Danfoss MSD510 Servo Drive Fault Codes & Diagnostic Guide
Complete fault code reference directory, trip alarm causes, and diagnostic procedures for the Danfoss VLT® Multiaxis Servo Drive MSD 510 system (PSM 510, SDM 511, SDM 512). Search or filter through the complete diagnostic directory below.
Power Range
Up to 30 kW (1.5–30 A RMS/axis)
Supply Voltage
400–480V AC / 600V DC Link
Control Modes
Field Oriented Control (FOC Servo)
Communication
EtherCAT / POWERLINK / PROFINET IRT
Complete Danfoss MSD510 Drive Fault Code Directory
Use the search box in the table below to quickly find your servo alarm or warning (e.g., type AL01, AL03, Overcurrent, or Feedback).
| Fault Code and Meaning | Cause and Remedy |
|---|---|
| 0x1000 / 0x100 Generic application error | Cause: Generic application error. Remedy:
|
| 0x2310 / 0x101 Overcurrent on output | Cause: Overcurrent on output. Remedy:
|
| 0x2311 / 0x15F High current overload | Cause: High current overload error. Remedy:
|
| 0x2312 / 0x160 I²T current overload | Cause: I²T current overload error. The motor or drive thermal limit has been reached. Remedy:
|
| 0x2313 / 0x161 High power overload | Cause: High power overload error. Remedy:
|
| 0x2314 / 0x162 PT power overload | Cause: PT power overload error. Remedy:
|
| 0x2320 / 0x163 Short circuit | Cause: DC overcurrent short circuit error. Remedy:
|
| 0x2330 / 0x151 Earth leakage | Cause: Current leaking to earth. Remedy:
|
| 0x2391 / 0x125 AUX overcurrent | Cause: Current on the AUX line has reached the overcurrent limit. Remedy:
|
| 0x2393 / 0x127 AUX user limit current | Cause: Current on the AUX line has reached the user-defined limit for fault. Remedy:
|
| 0x2394 / 0x128 AUX user limit current warning | Cause: Current on the AUX line has reached the user-defined limit for warning. Remedy:
|
| 0x2395 / 0x129 AUX fuse failure | Cause: Fuse failure. Current or voltage is above the limit on the AUX line. Remedy:
|
| 0x2396 / 0x15C DC Overcurrent trip | Cause: DC overcurrent trip. Remedy:
|
| 0x2397 / 0x12B Output power trip | Cause: The peak output power of the device is exceeded. Remedy:
|
| 0x239B / 0x102 I²T overload motor | Cause: I²T overload motor error. Remedy:
|
| 0x3130 / 0x12F Mains phase loss | Cause: Mains phase loss detected. This occurs when a phase on mains is missing, or when the mains is imbalanced. Remedy:
|
| 0x3210 / 0x103 DC link overvoltage | Cause: DC-link voltage exceeds limit. Remedy:
|
| 0x3210 / 0x103 (SW) Overcurrent trip SW | Cause: DC-link voltage exceeds limit (Software trip). Remedy:
|
| 0x3220 / 0x104 DC link undervoltage | Cause: DC-link voltage below limit in "Operation enabled" state. Remedy:
|
| 0x3230 / 0x152 UDC charging error | Cause: The maximum time limit to charge the DC-link has been exceeded. Remedy:
|
| 0x3280 / 0x153 DC Link Voltage unbalanced | Cause: DC-link voltage unbalanced. Remedy:
|
| 0x3291 / 0x132 UAUX high voltage | Cause: UAUX above warning limit. Remedy:
|
| 0x3292 / 0x133 UAUX overvoltage | Cause: UAUX above overvoltage limit. Remedy:
|
| 0x3293 / 0x134 UAUX low voltage | Cause: UAUX below warning limit. Remedy:
|
| 0x3294 / 0x135 UAUX undervoltage | Cause: UAUX below undervoltage limit. Remedy:
|
| 0x3295 / 0x136 UDC high voltage | Cause: The DC-link voltage is higher than the high-voltage warning limit. Remedy:
|
| 0x3296 / 0x137 UDC low voltage | Cause: The DC-link voltage is lower than the low-voltage warning limit. Remedy:
|
| 0x3297 / 0x154 UAUX charging error | Cause: Load error when UAUX is charging. The maximum time limit to charge the AUX line has been exceeded. Remedy:
|
| 0x3298 / 0x165 UDC shutdown error | Cause: Error when UDC is in shutdown phase. Remedy:
|
| 0x3299 / 0x155 UAUX shutdown error | Cause: Error when UAUX is in shut down phase. Remedy:
|
| 0x329A / 0x156 UAUX undervoltage hardware | Cause: UAUX undervoltage detected by hardware circuit. Remedy:
|
