Parker FL20 Drive Fault Codes & Diagnostic Guide
Complete fault code reference directory, trip alarm causes, and step-by-step troubleshooting procedures for the Parker FL20 series high-performance servo drive. Search or filter through the complete fault code directory below.
Power Range
0.1 – 37 kW (0.13 – 50 HP)
Supply Voltage
220V (1Ø/3Ø) & 380–440V AC (3Ø)
Control Modes
Position, Speed & Torque (Closed Loop)
Operator Interface
5-Digit LED Panel & PC Servo Software
Complete Parker FL20 Drive Fault Code Directory
Use the search box in the table below to quickly find your code (e.g., type Er-001, OVERCURRENT, or ENCODER).
| Fault Code and Meaning | Cause and Remedy |
|---|---|
| AL-01 Overcurrent | Cause: Main circuit wiring error, output short-circuit, internal short-circuit, interference, or damaged servo drive. Remedy:
|
| AL-02 Overvoltage | Cause: Input voltage is too high or load rotary inertia is too large. Remedy:
|
| AL-03 Undervoltage | Cause: Input voltage is low. Remedy:
|
| AL-04 Hardware fault | Cause: Hardware fault. Remedy:
|
| AL-05 Electric angle recognition error | Cause: Motor line sequence error. Remedy:
|
| AL-06 Overload | Cause: Servo motor or encoder wiring is bad, mechanical factors, electromagnetic brake not released, or heavy load. Remedy:
|
| AL-07 Overspeed | Cause: Servo motor rotary speed is higher than max speed. Remedy:
|
| AL-09 Large position control error | Cause: Connection error (U, V, W or encoder), low Servo Drive gain, or position pulse frequency is too high. Remedy:
|
| AL-10 Encoder fault | Cause: Disconnected encoder, locked-rotor, or Servo motor fault. Remedy:
|
| AL-11 Emergency stop | Cause: Logic of ESP input terminal not corresponding to connection, or hardware damage of ESP input. Remedy:
|
| AL-12 Servo drive overheat | Cause: Environment temperature too high, dirty radiator, foreign matter in fan, or fan damage. Remedy:
|
| AL-13 Input phase loss | Cause: Phase loss with input phase or use of single-phase power supply. Remedy:
|
| AL-14 Regenerative braking error | Cause: Wrong braking resistor parameter or continuous brake time is too long. Remedy:
|
| AL-16 Repeat setting of input terminal | Cause: Repeat setting of input terminal. Remedy:
|
| AL-17 Disconnected encoder cable | Cause: Disconnected encoder cable. Remedy:
|
| AL-18 Rotary inertia recognition fault | Cause: Rotary inertia recognition fault. Remedy:
|
| AL-19 Alarm of encoder battery | Cause: Alarm of encoder battery. Remedy:
|
| AL-20 Uninitialized E2ROM | Cause: Uninitialized E2ROM of servo motor. Remedy:
|
| AL-21 Large zero drift | Cause: Servo drive zero drift is too large. Remedy:
|
| AL-22 Z signal lost | Cause: Z signal is not detected after encoder rotates 3 times continuously. Remedy:
|
| AL-24 Encoder battery undervoltage | Cause: Encoder battery undervoltage. Remedy:
|
| AL-25 Motor overheat | Cause: Motor temperature is too high. Remedy:
|
| AL-26 Temperature detection circuit disconnected | Cause: Temperature detection circuit is disconnected. Remedy:
|
| AL-27 Overtravel | Cause: Overtravel alarm. Remedy:
|
| AL-28 E2ROM error | Cause: E2ROM error. Remedy:
|
| AL-29 Ground protection | Cause: Ground protection. Remedy:
|
| AL-30 Motor locked-rotor protection | Cause: Motor locked-rotor. Remedy:
|
| AL-31 Large mixed error of full closed-loop | Cause: Parameters not set properly, transmission part not fastened, connection errors, low drive gain, or pulse frequency too high. Remedy:
|
| AL-32 Synchronism error of gate bridge | Cause: Parameters not set, transmission not fastened, or wrong pulse received. Remedy:
|
| AL-33 Electric cam error | Cause: Electric cam data error. Remedy:
|
| AL-34 PLC command error | Cause: PLC command error. Remedy:
|
| AL-35 Home searching overtime | Cause: Home searching overtime. Remedy:
|
| AL-36 Parameter copy error | Cause: Parameter copy error. Remedy:
|
| AL-41 High-impedance state not detected | Cause: High-impedance state output is not detected after 8-core encoder is powered on. Remedy:
|
How to Clear & Reset Parker FL20 Drive Faults
- Keypad Reset: Use the 4-button front LED operator panel on the drive. When an alarm occurs, hold the MODE/SET key or enter the alarm parameter menu to clear the active fault state once the underlying cause is resolved.
- Digital Input Reset (ALM-RST): Assert the dedicated digital input pin assigned to Alarm Reset (ALM-RST) via the CN3 control I/O connector.
- PC Servo Tuning Software: Connect your PC via the CN1 serial port (RS485/RS232) or EtherCAT bus, launch the Parker servo diagnostic utility, and click Clear Alarm in the real-time monitoring window.
- Fieldbus / EtherCAT Control Word: Toggle the Fault Reset command bit (Bit 7 of standard CiA 402 control word) from `0` to `1` over the active EtherCAT or CANopen network.
- Power Cycle: Disconnect the main AC power input and control power. Wait until the red CHARGE LED indicator is completely extinguished (minimum 5 minutes for bus capacitors to discharge), then restore power.
⚠️ High-Voltage Electrical Safety Warning:
Observe the red CHARGING indicator LED on the front face of the drive. Always verify with a calibrated CAT III/CAT IV multimeter that DC link bus voltage measures strictly below 50VDC across terminals [+ / -] or [P / N] before inspecting motor wiring, encoder cables, or touching power terminals U, V, and W on the Parker FL20 servo drive.