The A2017 alarm alerts personnel that a drive stop command was pressed on the integrated control panel while the local control mode lock was actively engaged. The drive ignores the keypad stop button to preserve dedicated remote automation supervisory control.
To prevent unauthorized personnel from interrupting critical production machinery, parameter 1606 LOCAL LOCK can disable keypad pushbuttons. When an operator presses the keypad STOP/OFF key while this safety lock is active, the drive micro-controller rejects the local override command. The inverter continues modulating gate pulses across the IGBT bridge according to remote start/stop commands arriving through control terminal strip X1, maintaining normal motor torque and DC bus voltage stability without interruption.
What Causes A2017 in ABB ACS150?
- An operator pressed the integrated STOP key on the keypad while parameter
1606 LOCAL LOCKwas enabled. - The drive is operating under remote PLC automation control with local override locked to prevent manual process disruption.
- A stuck or damaged keypad membrane switch continuously actuating the physical OFF button contacts.
- Parameter
1606 LOCAL LOCKassigned to a digital input terminal (e.g.,DI1throughDI5) that is currently energized. - Misunderstanding of operational control modes between local keypad control (LOC) and external terminal control (REM).
Step-by-Step Troubleshooting and Solutions
- Check parameter
1606 LOCAL LOCK; change the setting to0 = NOT SELto allow the keypad STOP button to halt drive modulation. - If parameter
1606 LOCAL LOCKis assigned to a digital input terminal (e.g.,DI3), check control terminal voltage with a multimeter to verify whether the input is held high by external 24V DC logic. - To stop the drive safely while local lock is active, use the designated external remote stop circuit wired to terminal strip
X1. - Inspect the keypad faceplate for mechanical damage, foreign substance contamination, or sticky membranes holding the stop key depressed.
- Verify whether plant operating procedures require local lockout before modifying parameter configurations.
Preventative Maintenance to Avoid A2017 Faults
Clearly label control cabinets to indicate whether drive local controls are locked out, train operators on remote terminal stop stations, and inspect keypad membrane cleanliness during regular preventive maintenance cycles.
Frequently Asked Questions (FAQs)
What is the meaning of A2017 fault in ABB ACS150 drive?
Alarm A2017 indicates that someone pressed the keypad stop button while local control was locked by parameter 1606.
What are the primary causes of A2017 fault?
The primary causes are active local control lockout settings in parameter 1606, remote PLC priority enforcement, or a stuck keypad button.
How do I troubleshoot and correct A2017 fault?
Disable the local lock by reconfiguring parameter 1606 LOCAL LOCK, or use the designated remote digital stop circuit on terminal block X1.