Schneider ATV312 Solar Drive Fault Codes & Diagnostic Guide
Complete fault code reference directory, trip alarm causes, and step-by-step troubleshooting procedures for the Schneider Electric Altivar 312 Solar (ATV312 Solar) pumping drive series. Search or filter through the complete fault code directory below.
Power Range
0.18 – 15 kW (0.25 – 20 HP)
PV / Line Voltage
100–800V DC (PV) / 200–500V AC
Control Modes
Sensorless Vector, V/Hz & Solar MPPT
Operator Interface
Integrated 4-Digit Display / SoMove
Complete Schneider ATV312 Solar Drive Fault Code Directory
Use the search box in the table below to quickly find your code (e.g., type OCF, ObF, USF, or Overcurrent).
| Fault Code and Meaning | Cause and Remedy |
|---|---|
| bLF[NETWORK FAULT] | Cause:
Remedy:
|
| CrF[PRECHARGE FAULT] | Cause: Load relay control fault or charging resistor damaged. Remedy:
|
| EEF[EEPROM FAULT] | Cause: Internal memory detected fault. Remedy:
|
| IF1[INTERNAL FAULT] | Cause: Unknown range. Remedy:
|
| IF2[INTERNAL FAULT] | Cause:
Remedy:
|
| IF3[INTERNAL FAULT] | Cause: EEPROM detected fault. Remedy:
|
| IF4[INTERNAL FAULT] | Cause: Industrial EEPROM detected fault. Remedy:
|
| OCF[OVERCURRENT] | Cause:
Remedy:
|
| SCF[MOTOR SHORT CIRCUIT] | Cause:
Remedy:
|
| SOF[OVERSPEED] | Cause:
Remedy:
|
| CnF[NETWORK FAULT] | Cause: Communication detected fault on the communication card. Remedy:
|
| COF[CANopen FAULT] | Cause: Interruption in communication on the CANopen bus. Remedy:
|
| EPF[EXTERNAL FAULT] | Cause: Depending on user. Remedy:
|
| ILF[INTERNAL LINK FAULT] | Cause: Identification detected fault of the communication card by the drive. Remedy:
|
| LFF[LOSS OF 4-20 mA] | Cause: Loss of the 4-20 mA reference on input AI3. Remedy:
|
| ObF[OVERBRAKING] | Cause: Braking too sudden or Driving load. Remedy:
|
| OHF[DRIVE OVERHEAT] | Cause: Drive temperature too high. Remedy:
|
| OLF[MOTOR OVERLOAD] | Cause:
Remedy:
|
| OPF[MOTOR PHASE LOSS] | Cause:
Remedy:
|
| OSF[MAINS OVERVOLTAGE] | Cause:
Remedy:
|
| PHF [INPUT PHASE LOSS] | Cause: Drive incorrectly supplied or a fuse blown; Failure of one phase; Three-phase ATV312 used on a single-phase line supply; Unbalanced load; This protection only operates with the drive on load. Remedy:
|
| SLF [MODBUS FAULT] | Cause: Interruption in communication on the Modbus bus; Remote display terminal enabled ([HMI command] LCC = [Yes] YES) and terminal disconnected. Remedy:
|
| CFF [INCORRECT CONFIG.] | Cause: The current configuration is inconsistent; Addition or removal of an option. Remedy:
|
| CFI [INVALID CONFIG] | Cause: Invalid configuration; The configuration loaded in the drive via the serial link is inconsistent. Remedy:
|
| USF [UNDERVOLTAGE] | Cause: Insufficient line supply; Transient voltage dip; Damaged precharge resistor. Remedy:
|
| LL [Low Light] | Cause: Not enough power from photovoltaic arrays; Cloudy weather; Sunrise or sunset period. Remedy: Check the configuration of rPG/rIG and rPG2/rIG2 parameters. If there is enough sunshine:
If there is not enough sunshine:
|
| tF [Tank Full] | Cause: The tank is detected full. Remedy: If the tank is full:
If the tank is not full:
|
| tSF [Tank sensor detected fault] | Cause: Tank water sensor disconnected; Tank water sensor broken; Alarm threshold too low (LPtP value). Remedy:
|
| ULF [Underload detected fault] | Cause: Not enough water to pump; Pump blocked. Remedy:
|
How to Clear & Reset Schneider ATV312 Solar Drive Faults
- Keypad Reset: Press the red STOP/RESET button on the front integrated control panel. If running via terminal 2-wire/3-wire control, ensure the running command is de-asserted first.
- Logic Input Reset (LI): Configure an assigned logic terminal (LI1 to LI6) configured for [Fault reset] (rSt) in the [FAULT MANAGEMENT] (FLt-) menu, then switch the input from 0 to 1.
- SoMove PC Software: Connect via the front RJ45 Modbus serial port using a USB-to-RS485 PC adapter cable (TCSMCNAM3M002P) and select “Fault Reset” in the monitoring menu.
- Modbus RTU Control Word: Write Bit 7 (Fault Reset) from `0` to `1` in Command Word (`CMD`) via RS-485 serial communication.
- Dual Power Cycle (Solar PV & AC Backup): Open both the photovoltaic DC array isolator and any AC grid/generator backup switch. Wait at least 15 minutes for the DC bus capacitors to discharge until the 4-digit display completely clears before switching power back on.
⚠️ High-Voltage Photovoltaic & Electrical Safety Warning:
Photovoltaic (PV) arrays generate lethal DC voltages whenever exposed to light. Always open both the DC PV isolator and AC grid disconnect switches, and verify using a calibrated DC multimeter that intermediate bus voltage measures strictly below 42VDC across terminals [PA/+] and [PC/-] before inspecting terminal connections, wiring, or touching terminals U, V, and W on the Schneider ATV312 Solar drive.