A591 alarm in ABB ACS380 drive

Home/ABB/ABB ACS380 drive/A591 alarm in ABB ACS380 drive

Warning A591 in the ABB ACS380 drive signifies that the drive hardware self-initialization or power-up configuration sequence is currently active. The drive processor prevents motor start commands until all peripheral hardware registers, FPGA logic, and parameter pointers finish loading.

During cold boot, control reboot, or following a major firmware and hardware parameter restoration, the central microcontroller interrogates all onboard chips, power stage memory, analog-to-digital converters, and fieldbus option cards. Warning code A591 informs operators that the initialization routines are executing normally. Auxiliary code 0000 indicates standard drive hardware setup is running, while auxiliary code 0001 denotes that factory hardware settings are being structured for the first time. If the warning persists indefinitely, the boot sequence has encountered a stalled hardware handshake or non-volatile EEPROM memory read timeout.

What Causes A591 in ABB ACS380?

  1. Standard power-on boot routine executing its baseline diagnostic hardware scan upon application of AC input power.
  2. Initial first-time commissioning or complete factory default reset restructuring non-volatile parameter memory.
  3. Auxiliary code 0000 active during routine drive hardware self-test and internal bus synchronization.
  4. Auxiliary code 0001 active during initial hardware profile configuration or replacement module identification.
  5. Corrupted flash memory or interrupted firmware update locking the drive bootloader in an infinite initialization loop.

Step-by-Step Troubleshooting and Solutions

  1. Allow sufficient time—typically 30 to 90 seconds—for auxiliary code 0000 or 0001 to complete without cycling power.
  2. Examine auxiliary diagnostic codes under parameter 04.11 Fault subcode or 04.12 Warning subcode to identify the specific pending process.
  3. Verify main control input voltage stability across control terminals +24V and DGND to ensure low voltage does not stall the processor.
  4. If code A591 persists beyond three minutes, perform a controlled power cycle by de-energizing line supply until the keypad screen turns off completely.
  5. If the drive locks on initialization permanently, use ABB Drive Composer software to reflash system firmware or reinstall the baseline macro.

Preventative Maintenance to Avoid A591 Faults

Avoid cutting input mains power abruptly during parameter downloads, macro configuration, or firmware flashing operations. Install an uninterruptible 24V DC auxiliary power supply on critical ACS380 panels to ensure microcontrollers finish clean non-volatile memory writes during line dropouts.

Frequently Asked Questions (FAQs)

What is the meaning of A591 fault in ABB ACS380 drive?

The A591 warning indicates that the drive hardware is performing normal startup initialization or first-time parameter memory setup.

What are the primary causes of A591 fault?

Primary causes are normal power-up hardware scanning, factory reset configuration loading, or stalled bootloader execution caused by voltage dips.

How do I troubleshoot and correct A591 fault?

Allow the initialization cycle to finish naturally, check the auxiliary subcode, confirm 24V supply stability, and power-cycle if the unit freezes.