| 0x329B / 0x168 Automated fault reset failure | Cause: Too many auto fault resets have been executed in the intended time interval. Remedy:
|
| 0x4210 / 0x157 Device overtemperature | Cause: Triggered when the maximum temperature of the main device component is exceeded. PSM: Thyristor rectifier module. DAM: Maximum temperature of both high side and low side IGBTs. Remedy:
|
| 0x4220 / 0x138 Too low temperature | Cause: The device is too cold to operate. Remedy:
|
| 0x4290 / 0x105 Overtemperature: Power module | Cause: Overtemperature on power module. Remedy:
|
| 0x4291 / 0x106 Overtemperature: Control card | Cause: Maximum temperature of control card exceeded. Remedy:
|
| 0x4292 / 0x107 Overtemperature: Power card | Cause: Maximum temperature of power card exceeded. Remedy:
|
| 0x4293 / 0x13C Inrush overtemperature: DC link | Cause: Inrush fault. Too many transitions into state "Operation enabled" in a short time period. Remedy:
|
| 0x4294 / 0x13D Inrush overtemperature AUX line | Cause: Inrush fault. Too many power-ups of the AUX voltage have occurred within a short time period. Remedy:
|
| 0x4310 / 0x108 Overtemperature: Motor | Cause: Overtemperature on motor. Remedy:
|
| 0x5112 / 0x109 UAUX undervoltage | Cause: Undervoltage on auxiliary voltage. Remedy:
|
| 0x5121 / 0x158 Charge switch failure voltage | Cause: Indicates a malfunction of the internal charge circuit. Remedy:
|
| 0x5530 / 0x10A EE Checksum Error (parameter missing) | Cause: Missing parameter in internal device configuration. Remedy:
|
| 0x6320 / 0x10B Parameter error | Cause: A parameter has an invalid value. Remedy:
|
| 0x6382 / 0x15D Configuration parameters version error | Cause: Configuration parameter set version mismatch: parameter set is not valid for this device. Remedy:
|
| 0x6383 / 0x164 Configuration parameters limits error | Cause: ≥1 parameter in the configuration parameter set is out of limits: the parameter set is not valid for this device. Remedy:
|
| 0x6384 / 0x166 Power EEprom configuration error | Cause: The power device Eeprom is corrupt or incompatible with this control board. Remedy:
|
| 0x7111 / 0x141 Brake chopper failure | Cause: The brake chopper is monitored during operation. A brake failure has been detected by the brake check function. Remedy:
|
| 0x7112 / 0x167 Brake chopper overcurrent | Cause: The brake chopper current exceeds the limit. Remedy:
|
| 0x7181 / 0x142 Brake resistor maximum power limit | Cause: The brake resistor maximum power limit is exceeded. Remedy:
|
| 0x7182 / 0x143 Brake resistor user power limit | Cause: The brake resistor power limit is exceeded. The power transmitted to the brake resistor is calculated as an average value over the last 300 s of run time. Calculation is based on DC-link voltage and brake resistor value set in parameter 2-16. Remedy:
|
| 0x7183 / 0x159 Brake mains voltage too high | Cause: The brake resistor mains voltage is too high. Remedy:
|
| 0x7320 / 0x10C Internal position sensor error | Cause: Absolute position sensor error. Remedy:
|
| 0x7380 / 0x10D External position sensor error | Cause: External encoder data could not be read. Remedy:
|
| 0x8611 / 0x10E Following error | Cause: A following error has occurred. Remedy:
|
| 0x8693 / 0x10F Homing error on entering homing mode | Cause: Could not enter homing mode (for example velocity not 0). Remedy:
|
| 0x8694 / 0x110 Homing error on start homing method | Cause: Could not start homing method (for example drive not in standstill). Remedy:
|
| 0x8695 (0x111) Homing error distance | Cause: Homing distance reached. Remedy:
|
| 0xFF01 (0x112) Mechanical brake failure | Cause: No brake or wire failure detected. Remedy:
|
| 0xFF02 (0x113) Short circuit in mechanical brake control | Cause: Short circuit in brake control. Remedy:
|
| 0xFF0A (0x114) External interface power failure | Cause: External interface power supply failure. Remedy:
|
| 0xFF10 (0x14F) Communication interrupted | Cause: The fieldbus communication has been interrupted while the device was enabled. Remedy:
