Parker SLVD-N Drive Fault Codes & Diagnostic Guide
Complete fault code reference directory, trip alarm causes, and step-by-step troubleshooting procedures for the Parker Hannifin / SBC SLVD-N compact digital servo drive series. Search or filter through the complete fault code directory below.
Current Range
1 – 17 A (Peak up to 34 A)
Supply Voltage
200–230V AC (1/3-Phase)
Control Modes
Speed, Torque, Position & CANopen
Operator Interface
7-Segment Display & MotionWiz
Complete Parker SLVD-N Drive Fault Code Directory
Use the search box in the table below to quickly find your code (e.g., type 01, 03, or Overcurrent).
| Fault Code and Meaning | Cause and Remedy |
|---|---|
| 0 Drive OK | Cause: Drive is functioning normally. Remedy: None required. |
| 1 Over Voltage on the D.C. Link | Cause: Voltage on the DC link has exceeded limits. Remedy:
|
| 2 Under Voltage on the D.C. Link | Cause: Voltage on the DC link is too low. Remedy:
|
| 3 Over current | Cause: Excessive current detected. Remedy:
|
| 4 Resolver | Cause: Feedback signal issue. Remedy:
|
| 5 PTC motor alarm | Cause: Motor overheating or sensor fault. Remedy:
|
| 6 Drive Over Temperature | Cause: Drive unit is overheating. Remedy:
|
| 7 External alarm | Cause: Triggered by application (see the pico-PLC). Remedy:
|
| 8 Auxiliary alarm | Cause: Triggered by application (see the pico-PLC). Remedy:
|
| 10 check sum PLC | Cause: PLC data corruption or error. Remedy:
|
| 11 check sum parameters | Cause: Parameter data corruption. Remedy:
|
| 14 Brake overload | Cause: Braking resistance use overload. Remedy:
|
| 15 Default parameter | Cause: Parameter error. Remedy:
|
| 17 Calibration error | Cause: Calibration data invalid. Remedy:
|
| 22 Ambient over temperature | Cause: Ambient temperature too high. Remedy:
|
| 24 Braking transistor protection | Cause: Short-circuit braking resistance. Remedy:
|
| 25 Feedback speed error | Cause: Issue with speed feedback signal. Remedy:
|
| .... Limitation of current (I²T) | Cause: The drive goes in I²T mode due to an overload (it required more current that was available). Remedy:
|
How to Clear & Reset Parker SLVD-N Drive Faults
- MotionWiz PC Software: Connect via RS422/RS485 or CAN interface, launch Parker MotionWiz configuration software, and execute the “Reset Alarms” command (triggering command parameter b99.10).
- Digital Input Reset (Terminal Control): If assigned through the internal drive sequence or PLC program (e.g., digital inputs IN0–IN3 mapped to reset logic), apply a momentary 24V DC pulse to the assigned terminal.
- CANopen DS402 / SBCCAN Bus: Send a `0` to `1` transition on Bit 7 (Fault Reset) of the DS402 Controlword (Index 0x6040) or transmit an alarm reset telegram over the serial CAN bus.
- Parameter Reset (b99.10): Write a value of `1` to binary command parameter b99.10 to clear registers Pr23 (Active Alarm) and Pr24 (Last Alarm). Note: If a Checksum Error (Pr23 = 10 or 11) is active, reload factory defaults with b99.12 before resetting.
- Power Cycle: Disconnect both the main 230V AC line power and the 24V DC auxiliary control supply, wait at least 5 minutes until the front 7-segment display turns off and DC bus capacitors drop below 50VDC, then restore power.
⚠️ High-Voltage Electrical Safety Warning:
Always verify with a calibrated digital multimeter that the intermediate DC bus voltage measures strictly below 50VDC across power bus terminals [+] and [-] before opening covers, inspecting resolver/encoder wiring, or touching motor power terminals U, V, and W on the Parker SLVD-N servo drive.