification: Error Remedy:
|
| 2382 Error - device utilization (Ixt) too high | Cause: Classification: Error Remedy:
|
| 2383 Warning - device utilization (Ixt) too high | Cause: Classification: Warning Remedy:
|
| 3120 Mains phase fault | Cause: Classification: Error Remedy:
|
| 3210 Error - DC bus overvoltage | Cause: Classification: Error Remedy:
|
| 3211 Warning: DC-bus overvoltage | Cause: Classification: Warning Remedy:
|
| 3220 Error - DC-bus undervoltage | Cause: Classification: Trouble Remedy:
|
| 3221 Warning: DC bus undervoltage | Cause: Classification: Warning Remedy:
|
| 3222 DC-bus voltage too low for switch-on | Cause: Classification: Warning Remedy:
|
| 4210 Error - power section overtemperature | Cause: Classification: Error Remedy:
|
| 4281 Warning - heatsink fan | Cause: Classification: Warning Remedy:
|
| 4310 Motor overtemperature | Cause: Classification: Error Remedy:
|
| 5112 24 V supply critical | Cause: Classification: Warning Remedy:
|
| 5180 24 V supply overload | Cause: Classification: Warning Remedy:
|
| 6280 Trigger/functions connected incorrectly | Cause: Classification: Trouble Remedy:
|
| 7180 Motor overcurrent | Cause: Classification: Error Remedy:
|
| FF06 Motor overspeed | Cause: Classification: Error Remedy:
|
| FF37 Automatic start disabled | Cause: Classification: Error Remedy:
|
How to Clear & Reset Lenze i550 motec Drive Faults
- Digital Input Reset (DI2 / DI1): By default, an active error can be reset by applying a HIGH signal to digital input 2 (parameter 0x2631:004 – Error reset). Alternatively, drop and re-apply the start signal on digital input 1 (parameter 0x2631:002) once the fault root cause is resolved and any parameter-defined blocking time has elapsed.
- Lenze EASY Starter Engineering Tool: Connect your PC via the integrated micro-USB diagnostic interface or optional WLAN module. Open Lenze EASY Starter, navigate to the Diagnostics tab, and click the “Reset” button to clear the fault buffer.
- Lenze SMART Keypad Mobile App: If equipped with the external WLAN diagnostic module, open the Lenze SMART Keypad app on your iOS or Android mobile device, connect to the drive’s local network, and trigger a fault reset directly from the diagnostics screen.
- Ethernet / Fieldbus Control Word: Set bit 7 (Fault Reset / Acknowledge) from `0` to `1` in the CiA 402 control word over PROFINET, EtherCAT, EtherNet/IP, Modbus TCP, or IO-Link.
- Mains Power Cycle: Switch off incoming AC supply power. Wait at least 3 minutes until the DRIVE status LEDs (blue RDY and red ERR) completely turn off and internal DC bus capacitors discharge, then re-energize the inverter.
⚠️ High-Voltage Electrical Safety Warning:
Although the Lenze i550 motec features a rugged IP66 / NEMA 4X decentralized housing, dangerous intermediate DC bus voltage remains present after mains disconnection. Always isolate the AC mains line, wait at least 3 minutes, and verify using a calibrated multimeter that DC bus voltage is below 50V DC before opening connection covers, disconnecting plug-and-play connectors, or servicing motor leads.