5682 fault in ABB ACS560 drive

Home/ABB/ABB ACS560 drive/5682 fault in ABB ACS560 drive

The 5682 fault indicates that the physical connection between the drive control unit and the power unit is completely lost in the ABB ACS560. The drive shuts down immediately to ensure that unmonitored power stage operations cannot occur.

Total loss of communication to the power unit means the control unit has lost all feedback regarding intermediate DC link voltage, heatsink temperature, and phase current levels. In this unlinked state, the control processor cannot safely control IGBT gate firing pulses. The drive immediately locks out all modulation commands, holding the power stage in an unmodulated safe state and preventing output current delivery through motor terminals U2, V2, W2.

What Causes 5682 in ABB ACS560?

  1. Complete disconnection, uncoupling, or severe damage to the internal ribbon harness linking the control unit to the power unit.
  2. Total failure of the auxiliary power supply section providing logic power to the power unit board.
  3. Severe mechanical shock or persistent industrial vibration dislodging internal modular card-edge connections.
  4. Hardware component breakdown or catastrophic microprocessor failure on the power unit interface board.
  5. Corrupted internal bus driver circuit or broken PCB traces on the drive control unit.

Step-by-Step Troubleshooting and Solutions

  1. Disconnect incoming three-phase AC mains power, allow the DC link to discharge below 50V DC, and open the drive enclosure.
  2. Inspect the physical ribbon cable connecting the control unit to the power unit; ensure it is fully inserted and locked into place.
  3. Examine the internal connectors for bent pins, physical cracking, or contamination that could break electrical contact.
  4. Check internal DC power rails on the power unit using an insulated multimeter to verify that logic supply voltages are present.
  5. Perform an insulation resistance test at 500V DC across motor leads U2, V2, W2; if connections are intact but fault remains, replace the unit.

Preventative Maintenance to Avoid 5682 Faults

Ensure drive cabinets are isolated from severe machinery vibration using anti-vibration mountings, check internal connector retention clips during periodic overhauls, and maintain proper panel climate control to avoid contact oxidation.

Frequently Asked Questions (FAQs)

What is the meaning of 5682 fault in ABB ACS560 drive?

The 5682 fault indicates that the physical communication link between the drive control unit and power unit has been completely lost, disabling the drive.

What are the primary causes of 5682 fault?

Primary causes include disconnected internal communication cables, failed auxiliary power supplies on the power unit, severe mechanical vibration, and broken board traces.

How do I troubleshoot and correct 5682 fault?

Isolate power, inspect and re-seat the internal control-to-power unit connection cable, verify auxiliary logic voltages, and replace damaged hardware if needed.