WEG ADL300 Elevator Drive Fault Codes & Diagnostic Guide
Complete fault code reference directory, trip alarm causes, and step-by-step troubleshooting procedures for the WEG (Gefran) ADL300 specialized elevator vector inverter series. Search or filter through the complete fault code directory below.
Power Range
1.1 – 75 kW (1.5 – 100 HP)
Supply Voltage
230V (1-Ph/3-Ph) / 400–480V (3-Ph)
Control Modes
Field Oriented Vector (FOC / Closed Loop)
Operator Interface
Integrated 7-Segment / KB-ADL Keypad
Complete WEG ADL300 Drive Fault Code Directory
Use the search box in the table below to quickly find your code (e.g., type Overvoltage, SpdFbkLoss, or Desat IGBT).
| Alarm Code, Display [Integrated Keypad] | Cause and Solution / Remedy |
|---|---|
| 0 No alarm | Cause: No alarm present. Remedy: No action required. |
| 1 [OV] Overvoltage Display: O U | Cause: DC link overvoltage alarm due to energy recovered from the motor. The voltage arriving at the drive power section is too high compared to the maximum threshold relating to the PAR 560 Mains voltage parameter setting. Remedy:
|
| 2 [UV] Undervoltage Display: U u | Cause: DC link undervoltage alarm. The voltage arriving at the drive power section is too low compared to the minimum threshold relating to the 560 Mains voltage parameter setting due to:
Remedy: Check the connections and mains voltage. |
| 3 [GNDF] Ground fault Display: G n d F | Cause: Ground short circuit alarm. Remedy:
|
| 4 [OC] Overcurrent Display: o C | Cause: Instantaneous overcurrent protection intervention alarm. This may be due to the incorrect setting of current regulator parameters or a short circuit between phases or ground fault on the drive output. Remedy:
|
| 5 [DES] Desaturation Display: d E S | Cause: Instantaneous overcurrent in the IGBT bridge alarm. Remedy:
|
| 6 [MUV] MultiUndervolt Display: n U O | Cause: The number of attempted automatic restarts after the Undervoltage alarm has exceeded the set PAR 4650 UVRep attempts value in the PAR 4652 UVRep delay time. Remedy: Too many Undervoltage alarms. Adopt the proposed solutions for the Undervoltage alarm. |
| 7 [MOC] MultiOvercurr Display: n O C | Cause: Two attempted automatic restarts after the Overcurrent alarm within 30 seconds. If more than 30 seconds pass after the Overcurrent alarm was generated, the attempt counter is reset. Remedy: Too many Overcurrent alarms. Adopt the proposed solutions for the Overcurrent alarm. |
| 8 [MDES] MultiDesat Display: n d E S | Cause: Two attempted automatic restarts after the Desaturation alarm within 30 seconds. If more than 30 seconds pass after the Desaturation alarm was generated, the attempt counter is reset. Remedy: Too many Desaturation alarms. Adopt the proposed solutions for the Desaturation alarm. |
| 9 [HOT] Heatsink OT Display: H o t | Cause: Heatsink temperature too high alarm. Remedy:
|
| 10 [HSOT] HeatsinkS OTUT Display: H S O t | Cause: IGBT modules temperature too high or too low alarm. Remedy:
|
| 11 [IOT] Intakeair OT Display: I O t | Cause: Input air temperature too high alarm. Remedy:
|
| 12 [MOT] Motor OT Display: n O t | Cause: Motor overtemperature alarm. Possible causes:
Remedy:
|
| 13 [DOL] Drive overload Display: d o L | Cause: Drive overload alarm.
Remedy:
|
| 14 [MOL] Motor overload Display: n O L | Cause: Motor overload alarm. The current absorbed during operation is greater than that specified on the motor data plate. Remedy:
|
| 15 [BOL] Bres overload Display: b o L | Cause: Braking resistor overload alarm. The current absorbed by the resistor is greater than the rated current. Remedy:
|
| 16 [PHL] Phase loss Display: P H L | Cause: Power phase loss alarm. Remedy: Check the mains voltage and whether any protections upstream of the drive have been tripped. |
| 17 [OPTB] Opt Bus fault Display: o P t b | Cause: Error in the configuration stage or communication error.