|
| 0xFF21 (0x145) Fan feedback inconsistent | Cause: Internal fan fault. Internal fan not running/mounted. Remedy:
|
| 0xFF22 (0x15A) Fan lifetime critical | Cause: The theoretical lifetime of the fan has been exceeded. Remedy:
|
| 0xFF60 (0x115) Timing violation 1 | Cause: Internal timing violation detected. Remedy:
|
| 0xFF61 (0x116) Timing violation 2 | Cause: Internal timing violation detected. Remedy:
|
| 0xFF62 (0x117) Timing violation 3 | Cause: Internal timing violation detected. Remedy:
|
| 0xFF63 (0x118) Timing violation 4 | Cause: Internal timing violation detected. Remedy:
|
| 0xFF64 (0x119) Timing violation 5 | Cause: Internal timing violation detected. Remedy:
|
| 0xFF65 (0x11A) Timing violation 6 | Cause: Internal timing violation detected. Remedy:
|
| 0xFF66 (0x168) Timing violation 7 | Cause: Internal timing violation detected. Remedy:
|
| 0xFF67 (0x16B) Timing violation 8 | Cause: Internal timing violation detected. Remedy:
|
| 0xFF68 (0x16C) Timing violation 9 | Cause: Internal timing violation detected. Remedy:
|
| 0xFF70 (0x11B) Firmware: Package description mismatch | Cause: The firmware found does not match the package description. Remedy:
|
| 0xFF71 (0x11C) Firmware: Power cycle needed | Cause: The firmware update transfer is completed but a power cycle is required before the new firmware is active. Remedy:
|
| 0xFF72 (0x11D) Firmware: Update started | Cause: Firmware update is in progress. Warning changes to error when an attempt is made to enable the device in this state. Remedy:
|
| 0xFF73 (0x15B) Firmware: Update invalid | Cause: Invalid or corrupted firmware package update. Last valid firmware package has been loaded. Remedy:
|
| 0xFF80 (0x11E) STO active while drive enabled | Cause: STO activated while drive was enabled or tried to enable while STO active. Remedy:
|
| 0xFF81 (0x11F) STO mismatch | Cause: Dual diagnosis of STO voltage not plausible. Remedy:
|
| 0xFF85 (0x120) P_STO error | Cause: P_STO voltage on the power card exceeds the limits. Remedy:
|
| 0xFF90 (0x121) Guide value reversed | Cause: Position guide value went backwards while the servo drive was in CAM mode. Remedy:
|
| 0xFF91 (0x122) Guide value implausible | Cause: Increments between succeeding values too large. Remedy:
|
| 0xFF95 (0x14E) Sign of life error | Cause: Sign of life error detected. Remedy:
|
How to Clear & Reset Danfoss MSD510 Servo Drive Faults
- Fieldbus Motion Controller Reset: Command a Fault Reset over the real-time Ethernet bus (EtherCAT, POWERLINK, or PROFINET IRT) by toggling Bit 7 (Fault Reset) from `0` to `1` in the standard CiA 402 servo drive control word.
- Danfoss VLT® Servo Toolbox PC Software: Connect via Ethernet to the service interface, launch the Danfoss VLT® Servo Toolbox commissioning tool, review active module diagnostic logs, and click “Fault Reset”.
- Safe Torque Off (STO) Reset: If an STO safety event occurred, re-establish nominal 24V DC to both safety input channels (STO 1 and STO 2) on the affected module before sending a software reset command.
- Digital Input Reset (DI): If mapped in the drive configuration parameters, pulse the designated 24V DC digital input terminal on the PSM 510 power supply module or SDM axis module.
- Power Cycle (Trip Lock Clearance): For critical hardware faults, switch off the 3-phase AC mains supply to the PSM 510 power supply. Wait for the shared DC-link bus capacitors to fully discharge (minimum 5 minutes, status LEDs unlit) before re-energizing the system.
⚠️ High-Voltage Electrical Safety Warning:
Danfoss MSD 510 systems share a common high-voltage intermediate DC bus (approx. 565–680V DC) across the multi-axis backplate. Always wait a minimum of 5 minutes after completely removing AC line power and 24V control power. Confirm with a calibrated multimeter that DC voltage across the shared busbars measures strictly below 50VDC before unclipping modules or touching motor power leads (terminals U, V, W).