The A2011 alarm indicates that the mechanical load on the motor has dropped below the minimum permissible torque curve configured in the ABB ACS355 drive. This warning alerts personnel that the motor is running underloaded without shutting down inverter switching immediately.
When the load drops below normal running requirements, the magnetic flux and active current delivered through the inverter power semiconductors fall rapidly. In applications such as pumps running dry, broken drive belts, or snapped mechanical couplings, prolonged operation under this condition risks mechanical cavitation or secondary equipment failure while intermediate DC link voltage remains nominally balanced.
What Causes A2011 in ABB ACS355?
- Broken transmission belt, sheared shaft pin, or disconnected mechanical drive coupling.
- Centrifugal pump running dry or losing prime during continuous pumping service.
- Oversized motor installed relative to the actual mechanical power demand.
- Underload protection curve parameters set too aggressively in Group
30 FAULT FUNCTIONS. - Sudden process disruption such as an empty feeder, closed intake damper, or disengaged clutch.
Step-by-Step Troubleshooting and Solutions
- Inspect mechanical linkages, belts, gearboxes, and shaft couplers between the motor and machine for mechanical disconnection.
- Check pump lines for fluid flow, cavitation, or air entrapment in fluid delivery setups.
- Verify underload function configuration in parameter
3013 UNDERLOAD FUNCand time limit parameter3014 UNDERLOAD TIME. - Adjust parameter
3015 UNDERLOAD CURVEto fit the true minimal operational torque envelope of the driven load. - Compare motor nameplate rating in
9909 MOTOR NOM POWERwith actual running kilowatt values displayed on the control panel.
Preventative Maintenance to Avoid A2011 Faults
Regularly inspect belt tensions, maintain mechanical coupling alignment, monitor process flow rates, and verify that underload curve tolerances reflect mechanical component wear over continuous run cycles.
Frequently Asked Questions (FAQs)
What is the meaning of A2011 fault in ABB ACS355 drive?
The A2011 alarm indicates that the active motor load has fallen below the drive’s programmed underload curve threshold.
What are the primary causes of A2011 fault?
Key triggers include sheared mechanical drive couplings, broken belts, dry running pump casings, or overly sensitive underload threshold settings.
How do I troubleshoot and correct A2011 fault?
Inspect all mechanical driveline linkages, confirm fluid presence in pump systems, and adjust parameter 3015 to match expected operating curves.