A2013 AUTORESET alarm in ABB ACS550 drive

Home/ABB/ABB ACS550 drive/A2013 AUTORESET alarm in ABB ACS550 drive

The A2013 AUTORESET alarm in the ABB ACS550 drive indicates that an automatic fault reset sequence has been initiated by the drive control supervisor. The drive displays this operational warning to notify operators that an active trip condition is currently undergoing an automatic clearing and restart attempt.

The ACS550 features an autonomous fault-clearing supervisor governed by parameter group 31 AUTOMATIC RESET. When an enabled transient condition occurs—such as instantaneous overcurrent, intermediate DC bus overvoltage, or analog input loss—the processor suppresses a permanent lockout, pauses PWM output, and initiates a countdown timer set in parameter 3103 DELAY TIME. During this window, the A2013 alarm remains active on the control panel. If the underlying fault clears within the programmed retry trials, the drive re-engages motor modulation without manual human intervention.

What Causes A2013 in ABB ACS550?

  1. A transient overvoltage condition on the DC bus triggering an automatic reset cycle configured via parameter 3105.
  2. A brief output overcurrent surge activating the automatic reset logic governed by parameter 3104.
  3. Temporary loss of analog reference signal on terminals AI1 or AI2 triggering auto-reset under parameter 3106.
  4. Parameter 3101 NR OF TRIALS or 3102 TRIAL TIME configured to repeatedly attempt clearing an uncorrected underlying hardware fault.
  5. Severe electrical noise or utility line fluctuations intermittently tripping and re-triggering automatic restart routines.

Step-by-Step Troubleshooting and Solutions

  1. Review parameters in group 31 AUTOMATIC RESET, specifically verifying parameter 3101 NR OF TRIALS, 3102 TRIAL TIME, and 3103 DELAY TIME.
  2. Inspect the fault logger in parameter group 04 FAULT HISTORY to identify the primary root fault (e.g., F0001, F0002, or F0007) that triggered the auto-reset cycle.
  3. Check input power line stability across terminals U1, V1, W1 to verify whether utility voltage sags or surges are causing repeated auto-resets.
  4. Temporarily disable automatic reset by setting parameter 3101 to 0 to allow the primary fault to latch on the display for direct diagnostics.
  5. Inspect analog command wiring across terminals AI1 and AI2 for intermittent loose connections or signal drops.

Preventative Maintenance to Avoid A2013 Faults

Review fault history logs during routine maintenance rounds to spot recurring auto-reset patterns, ensure line reactors are installed on noisy supply grids, and verify that mechanical load fluctuations stay within normal operating margins.

Frequently Asked Questions (FAQs)

What is the meaning of A2013 alarm in ABB ACS550 drive?

The A2013 AUTORESET alarm signifies that the drive has detected a fault and is executing an automatic diagnostic countdown to clear the trip and restart.

What are the primary causes of A2013 alarm?

This alarm is triggered when transient conditions like momentary overcurrent, DC overvoltage, or input signal loss engage the automated reset routine in group 31.

How do I troubleshoot and correct A2013 alarm?

Examine the fault history in parameter group 04 to locate the root trip code, review group 31 parameters, and address the external electrical or load disturbance.