AFFE alarm in ABB ACS560 drive

Home/ABB/ABB ACS560 drive/AFFE alarm in ABB ACS560 drive

The AFFE warning indicates that the ABB ACS560 drive has entered dedicated Override Mode operation. This informational alarm signifies that standard interlocks and process controls are bypassed to enforce emergency operational speeds.

Override mode is specifically engineered for critical applications such as HVAC smoke evacuation, tunnel ventilation, and industrial exhaust extraction. When a designated override contact triggers, the ACS560 microprocessor transfers control authority to pre-configured emergency parameters in group 70 Override. During this state, the drive suppresses non-critical protective trips, bypasses building management system commands, and directs maximum pulse-width modulation to maintain air movement. Because this status indicates emergency operation where motor thermal thresholds may be disregarded, code AFFE alerts personnel that the inverter is under override control.

What Causes AFFE in ABB ACS560?

  1. Activation of a fire alarm or smoke evacuation contact wired to the digital input assigned in parameter 70.02 Override enable.
  2. A dedicated override command transmitted over Modbus RTU or an embedded fieldbus communication network.
  3. Incorrect wiring or a short circuit on the digital input terminal configured for override initiation.
  4. Commissioning technicians testing smoke purge sequences without subsequently resetting the test selector switch.
  5. A sticking emergency fire override contact on an external fire alarm control panel (FACP).

Step-by-Step Troubleshooting and Solutions

  1. Verify the operational state of the building fire management panel to determine if a true facility smoke evacuation emergency exists.
  2. Inspect parameter 70.02 Override enable to identify which digital input (e.g., DI1 through DI6) is mapped to activate override mode.
  3. Measure 24V DC signal levels at the mapped digital input terminal to verify whether the field contact is physically open or closed.
  4. Inspect field cables connected to the override terminal for short circuits, crushed insulation, or moisture ingress causing false triggering.
  5. Deactivate the override signal at the fire control interface; warning AFFE will clear automatically once normal control mode is restored.

Preventative Maintenance to Avoid AFFE Faults

Perform scheduled checks on fire alarm dry contacts and wiring conduits, verify override logic during routine annual safety audits, and maintain comprehensive records of emergency smoke purge interlocks across control systems.

Frequently Asked Questions (FAQs)

What is the meaning of AFFE fault in ABB ACS560 drive?

The AFFE code is an informational warning indicating that the drive has entered emergency override mode, bypassing standard operating limits.

What are the primary causes of AFFE fault?

This state is initiated by active fire alarm contacts, closed emergency purge switches, fieldbus override bits, or wiring faults on override digital inputs.

How do I troubleshoot and correct AFFE fault?

Inspect the fire alarm input assigned in parameter 70.02, confirm emergency control status, check terminal wiring, and reset the external trigger contact.