The 6885 fault indicates an internal text file overflow error where the drive operating system memory buffers have been exhausted by excessive string data or corrupted text files. The ABB ACS560 trips to prevent corruption of adjacent microprocessor execution memory.
The ACS560 control architecture manages internal non-volatile memory partitions dedicated to parameter text descriptions, fault logger string records, multilingual interface files, and user custom macros. When an internal software routine compiles diagnostics or parses language packages, memory pointers allocate temporary text buffers in volatile RAM. If corrupted language files, excessive custom parameter tagging, or software memory leaks drive string allocations beyond pre-allocated heap limits, the CPU triggers 6885. Motor modulation across terminals U2, V2, W2 is stopped immediately to prevent unpredictable control execution while internal memory allocation tables remain unstable.
What Causes 6885 in ABB ACS560?
- Corrupted language package or localized text translation files loaded into drive flash memory.
- Diagnostic event logger buffer overflow caused by continuous, high-frequency alarm generation.
- Interrupted firmware flashing or incomplete language pack download executed via ABB Drive Composer.
- Transient volatile RAM pointer corruption caused by sudden control board auxiliary power drops.
- Internal flash memory hardware sector degradation on the drive main control board.
Step-by-Step Troubleshooting and Solutions
- Reset the Drive Trip: Attempt a direct fault reset using the keypad
Resetkey, or trigger a reboot via parameter96.08 Control board boot. - Perform Cold Power Cycle: De-energize the incoming line supply across terminals
U1, V1, W1, allow the intermediate DC bus to drop below5V DC, wait two minutes, and re-energize. - Clear Fault Event Logger: Access the event log via the assistant control panel and clear historical event records to relieve volatile memory storage.
- Reflash Firmware and Language Files: Connect a PC running ABB Drive Composer to the control panel port and perform a complete firmware update, ensuring the standard language package is reinstalled cleanly.
- Replace Control Unit: If the
6885fault recurs immediately after a clean firmware flash and factory reset, replace the drive control board.
Preventative Maintenance to Avoid 6885 Faults
Maintain clean, stable auxiliary 24V DC power feeds to avoid abrupt power cuts while the drive is committing event logs to flash memory. Keep drive firmware updated to the latest certified ABB revision to benefit from memory management optimizations.
Frequently Asked Questions (FAQs)
What is the meaning of 6885 fault in ABB ACS560 drive?
The 6885 fault indicates that internal text buffer memory has overflowed due to corrupted language files, excessive event logging, or software memory allocation errors.
What are the primary causes of 6885 fault?
Primary root causes include corrupted language translation packs, event log memory saturation, interrupted firmware downloads, or defective control board flash memory.
How do I troubleshoot and correct 6885 fault?
Reset the drive, execute a cold power cycle, clear historical event logs, reload the standard firmware package using Drive Composer, or replace the control board.