Schneider ATV31 Drive Fault Codes & Diagnostic Guide
Complete fault code reference directory, trip alarm causes, and step-by-step troubleshooting procedures for the Schneider Electric Altivar 31 (ATV31) compact industrial drive series. Search or filter through the complete fault code directory below.
Power Range
0.18 – 15 kW (0.25 – 20 HP)
Supply Voltage
200–240V / 380–500V / 600V (1/3-Phase)
Control Modes
Sensorless Vector (SVC) & V/Hz Curve
Operator Interface
Integrated 4-Digit Display & Jog Dial
Complete Schneider ATV31 Drive Fault Code Directory
Use the search box in the table below to quickly find your code (e.g., type OCF, OHF, USF, or Overcurrent).
| Fault Code and Meaning | Cause and Remedy |
|---|---|
| bLF Brake sequence | Cause:
Remedy:
|
| CrF Capacitor load circuit | Cause: Load relay control fault or charging resistor damaged. Remedy:
|
| EEF EEPROM fault | Cause: Internal memory fault. Remedy:
|
| InF Internal fault | Cause:
Remedy:
|
| OCF Overcurrent | Cause:
Remedy:
|
| SCF Motor short-circuit | Cause:
Remedy:
|
| SOF Overspeed | Cause:
Remedy:
|
| tnF Auto-tuning fault | Cause:
Remedy:
|
| COF CAnopen fault | Cause: Interruption in communication on the CANopen bus. Remedy:
|
| EPF External fault | Cause: According to user. Remedy:
|
| LFF Loss of 4-20mA | Cause: Loss of the 4-20 mA reference on input AI3. Remedy:
|
| ObF Overvoltage during deceleration | Cause: Braking too sudden or driving load. Remedy:
|
| OHF Drive overheated | Cause: Drive temperature too high. Remedy:
|
| OLF Motor overload | Cause:
Remedy:
|
| OPF Motor phase loss | Cause:
Remedy:
|
| OSF Overvoltage | Cause:
Remedy:
|
| PHF Line phase failure | Cause:
Remedy:
|
| SLF Modbus fault | Cause:
Remedy:
|
| CFF Configuration fault | Cause: The current configuration is inconsistent. Remedy:
|
| CFI Configuration fault via serial link | Cause: Invalid configuration. The configuration loaded in the drive via the serial link is inconsistent. Remedy:
|
| USF Undervoltage | Cause:
Remedy:
|
How to Clear & Reset Schneider ATV31 Drive Faults
- Keypad Reset: Press the red STOP/RESET button directly on the front panel. Ensure the run command is removed before attempting to clear active fault trips.
- Logic Input Reset (LI): If configured in the [FAULT MANAGEMENT] (FLt-) menu under parameter [Fault reset] (rSt), toggle the assigned logic input terminal (LI1 through LI6) from 0 to 1.
- PowerSuite / SoMove Software: Connect via the RJ45 serial port using a PC connection cable (VW3A8106 / TCSMCNAM3M002P) to view active fault logs and initiate a software reset.
- Modbus / CANopen Control Word: Write Bit 7 (Fault Reset) from `0` to `1` in the Command Register (`CMD`) over the embedded Modbus RTU or CANopen interface.
- Mains Power Cycle: De-energize the incoming line power supply. Wait at least 15 minutes for the DC bus capacitors to discharge until the 4-digit LED display completely extinguishes, then reapply power.
⚠️ High-Voltage Electrical Safety Warning:
Always verify with a calibrated digital multimeter that intermediate DC bus voltage measures strictly below 42VDC across terminals [PA/+] and [PC/-] before inspecting motor lead connections, removing terminal covers, or touching terminals U, V, and W on the Schneider Altivar 31 (ATV31) drive.