The F0018 fault indicates an internal hardware failure where the drive internal thermistor sensor used for heatsink temperature measurement is open or short-circuited. The drive executes an immediate emergency shutdown to protect the power semiconductors from unmonitored thermal runaway.
The ACS355 utilizes an embedded negative temperature coefficient (NTC) or positive temperature coefficient (PTC) thermistor mounted directly onto the power module substrate beneath the IGBT bridge. The analog-to-digital converter continuously samples the voltage divider circuit formed by this thermistor. If the circuit detects open-loop resistance (infinite ohms) or a direct short circuit (zero ohms), the CPU detects a hardware transducer failure. Inverter modulation is locked out instantly to prevent firing the IGBTs without verified thermal monitoring.
What Causes F0018 in ABB ACS355?
- Internal temperature-sensing thermistor fractured or open-circuited due to thermal stress or mechanical shock.
- Short circuit across the internal heatsink thermistor traces or ribbon connectors on the main power board.
- Analog front-end measuring circuit failure or blown pull-up resistor on the drive control board.
- Severe moisture condensation or conductive particulate contamination bridging sensor tracks on the power PCB.
- Internal hardware failure following severe output short circuits or previous high-energy thermal events.
Step-by-Step Troubleshooting and Solutions
- Isolate main incoming AC power (
U1, V1, W1), wait5 minutesfor the DC link capacitors to deplete, and inspect the drive for physical burning or chemical odor. - Check parameter
0109 DRIVE TEMPon the control panel display; an impossible reading such as-20 °C,0 °C, or150 °Cconfirms an open or shorted sensor circuit. - Inspect the drive enclosure for moisture, water ingress, or conductive dust accumulation; dry and clean the internal chassis with dry, oil-free compressed air if safe to do so.
- Attempt a complete line power reset after letting the drive cool down to ambient temperature; observe whether the fault trips immediately upon power-up before any run command.
- Because the internal heatsink thermistor is an integral component of the sealed power stage, an unresolved
F0018requires repair by an authorized ABB workshop or complete drive replacement.
Preventative Maintenance to Avoid F0018 Faults
Maintain control cabinet climate control within -10 °C to +40 °C, deploy anti-condensation heaters in high-humidity operating environments, and clean drive ventilation passages annually to prevent extreme thermal cycling that stresses internal sensor bonding.
Frequently Asked Questions (FAQs)
What is the meaning of F0018 fault in ABB ACS355 drive?
It is a critical hardware protection fault indicating that the internal heatsink temperature measurement thermistor is broken, open, or short-circuited.
What are the primary causes of F0018 fault?
Leading causes include internal thermistor element breakage, shorted power card sensing traces, severe moisture contamination, or analog input circuitry failure.
How do I troubleshoot and correct F0018 fault?
Check parameter 0109 for abnormal readings, cycle line power after cooldown, and replace the drive or control board as this is a permanent hardware defect.