Remedy: For configuration errors, check the configuration of the Bus communication, Bus type, Baudrate, address, and parameter settings. For communication errors verify wiring, resistance of terminations, interference immunity, and timeout settings. For further details reference should be made to the datasheet of the bus being used. |
| 18 [OPT1] Opt 1 IO fault Display: o P t 1 | Cause: Error in the communication between Regulation and I/O expansion card in slot 1 (Advanced version only). Remedy: Check that it has been inserted correctly, see Appendix section A.1. |
| 19 Opt 2 IO fault Display: o P t 2 | Cause: Error in the communication between Regulation and encoder expansion card in slot 2 (Advanced version only). Remedy: Check that it has been inserted correctly, see Appendix section A.1. |
| 20 [OPTE] Opt Enc fault Display: o P t E | Cause: Error in the communication between Regulation and Encoder feedback card (Advanced version only). Remedy: Check that it has been inserted correctly, see Appendix section A.1. |
| 21 [EF] External fault Display: E F | Cause: External alarm present. A digital input has been programmed as an external alarm, but the +24V voltage is not available on the terminal. Remedy: Check that the terminal screws are tight. |
| 22 [SFL] Speed fbk loss Display: S F L | Cause: Speed feedback loss alarm. The encoder is not connected, not connected properly or not powered: verify encoder operation by selecting the PAR 260 Motor speed parameter in the MONITOR menu. Remedy: See parameter 2172 SpdFbkLoss code for information about the cause of the alarm and chapter 10.2 Speed fbk loss [22] alarm. |
| 23 [OS] Overspeed Display: o S | Cause: Motor overspeed alarm. The motor speed exceeds the limits set in the PAR 4540 parameter. Remedy:
|
| 24 [SRL] Speed ref loss Display: S r L | Cause: Speed reference loss alarm; occurs if the difference between the speed regulator reference and the actual motor speed is more than 100 rpm. This condition occurs because the drive is in the current limit condition. It is only available in the Flux Vect OL and Flux Vect CL mode (see PAR 4550). Remedy: Check that the load is not excessive. |
| 26 [PRR] Power down Display: P d | Cause: The drive was enabled with no supply voltage at the power section. Remedy: Check drive power supply. |
| 27 [PHLO] Phaseloss out Display: P H L o | Cause: Output phase loss. Remedy: Check Drive/motor connection. |
| 28 [OVSF] OV safety Display: b U S F | Cause: Safety status alarm caused by Overvoltage situations. Remedy: The firmware attempts to reset the card automatically. If the condition is removed (the alarm cleared message is displayed), the alarm can be reset and the drive restarted by deactivating and reactivating Enable and Start. |
| 29 [SF] Safety failure Display: S F | Cause: The state of the "safety function" is communicated to the regulation card via 2 digital inputs: SAFETY_ON (pin P1.8) and SAFETY_EN (pin P1.9). Remedy: Switch the drive off and then back on. If the error persists, contact the technical service centre. |
| 30 [MOTL] Mot phase loss Display: n O t L | Cause: Output phase loss. Remedy: Check Drive/motor connection. |
| 31 [ROPC] Rope change Display: P o P C | Cause: This may occur under two conditions:
Remedy: Replace the ropes. By switching the drive off and back on, you can run a single travel to bring the car to a better position for the procedure. After you have changed the ropes, reset the direction change counter to eliminate the lock condition. |
| 32 [PERR] Phasing error Display: P E r r | Cause: Motor phasing error at startup. Remedy: Check encoder configuration parameters, parameter 2028 Take status, and encoder electrical connections. |
| 33 ... 40 [PLC1...8] Plc1 fault ... Plc8 fault Display: P L C 1 ... P L C 8 | Cause: Enabled application developed in the IEC 61131-3 environment has found the conditions for generating this specific alarm to be true. The meaning of the alarm depends on the type of application. The XXXXH-X sub-code indicates the reason for the error. Remedy: Refer to the documentation concerning the enabled application. Make a note of the XXXXH-X code to discuss it with the service centre. With regards to the standard application EFC, refer to the Functional Parameter Manual section LIFT ALARMS. For the applications DCP3/DCP4, EPC, and CiA 417, refer to the application manual section ALARMS. |
| 41 [WDT] Watchdog Display: y d t | Cause: May occur during functioning when the watchdog microcontroller protection is enabled; the alarm is included in the list of alarms and alarm log. Following this alarm:
The XXXXH-X sub-code indicates the reason for the error. Remedy: If the alarm was the consequence of a change in the drive configuration (parameter setting, option installation, PLC application download), remove it. Switch the drive off and then on again. Make a note of the XXXXH-X code to discuss it with the service centre. |
| 42 [TRAP] Trap error Display: E r A P | Cause: This condition can occur during operation when the trap micro protection is enabled. The alarm is included in the list of alarms and alarm log. Following this alarm:
The XXXXH-X code (SubHandler-Class) indicates the reason for the error. Remedy: If the alarm was a consequence of a variation to the drive configuration (parameter setting, installation of an option, downloading of a PLC application), remove it. Switch the drive off and then switch it on again. Make a note of the XXXXH-X (SubHandler-Class) code to discuss it with the service centre. |
| 43 [SYS] System error Display: 5 4 5 | Cause: This condition can occur during operation when the operating system protection is enabled. The alarm is included in the list of alarms and alarm log. Following this alarm:
The XXXXH-X code (Error-Pid) indicates the reason for the error. Remedy: If the alarm was a consequence of a variation to the drive configuration (parameter setting, installation of an option, downloading of a PLC application), remove it. Switch the drive off and then switch it on again. Make a note of the XXXXH-X (Error-Pid) code to discuss it with the service centre. |
| 44 [USR] User error Display: U S r | Cause: This condition can occur during operation when the software protection is enabled. The alarm is included in the list of alarms and alarm log. Following this alarm:
The XXXXH-X (Error-Pid) code indicates the reason for the error. Remedy: If the alarm was a consequence of a variation to the drive configuration (parameter setting, installation of an option, downloading of a PLC application), remove it. Switch the drive off and then switch it on again. Make a note of the XXXXH-X (Error-Pid) code to discuss it with the service centre. |
| 45 [PE] Param error Display: P E | |
| 1 [LDEF] Load default param Display: L d E F | Cause: May occur during loading of the parameter database saved in flash. This normally appears at initial power-on when a new firmware version is downloaded, when the regulation is installed on a new size, or when the region is changed. If this message is displayed when the drive is already operating, this means that a problem has occurred in the parameter database saved in Flash. If this message is displayed, the drive automatically performs the Load default command. Diagnostic Sub-codes:
Remedy: Set the parameters to the value required and perform Save parameter. |
| 2, 3, 4 [OPT1, OPT2, OPT3] Option detect slot 1, 2, 3 Display: o P t 1 / o P t 2 / o P t 3 | Cause: When the drive is turned on, it recognises the presence of an optional card. One of the sub-code messages is shown on the display for a few seconds. Diagnostic Sub-codes:
Remedy: This is a temporary informational display. No troubleshooting action is required unless the wrong module type is identified. |
| 5 [SLFT] Autotune (motor) Display: S L F t | Cause: May occur during the self-tuning procedure. Diagnostic Sub-codes:
Remedy: If the message appears with a value other than 0, follow the instructions supplied for each particular case and repeat self-tuning. This should be performed using the wizard function available from the keypad (STARTUP WIZARD) and the Tool software on the PC. Pay attention to all motor plate data parameters, especially:
If the problem persists, confirm the values of the motor plate parameters and execute the Take parameters command, but do not run self-tuning. |
| 5 [SLFT] Autotune (phasing) - Only Synchronous Display: S L F t | Cause: May occur during the self-tuning phasing procedure on synchronous motors. Diagnostic Sub-codes:
Remedy: If the message has a value other than 0, follow the instructions provided for each case and repeat automatic phasing:
|
| 6 [PC] Power config Display: P C | Cause: May occur during recognition of power cards. If this message is displayed, it is not possible to drive the motor. Diagnostic Sub-codes:
Remedy: Download the correct configuration on the power card. |
| 7 [FAIL] Save par failed Display: F A I L | Cause: Occurs during transfer of the parameters from the drive to the memory of the keypad. Diagnostic Sub-codes:
Remedy: Verify keypad physical connection and check for noise on the communication bus. |
| 8 / 9 [FAIL] Load par failed / Load par incomplete Display: F A I L | Cause: Occurs during transfer of the parameters from the memory of the keypad to the drive. Diagnostic Sub-codes:
Remedy: Recover a set of parameters from a compatible drive (matching model and size). |
| 10 [OPTC] Options config error Display: o P t C | Cause: May occur at drive start-up, during recognition of the optional cards installed. Diagnostic Sub-codes:
Remedy: Remove the optional cards from the incorrect slots and insert them in the correct slots. |
| 11 [LDPL] Load def plc Display: L d P L | Cause: May occur during loading of the parameter database saved in the Flash of the Mdplc application. Normally appears at initial power-on after downloading a new application. If this message is displayed when the drive is already operating, this means that a problem has occurred in the parameter database saved in Flash. The drive restores the default database.
Remedy: Set the parameters to the value required and perform Save parameter. |
| 12 [PLCE] Plc cfg error Display: P L C E | Cause: May occur during loading of the Mdplc application. The Mdplc application present on the drive is not run.
Remedy: Remove the Mdplc application or download a correct Mdplc application. |
| 12 [PLCE] Plc cfg error (Continuation) Display: P L C E | Cause: Fault related to Mdplc application loading (continued).
Remedy: Remove the Mdplc application or download a correct, valid Mdplc application file. |
| 13, 14, 15, 16 [PLC1...4] Plc 1 ... Plc 4 Display: P L C 1 / P L C 2 / P L C 3 / P L C 4 | Cause: Reserved messages dedicated to the PLC application. Remedy: See the application manual for specific PLC instructions. |
| 17 [OPTB] Opt bus fault Display: o P t b | Cause: This may occur during fieldbus card setup on drive power-on. It indicates a configuration or communication error.
Remedy:
Refer to the user guide for the specific bus in use. |
| 18 [KEYF] Wrong key Display: H E 4 F | Cause: This may occur when powering the drive if the incorrect enable key is inserted for a given firmware function.
Remedy: Contact WEG to obtain the correct key to enable the desired firmware function. |
| 19 [KEYE] Key expiring Display: H E 4 E | Cause: This may occur at drive power-on if an incorrect enabling key was inserted for a given firmware function. At this stage, the firmware function can still be used freely, but the trial time limit is about to expire.
Remedy: Contact WEG to obtain the correct permanent key to enable the desired firmware function. |
| 20 [FAIL] SD card error Display: F A I L | Cause: This condition may occur when sending data from the drive to the SD card or from the SD card to the drive. It is typically caused by a memory card that is incompatible or not present.
Remedy: Check the physical connection and compatibility of the memory card being used. |
| 21 [PE] Parameter error Display: P E | Cause: An error occurs during the activation of the parameter database saved in flash; one or more parameters have values out of range.
Remedy: Set the parameter causing the error to the correct value and execute Save parameters, then switch the drive off and back on again. Make a note of the specific sub-code to discuss with the service center. |
| 22 [ENCE] Encoder error Display: E n C E | Cause: This condition may occur when the drive is powered during encoder setup each time parameter 552 Regulation mode is set.
Remedy:
|
| 23 [OCFG] Options cfg changed Display: o C F G | Cause: This may occur when powering the drive if an expansion card has been removed or replaced, or the incorrect enable key is inserted for a given firmware function.
Remedy: Check the physical hardware configuration, then press ESC. Save the parameters (Save parameters, menu 04.01 par 550) to save the new hardware configuration. |
| 24 [FAIL] Fw update failed Display: F A I L | Cause: During a firmware update, the system detected that the file is in the wrong format or is corrupt. Remedy: Try the update again with a correct, uncorrupted firmware file. |
How to Clear & Reset WEG ADL300 Drive Faults
- Keypad Reset: Press the dedicated Reset key on the optional KB-ADL alphanumeric programming keypad, or navigate to parameter PAR: 560 (Alarm reset) via the integrated 7-segment display.
- Digital Input Reset (DI): If allocated in the digital input programming menu, momentarily energize the terminal assigned to the Alarm Reset command via the elevator controller safety circuit.
- GF-eXpress PC Tool: Connect your PC to the serial communication port, launch the GF-eXpress configuration software, and execute “Drive Reset” from the diagnostic toolbar.
- Lift Controller Protocol: Transmit the reset command bit over CANopen Lift (CiA 417), DCP3, DCP4, or Modbus serial communication from the master elevator control board.
- Power Cycle: Disconnect the incoming 3-phase or 1-phase AC mains power supply, wait until the internal DC bus indicator LEDs extinguish completely (approx. 5 minutes for discharge), and reapply power.
⚠️ High-Voltage Electrical Safety Warning:
Ensure that the elevator car is safely mechanically secured with counterweights balanced or mechanical safety gear locked. Always verify with a calibrated digital multimeter that the DC bus intermediate voltage measures strictly below 50VDC across terminals [+DC] and [-DC] before opening covers or inspecting motor leads (U, V, W).